1 / 27

Intermec Solutions for Hazardous Environments: CK32IS

Intermec Solutions for Hazardous Environments: CK32IS. Global Considerations. Global Certification requirements . UL (Underwriters Laboratory). ATEX (European Atmospheres Explosibles Directives). IEC (International Electrotechnical Commission). Australia Singapore Malaysia Philippines

paley
Download Presentation

Intermec Solutions for Hazardous Environments: CK32IS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Intermec Solutions for Hazardous Environments: CK32IS

  2. Global Considerations • Global Certification requirements UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Australia Singapore Malaysia Philippines Indonesia Saudi Arabia European Union Norway Switzerland Turkey U.S. Canada Mexico Latvia Lithuania Luxembourg Malta Netherlands Poland Portugal Romania Slovakia Slovenia Spain Sweden United Kingdom of Great Britain and Northern Ireland Austria Belgium Bulgaria Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy

  3. Global Reach • Hazardous Environment Certifications UL, ATEX, IEC • Localized Languages English, Spanish, French, German, Italian, Simplified Chinese, Traditional Chinese, Korean, Thai (character set only) • RoHS Compliance Restriction of the Use of Certain Hazardous Substance in Electrical and Electronic Equipment • WEEE Compliance Waste Electrical and Electronic Equipment • RF Certifications • Support & Service Certified repairs at all service centers worldwide

  4. Hazardous Certifications UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Gases, Liquids, Vapors Gases, Liquids, Vapors Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Zone 0 (T4) Group IIC Zone 0 (T4) Group IIC Dusts & Fibers Dusts & Fibers Dusts & Fibers Class II Division 1 Groups E, F and G Zone 20 Group II* T250°C Zone 20 Group II* T250°C Class III Division 1 Underground Mining Underground Mining Group I M1 Group I M1 * Except conductive dust

  5. Hazardous Certifications • From concept, design specifications dedicated to meeting customer’s most stringent requirements for flammable gases, vapors, liquids, dusts or fibers. UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Gases, Liquids, Vapors Gases, Liquids, Vapors Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Zone 0 (T4) Group IIC Zone 0 (T4) Group IIC Dusts & Fibers Dusts & Fibers Dusts & Fibers Class II Division 1 Groups E, F and G Zone 20 Group II* T250°C Zone 20 Group II* T250°C Class III Division 1 Underground Mining Underground Mining Group I M1 Group I M1 * Except conductive dust

  6. High Level Device Requirements Chemical, Oil & Gas, and Pharmaceutical customers told us their “ideal” requirements: • One Device - Globally • One Manufacturer - Globally • Long Product Life Cycle • Industry Commitment - Globally • Global Technical Support & Service

  7. Detailed Device Requirements – Typical Customer • Device: Windows mobile PDA • Hazardous Ratings: • 60% - UL Class 1 Div 2 for North America • 5% - UL Class 1 Div 1 for North America • 20% - ATEX Zone 2 for Europe • 5% - ATEX Zone 1 for Europe • 10% - IEC, Rest of World (RoW) • Memory: • 128 MB of RAM / 512 MB of Flash Storage • Communications: • 802.11b/g • Cisco CCX V3 radio support • Bluetooth – Used to talk to peripherals (RFID, Vibration, Temperature probes) • Keyboard/Ergonomics: • Big, easy to use Arrows & Numeric Keys (for use in gloved environments) • User installable Trigger Handle • Support: • 8 Hours of Battery Life • No loss of data/application after cold boot • Global Support • Lock Down Application

  8. Detailed Device Requirements – What are yours? • Device? • Hazardous Ratings? • Memory? • Communications? • Keyboard/Ergonomics? • Support?

  9. Enterprise Asset Management Solutions • Example: Plant Maintenance & Repair • Trend • Good maintenance and support practices are an integral component of optimized production processes and lean manufacturing. • Key Issues • Manufacturers are focused on improving the efficiency of production. • As production capacity rises above 80% utilization, efficiency and productivity in plant maintenance and repair is mandatory. • Return on Assets (ROA) is becoming the primary driver of equipment investment. • Solutions • In-premise and extra-premise predictive maintenance. • Break-Fix operations. • Dispatching for optimized production. • Operator directed response (ODR).

  10. Intermec Hazardous Environment Solutions 751 Class I Div 2 751 ATEX Zone 2 730 Class I Div 1 CK61 Class I Div 2 CK31 Class I Div 2 CK32IS

  11. Intermec Hazardous Environment Solutions 751 Class 1 Div 2 751 ATEX Zone 2 730 Class 1 Div 1 CK61 Class1 Div 2 CK31 Class 1 Div 2 CK32IS Intermec Solutions Family Scanners Printers Mobile Computers Fixed Mount Computers RFID

  12. CK32 Intrinsically Safe Mobile Computer

  13. CK32IS Features Windows Mobile 5.0 Premium & Phone Edition & MSFP 802.11b/g WLAN w/ CCX 3, USB Bluetooth & Ethernet Intel XScale PXA270 Processor Intermec Linear Imager QVGA Color Display w/ Touchscreen 42 or 56 Keypad options(Standard, 3270/5250, VT/ANSI) 128 MB RAM 512 MB Persistent Storage Integrated Speaker/microphone

  14. CK32IS Usability • User installable trigger handle • Batteries removable in hazardous environments • Keypad options support gloved use

  15. CK32IS Accessories • Communication Adapter* • USB Client and Ethernet • Battery Eliminator • Battery Pack Option • Quad Battery Charger* • Trigger Handle • User Installable • Carrying Strap • Leather • Hand Strap • Screen Protector Kit • Tethered Stylus Kit * Associated Apparatus Certified – Guarantees that any outside equipment cannot damage the unit. Not for use in Hazardous environments.

  16. CK32IS Durability Designed from inception for exceptional durability • 5 foot drop specification • IP67 sealed • Operating temperature: -20°C to +50°C • Robust construction: • Electrostatic Dissipation • Internal Antennas • Hard Plastic Key tops • Polycarbonate Enclosure • Internal Magnesium Frame • Internal Shock Mounting • Encapsulated Circuit Boards

  17. Hardware Durability Internal Magnesium Frame • Thicker than comparable frame in standard product • Lightweight but strong • Internal skeleton

  18. Hardware Durability Magnesium frame • Reduces flexing, risk of damage • Maintains relative alignment and spacing • Protects LCD display glass

  19. Hardware Durability Encapsulated Circuit Boards • High temperature silicon for thermal insulation • Second line of protection against gas & dust • Protects components from shock, vibration, corrosion

  20. Hardware Durability Internal Shock Mounting • Isolates electronic modules • Display

  21. Hardware Durability Hard Plastic Key Caps • Laser engraved • Silicon Keypad Touch Screen Touch Screen Protector

  22. Hardware Durability Polycarbonate Enclosure • Extra thick, high quality, reinforced • Conductive IP67-rated seal Modular construction

  23. Worldwide Service & Support More than 70 service & support facilities • Local languages, time zones Medallion service contracts • Tel and web based post sales support Intermec Repair Locations Intermec Global Service Partners

  24. CK32IS Hazardous Certifications • Certified Intrinsically Safe by ALL 3 global agencies, for gases, vapors, liquids, dusts, fibers and underground mining. • Today’s safety requirements. And tomorrow’s. UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Gases, Liquids, Vapors Gases, Liquids, Vapors Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Zone 0 (T4) Group IIC Zone 0 (T4) Group IIC Dusts & Fibers Dusts & Fibers Dusts & Fibers Class II Division 1 Groups E, F and G Zone 20 Group II* T250°C Zone 20 Group II* T250°C Class III Division 1 Underground Mining Underground Mining Group I M1 Group I M1 * Except conductive dust

  25. Designed to Deliver Highest Level of Safety • Full International Safety Certifications in One Computer • Meets or Exceeds Latest Safety Standards: Zone 0 • Exceptionally Rugged: 5’ drop, IP67 • Worldwide Service & Support

  26. Next Steps • Compliance: • Define your safety certification requirements • Configuration: • Determine detailed device requirements • Service & Support: • Determine global needs

  27. Thank you! ADC Nordic - Distributor in the Nordic countries Phone +46 40-680 02 80

More Related