1 / 9

Valveless “LIVE” Column Switching

Valveless “LIVE” Column Switching. s. MAY-02. 0 | 8. 3. 1. 2. EPC 1. EPC 2. 4. 3. 2. 1. Pre Column. Main Column. Detector. 4. Needle Valve or Restrictor. Needle Valve or Restrictor. Split & Backflush Vent. Vent or Detector. Valveless Column Switching BACKFLUSH.

oren
Download Presentation

Valveless “LIVE” Column Switching

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Valveless “LIVE” Column Switching s MAY-02 0 | 8

  2. 3 1 2 EPC 1 EPC 2 4 3 2 1 Pre Column Main Column Detector 4 Needle Valve or Restrictor Needle Valve or Restrictor Split & Backflush Vent Vent or Detector Valveless Column SwitchingBACKFLUSH BACKFLUSH “Cross” Coupling Piece Backflush: EPC 1 Constant: EPC 2 MAY-02 1 | 8

  3. EPC 1 EPC 2 EPC 2 EPC 1 Ambient Ambient Valveless Column SwitchingBACKFLUSH BACKFLUSH Backflush Off: From Pre to Main column Backflush On: Pre Column flow reversed Backflush On: Backflush Pre Column EPC1 < EPC 2 Backflush Off: Pre to Main Column EPC1 > EPC 2 MAY-02 2 | 8

  4. 6 3 2 1 4 EPC 1 EPC 2 EPC 3 5 3 5 1 2 Pre Column Main Column Detector 4 6 Needle Valve or Restrictor Needle Valve or Restrictor Split & Backflush Vent Vent or Detector Vent or Detector Valveless Column SwitchingBACKFLUSH & HEART CUT BACKFLUSH & HEART CUT LIVE-T-Coupling Piece Backflush: EPC 1 Heart CUT: EPC 2 Constant: EPC 3 MAY-02 3 | 8

  5. Valveless Column SwitchingBACKFLUSH & Heart Cut EPC 2 EPC 3 BACKFLUSH & HEART CUT LIVE-T-Coupling Piece Backflush: EPC 1 Heart Cut: EPC 2 Constant: EPC 3 Seal Transfer Capillary Pre Column Main Column Cut to Vent / Detector Purge to Vent / Detector MAY-02 4 | 8

  6. EPC 2 EPC 3 Pre Column Main Column Cut to Vent / Detector Purge to Vent / Detector EPC 1 EPC 3 EPC 2 Ambient Valveless Column SwitchingBACKFLUSH & HEART CUT CUT TO VENT: EPC 2 < EPC 3 MAY-02 5 | 8

  7. EPC 2 EPC 3 Pre Column Main Column Cut to Vent / Detector Purge to Vent / Detector EPC 1 EPC 2 EPC 3 Ambient Valveless Column SwitchingBACKFLUSH & HEART CUT PRE TO MAIN COLUMN EPC 2 > EPC 3 MAY-02 6 | 8

  8. EPC 2 EPC 3 Pre Column Main Column Cut to Vent / Detector Purge to Vent / Detector EPC 1 EPC 2 EPC 3 Ambient Valveless Column SwitchingBACKFLUSH & HEART CUT BACKFLUSH EPC 1 < EPC 2 MAY-02 7 | 8

  9. 6 3 2 1 4 EPC 1 EPC 2 EPC 3 5 Detector 3 5 1 2 Pre Column Main Column 1 4 6 Main Column 2 Needle Valve or Restrictor Needle Valve or Restrictor Detector Split & Backflush Vent Vent or Detector Valveless Column SwitchingBACKFLUSH & DISTRIBUTION BACKFLUSH & DISTRIBUTION LIVE-T-Coupling Piece Backflush: EPC 1 Distribution: EPC 2 Constant: EPC 3 MAY-02 8 | 8