1 / 13

Data Acquisition Systems for Future Calorimetry at the International Linear Collider

Data Acquisition Systems for Future Calorimetry at the International Linear Collider. Matt Warren, on behalf of CALICE-UK Collaboration. Introduction. Building a DAQ for multiple ILC CAL sub-detector prototypes Paying attention real ILC environment

orien
Download Presentation

Data Acquisition Systems for Future Calorimetry at the International Linear Collider

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Data Acquisition Systems forFuture Calorimetry at theInternational Linear Collider Matt Warren, on behalf of CALICE-UK Collaboration

  2. Introduction • Building a DAQ for multiple ILC CAL sub-detector prototypes • Paying attention real ILC environment • EUDET Testbeam in 2009! (EU funded DETector project shares much of CALICE) • For economies of scale, we are attempting a generic DAQ for many (even SLHC??) • Modular/Generic Structure: • Generic readout system as much as possible • Detector specific interfaces only at ends of chain • Other ‘bespoke’ functionality in firmware • Commercial components and protocols where possible • Readout links use standard connectors and protocols • Based on PCs with PCIe cards (“backplaneless”) • Clock and Control attempts commercial hardware too • Extract clock and ‘fast’ signals from commercial signalling • Software generic for all detectors • Try use something off-the-shelf … BUT first, an introduction to the ILC CAL … Matt Warren - DAQ for Calorimetry at ILC

  3. Time structure of bunches Trains of bunches Individual bunches ILC Calorimetry • ILC Calorimetry is dense and high granularity • squeezed between large tracker & expensive coil • >100M channels • No room for electronics or cooling. • Bunch structure interesting: • ~200ms gaps between bunch-trains • Trains 1ms long, 300ns bunch spacing • Triggerless – sample data from every bunch-crossing SO (the problem): • 100M channels, analog signals = front-end electronics inside detector • Results in high power density • but no room for cooling • Long gap allows chips a 1% duty cycle Solution: Power Pulsing HCAL ECAL M. Anduze Matt Warren - DAQ for Calorimetry at ILC

  4. Sub-Detector Geometries (+ASICs) ASICS • Must share readout resource (daisy chain) • Bunch rate too high for instantaneous data transfer. • Too much chip resource to store all events SO: • ‘Auto-trigger’ – store only data over-threshold with pad id + (bunch-number) • <5kByte / bunch-train/ASIC HCAL half-octant ECAL Module-0 (reduced-Z octant) M. Anduze L = 150 cm ASIC (>100 in total!) Detector Unit (e.g. ECAL Slab) Matt Warren - DAQ for Calorimetry at ILC

  5. Host PC Host PC ODR ODR PCIe PCIe DIF DIF DIF DIF Detector Unit Detector Unit Detector Unit Detector Unit DAQ architecture Detector Unit:Sensors & ASICs DIF: Detector InterFace -connects generic DAQ and services LDA: Link/Data Aggregator – fanout/in DIFs & drive link to ODR ODR: Off Detector Receiver – PC interface for system. C&C: Clock & Control: Fanout to ODRs (or LDAs) 50-150 Mbps HDMI cabling 1-3Gb Fibre LDA C&C Counting Room Detector Storage LDA 10-100m 0.1-1m Matt Warren - DAQ for Calorimetry at ILC

  6. DIF (Detector InterFace)  DAQ • FPGA + detector hardware connected to Detector Unit. • Two halves – Generic DAQ and Specific Detector • 3 detectors: ECAL, AHCAL, DHCAL • 1 DAQ Interface! Focusing on the DAQ side: • From LDA, receive, decode/regenerate and distribute clocks, fast commands, config data and slow controls. • From ASICs, receive, buffer, package and forward data to LDA • ASICs power-up and read-out power-down in turn • ALSO: USB interface • Hardware designers already have one • DAQ plans to integrate for stand-alone testing DIF Detector Unit USB M. Goodrick e.g. ECAL Matt Warren - DAQ for Calorimetry at ILC

  7. DIF DIF DIF DIF Detector Unit Detector Unit Detector Unit Detector Unit DIF-LDA link • Serial links running at multiple of machine clock • ~50Mbps (raw) bandwidth minimum • robust encoding (8B/10B) • HDMI cables/connectors interface. • Commercially available cables • Rated >300Mb • Even halogen free available • Signals (ideally just TX/RX but …): Clock (diff) Control/Fast (diff) Very Fast (diff) Data (diff) single ended aux x2 (or UTP) • LDAs serve even/odd DIFs for redundancy LDA LDA Matt Warren - DAQ for Calorimetry at ILC

  8. LDA (Link/Data Aggregator) • Located as close as possible to DIFs • Shortest cables, but convenient location (space, cooling) • Supports as many DIFs as possible considering bandwidth and physical constrains • Ideally 50 (20Mbps/DIF) • Prototype will have 10 • Aggregates front-end data and sends it off-detector • Fibre optic link. 1-3Gbps, with SFP (see next slide) • Fanout C+C+C to DIFs • USB interface for stand-alone/top-of-chain testing LDA LDA • Currently using a commercial FPGA dev-board: Enterpoint Broaddown2 – Xilinx Spartan3-200 • With add-on boards for our needs • SPF+SerDes for ODR link • 10 HDMI connectors with clock fanout Matt Warren - DAQ for Calorimetry at ILC

  9. Host PC ODR PCIe ODR (Off Detector Receiver) + Link • Receives module data from LDA • PCI-Express card, hosted in PC. • 1-4 links/card (or more), 1-2 cards/PC • Buffers and transfers to store as fast as possible • Fibre optic link to detector via SFP modules (std networking hw) • Currently GigE (1.25Gb), but could higher and use different proto. • Sends controls and config to LDA for distribution to DIFs • Interfaces to C+C for synchro running • Goal to send clock and prompt controls over optic link too • Reset and reprog FPGAs • Performance studies & optimisation on-going (see next slide): • Bottleneck in writing data to disk. C&C Storage Expansion (e.g. 3xSFP) SFPs for optic link Hardware: • Using commercial FPGA dev-board: • PLDA XPressFX100 • Xilinx Virtex 4, 8xPCIe, 2x SFP (3 more with expansion board) • Our own firmware and Linux driver software Matt Warren - DAQ for Calorimetry at ILC

  10. ODR Throughput Measurements • All measurements: single requester thread, single IO thread (disk write), • Each event fragment written to a separate file. Data written to the localdisk (fs: ext3) • e.g. WORST CASE! ` Ethernet frame size Problem with test! A. Misiejuk NDG – Network Data Generator IDG – Internal (ODR) Data Generator NDG plot – between two separate machines, Gigabit, copper Eth on both sides Matt Warren - DAQ for Calorimetry at ILC

  11. Host PC Host PC ODR ODR PCIe PCIe Clock & Control • C&C unit provides machine clock and fast signals to 8x ODR/LDA. • Logic control (FPGA, connected via USB) • Command encoders • Remote signal enable, clock selection • But capable of stand-alone, dumb mode • Provision for async scintillator type signals (VFast) • LDA provides next stage fanout to DIFs • Eg C&C unit -> 8 LDAs -> 10 DIFs = 80 DUs. • Signalling over same HDMI type cabling • Facility to generate optical link clock (~125-250MHz from ~50MHz machine clock) LDA Machine C&C Run-Control LDA • Commercial systems are not ideal here. • Looking at custom protocol on fibre optic link • Prompt signals and low jitter clock recovery needs further investigation Matt Warren - DAQ for Calorimetry at ILC

  12. Software and Operation Software: Looking for OTS software to cover both slow and fast controls: Early days – examining EPICs, ACE and DOOCS (the current favourite) - DOOCS is open source, actively developed, slow and fast controls, and already used by ILC community Operation: Two modes: 1) Configure: PCs controlled over network to send configuration to LDAs and DIFs 2) Run: • LDA/DIF set to data-taking mode • ODR configured for data reception, control handed to central. OR ODR needs no control – simply waits • Bunch-train starts/stop signals sent to LDAs control data flow. Fairly autonomous system (i.e. no trigger!) Matt Warren - DAQ for Calorimetry at ILC

  13. Summary (an example – AHCAL) Off-Detector DAQ LDA DIF Detector Unit P. Göttlicher, DESY Matt Warren - DAQ for Calorimetry at ILC