Martin Rottmann Dipl.-Wirt.Ing. Gebietsverkaufsleiter Mitte Nexans Cabling Solutions

Martin Rottmann Dipl.-Wirt.Ing. Gebietsverkaufsleiter Mitte Nexans Cabling Solutions. Über Nexans. Produktionsstätten in 30 Ländern und Vertretungen in 65 Ländern 22.000 Mitarbeiter weltweit 7,4 Milliarden € Gesamtumsätze in 2007 umfassende Kenntnis nationaler und internationaler Standards.

ownah
Download Presentation

Martin Rottmann Dipl.-Wirt.Ing. Gebietsverkaufsleiter Mitte Nexans Cabling Solutions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Martin Rottmann Dipl.-Wirt.Ing. Gebietsverkaufsleiter Mitte Nexans Cabling Solutions

  2. Über Nexans • Produktionsstätten in 30 Ländern und Vertretungen in 65 Ländern • 22.000 Mitarbeiter weltweit • 7,4 Milliarden € Gesamtumsätze in 2007 • umfassende Kenntnis nationaler und internationaler Standards

  3. Nexans Cabling Solution - NCS NCS Produktportfolio: • Kupfer Systemlösungen (LANmark) • F/O Systemlösungen (LANmark) • Managementsysteme(LANsense) • Schulungen • Visio Network-Planungstools

  4. GG45 – Status Quo + News Beantwortung häufig gestellter Fragen (FAQs) zum GG45™

  5. FAQ 1 ...stößt direkt zum Kern vor: „Wie funktioniert eigentlich der GG45™ und welchen Nutzen bringt er mir?“

  6. GG45™ - how it works 8 Kontakte 100% RJ45 kompatibel Schaltmechanismus nur 8 Kontakte gleichzeitig oder 2 Paare oben 2 Paare unten 1000 MHz 4 Paare oben 500 MHz 2 neue Kontaktpaare für Klasse F /Fa Anwendungen 1,2/7,8 und 3,6/4,5 1,2/7,8 und 2 neue Paare

  7. GG45™ - how it works Vier zusätzliche GG45™ Kontakte für Klasse F/ Fa Acht RJ45 Kontakte 100% Klasse D/E/Ea rückwärtskompatibel Das GG45™ Interface

  8. GG45™ - how it works Der Kat.7 Switch Das GG45™ Interface

  9. GG45™ - how it works RJ45 Modus • RJ45 Kontakte 36, 45 aktiv • Klasse F Kontakte sind aktiv, werden jedoch nicht benötigt PIMF 2+4 PIMF 1+3 Aktive Kontakte im RJ45 High Speed Modus • Stecker betätigt Schalter RJ45 Kontakte 36, 45 werden geerdet • Nur die äußeren Paare sind aktiv für Klasse F Übertragungen PIMF 2+4 PIMF 1+3 Geerdete Kontakte

  10. GG45™ - how it works Mechanical Performance of Switch 210 140 Contact Resitance on Cat.6 contacts mOhm Contact Resitance 70 on Cat.7 contacts Limit 0 0 750 1500 Insertion cycles • Überprüfung der mechanischen Performance durch ein unabhängiges Institut (Delta) • Schalterperformance: • max. Abnutzung nach 1500 Steckzyklen (Kat.7 Stecker) beträgt 9.45 m • Kontaktleistung: • keine gravierende Beeinflussung der RJ45 Steckzyklen auf Kat.7 Leistung • Keine Plastikrückstände auf Kat.7 Kontakten

  11. Vorteil: RJ45 Kompatibilität • Die GG45™ Rückwärtskompatibilität • bedeutet RJ45 kompatibel: • > mechanisch (nimmt RJ45 Stecker auf) • > elektrisch (unterstützt Cat.5 - Cat.6a • Anwendungen) • Vorteil: • > Weitere Nutzung vorhandener Patchkabel • > Unproblematische Anbindung an • vorhandenes aktives Equipment • Keine TEUREN „SPEZIALKABEL“ erforderlich • für heutige RJ45 Anbindungen – trotz 1000MHz • Class Fa Option!

  12. FAQs zum Thema GG45™ FAQ 2 ...wird (leider) immer noch gestellt...: „Ist der GG45™ eigentlich genormt? “

  13. GG45™ setzt Standards • Komponenten Standards: • IEC 60603-7-7 (rückwärtskompatibel) • Ratifizierung am 22.3.02 • PAS 61076-3-110 (nicht rückwärtskompatibel) • Ratifizierung am 23. November 2001 • Ausgewählt als Steckverbinder für Klasse F • Klasse F System Standard ISO/IEC 11801:2002 • Ratifizierung im August 09/02

  14. GG45™ GG45™ in ISO 11801 • Tabelle 28 in Klausel 10 definiert die zu verwendenden Steckverbinder

  15. Draft zu den Klasse Fa Komponenten GG45™ • Quelle : Draft ISO/IEC JTC 1/SC 25N1318A for Amendment 1.2 for ISO11801 (Link and Components)

  16. FAQs zum Thema GG45™ FAQ 3 ...beschäftigt sich mit der Vergangenheit: „Hat der Investitionsschutz von GG45™ in der Vergangenheit funktioniert?“

  17. 10GBase-T...schon ein Rückblick ;-) 0 -10 -20 Klasse E -30 ISO11801 2te Ausgabe Attenuation Channel Klasse E -40 ISO11801 New Amendment Klasse E TSB-155 IEC 24750 NEXT GG45™ Dämpfung NEXT [dB] -50 GG45™ NEXT -60 ISO11801 New Amendment Klasse E Relaxed NEXT -70 -80 -90 -100 0 100 200 300 400 500 600 700 800 900 1000 ACR im Vergleich GG45TM Frequenz [MHz]

  18. 10GBase-T • Klasse F erfüllte von Anfang an alle Anforderungen für 10G • Frequenzbereich, Channel, Alien Crosstalk… Und ist standardisiert: • GG45™ ist der einzige RJ45 kompatible Steckverbinder, der oberhalb 250 MHz die Komponentennorm erfüllt • Alle Kunden von GG45™ haben garantierten Support der endgültigen 10 GBase-T Applikation • Gültig für Alt-Kunden und Neu-Kunden !! • Der Investitionsschutz von Klasse F hat funktioniert (im Gegensatz zur “Klasse E”)

  19. Störleistungsunterdrückung GG45 Keine Alien NEXT Messungen erforderlich • ISO11801 Amend.1 macht Alien NEXT Messungen abhängig von ‘Coupling Attenutation’ (CA): wenn ‘CA’ Anforderung erfüllt ist, dann ist Alien Next „met by design“ • CA von 56dB entspricht ca. 10 dB Reserve ISO11801 Amend.1:“If coupling attenuation for class EA or F channels is better than 90-20log(f) ….then PSANEXT and PS AACR-F are met by design”.

  20. FAQs zum Thema GG45™ FAQ 4 ...beschäftigt sich mit der Zukunft: „Welchen Investitionsschutz bietet GG45™ heute noch“?

  21. Die neue Oberklasse: Fa • New LAN Standards für Class Ea und Class Fa • Class Ea geht von 250 MHz nach 500MHz • Class Fa geht von 600 MHz nach 1000MHz

  22. GG45™ – the next Generation • Neu: das LANmark 7a System • 2-in-1 Buchse: Rückwärts kompatibel (RJ45 Modus) Support künftiger 40 Gig Anwendungen (GG45 Modus) Support: von Energy Efficient Ethernet • Doppelte Bandbreite bei halbem Nebensprechen (Vergleich mit Class Ea) LANmark 7a

  23. GG45™ und Klasse Fa Klasse Fa Performance ist bestätigt durch unabhängiges Messinstitut • 4 Connector Channel Konfiguration • Alle 4 Verbindungspunkte mit ‚schaltbarem‘ GG45™

  24. Doppelte Bandbreite -halbes Nebensprechen

  25. Shannon Kapazität • das LANmark-7a System liefert eine Shannon Kapazität von 52 Gbps • Übereinstimmende Resultate verschiedener internationaler Nexans Study Groups – aber auch externer Untersuchungen * LANmark Channels have headroom built in to deliver extra capacity above minimal requirements from standards

  26. das Pennstate Modell Shannon Capacity Calculation Shannon Capacity Calculation CAT - 7a 100m Bkgd noise only NEXT, FEXT and Echo cancelled by 50,42,53dB Bkgd noise only NEXT, FEXT and Echo cancelled by 50,42,53dB 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12 Gbits/s Gbits/s 10 10 Gbits/s Gbits/s 10 10 8 8 8 8 Capacity Capacity Capacity Capacity Water-filling bound 6 6 Water-filling bound Water-filling bound 6 6 Water-filling bound Single carrier bound Single carrier bound Single carrier bound Single carrier bound 4 4 4 4 2 2 2 2 0 0 0 0 0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000 MHz MHz MHz MHz Optimum BW ? 1.8GHz l N0= - 165 dBm /Hz, P =+10dBm l 8 t 13Gbps je Paar bei 1GHz • das Diagramm zeigt Kapazität je Paar und Frequenz • Bestätigt 13G je Paar x 4 = 52 Gbps • Kapazität sogar > 60GBps

  27. wann kommt 40GBase-T?eine Einschätzung der ComConsult Research Dr. Kauffels im ComConsult Netzwerk Insider Jan/2009: „Der GG45-Stecker passt zu Cat 7A-Kabeln.“ „Der ANEXT-Wert ist sensationell.“ (mit Bezug auf LANmark-7A) „Bis vor Kurzem konnte niemand sagen, ob eine 40 Gig Variante auch auf Twisted Pair möglich ist. Das hat sich mittlerweile geändert, es wird definitiv 40 GBASE-T geben.“ „40 GBASE-T wird ab 2009 von der Standardisierung aufgenommen, es gibt schon passende Kabel und Stecker, das geht dann schnell.“

  28. FAQs zum Thema GG45™ FAQ 5 ...beschäftigt sich mit der Zukunft: „GG45™ unterstützt also 40Gig – lässt sich der Headroom auch anders nutzen?“

  29. Green Cabling ? • Wie kann ein Kat. 7a Verkabelungssystem zur “Green-IT” beitragen ? • Themen sind hier natürlich Bleifreiheit , Übereinstimmung mit ROHS, umweltfreundliche Verpackung etc.. • ...also Themen, die nichts mit der Performance zu tun haben... • IT = Stromverbrauch = CO² Ausstoß = KOSTEN! • Zwischen dem Stromverbrauch und der Performance gibt es einen Zusammenhang: • die ACR Werte einer Verkabelung bestimmen den Grad der benötigten Chip Komplexität • das hohe ACR der Kat.7a gestattet eine geringere Chip Komplexität und damit neue Chip Designs mit geringerem Strom Verbrauch!

  30. Green Cabling – Beispiel: 10G • zum Herausrechnen von Echo, NEXT, und FEXT werden rund 40% des Stromverbrauchs benötigt 40% 10G wurde auf Basis des Cat.6a ACR entwickelt; bei Zugrunde-legung der Cat.7a Performance könnten bis zu 40% des Stromver-brauchs potentiell gesenkt werden!

  31. Next Generation Initiatives (IEEE) • Initiativen für Neue Applikationen werden vorangetrieben durch • die Ziele des Energy Efficient Ethernet (EEE) • U.S. Federal Executive Order 13423 • U.S. Green Building Council (USGBC) • Ziele: • Senkung des Stromverbauchs • Senkung der Latenzzeiten • Cat.7a bestens geeignet diese Ziele zu unterstützen • Cat.7a ist “grüner” als Cat.6A Nur, wer heute nach Cat.7 /7a verkabelt, kann später seine Energiekosten durch den Einsatz von Energy Efficient Ethernet Aktivkomponenten senken!

  32. FAQs zum Thema GG45™ FAQ 6 ...interessiert Planer und Installateure: „ ...mit welchen Geräten kann man den GG45™ im Feld messen“

  33. GG45 Feldmessung

  34. FAQs zum Thema GG45™ FAQ 7 gestellt von der Mehrheit der IT-Endscheider: „Alles eine Kostenfrage: vielleicht doch besser erst Kat.7 Kabel verlegen mit RJ45 Buchsen?“

  35. Cat.7 + 6 Mix + Match...späteres Upgrade? Kostenverteilung Erstinstallation Standard Verkabelung in D: Kat.7 Kabel und Kat.6 Buchsen

  36. Cat.7 + 6 Mix + Match...späteres Upgrade? Kostenverteilung Upgrade der Buchse Kostenverteilung bei späterem Upgrade Ein Upgrade /Austausch kostet noch mal 60% der Erstinstallation

  37. GG45™ vs. Cat.7 + 6 Mix & Match GG45™... ...erspart die Kosten eines späteren Buchsen-Upgrades ...keine Ausfallzeiten durch Neumontage ...stellt sofort mehr Performance zur Verfügung Eine sofortige GG45™ Verkabelung kostet ca. 40 % mehr...

  38. Performance Vergleich: AWG22/RJ45 vs. GG45™ Class FA LIMIT 2 Connector Channel Att LM7A 1200 2m-90m-2m NEXT AWG22 1500 120 Att AWG22 1500 Att EA LM7A 1200 ATT EA LM7A 1500 NEXT EA LM7A 1200 100 NEXT EA LM7A 1500 NEXT LM7A 1200 Att NCS1200 ...und: Nur mit einer durchgängen Class Fa Verkabelung läßt sich die Güte der Links im hohen Frequenzbereich messen! Bei Cat.7 Kabel + RJ45 Links bleibt die Performance oberhalb Cat.6a im Dunkeln 80 60 Performancegewinn durch Cat 7 Steckverbinder: 20dB 40 Performancegewinn durch gutes Cat7 Kabel: 3.5dB 20 0 0 100 200 300 400 500 600

  39. FAQs zum Thema GG45™ FAQ 8 ...von denen, die noch mehr in die Zukunft schauen: „Wann kommen aktive Geräte mit GG45 „Interface ?“

  40. Kooperation Nexans/BelStewart • Gegenstand der Kooperation • Entwicklung von Kat.7 Leiterplatten-Modulen für Aktiv-Gerätehersteller (8 Kontakte) • Entwicklung und Produktion von Low-Cost Kat7 Steckern • Sicherstellung der Interoperabilität zwischen den Produktreihen • Produktion und Vermarktung der Produkte erfolgt unabhängig Bild: LANmark-7a GG45 8c

  41. Roadmap Cat.7 Geplant Real Schritt 1: Klasse F Standard wird veröffentlicht 2002 2002 Schritt 2: Produkte sind verfügbar 2002 2002 Schritt 3: Marktakzeptanz 2004 2005/6 Schritt 4: Anwendungsstandards erscheinen 2010 2007 Schritt 5: Aktive Geräte erscheinen 2012 ? „Ach, daß der Mensch so häufig irrt und nie recht weiß, was kommen wird.“ W. Busch

  42. Next Generation 10G Switche • SMC Networks wird 2009 sein Angebot an 10G-Switches ausweiten und um einen 10G-Switch mit 24 Ports für Kupfernetze (Cat 7) ergänzen.

  43. Zusammenfassung • GG45™ hat eine steigen Marktakzeptanz • „ 2 in 1“ Design spart Kosten (Patchcords, späteres Buchsen-Upgrade...) • Investitionschutz von GG45™ hat funktioniert • Messtechnische Überprüfung des Links oberhalb Cat.6a • Unterstützung künftiger 40G Protokolle • Unterstützung künftiger Energy Efficient Ethernet Komponenten zur Senkung der Energie Kosten • Entwicklung aktiver Geräte mit GG45™ Interface wird unterstützt

  44. Danke für Ihre Aufmerksamkeit! Weitere Informationen unter www.nexans.com/lansystems www.ksi.at Fragen?