1 / 12

JM RhinoPlate Overview

JM RhinoPlate Overview. INDUCTION Electromagnetic induction is an invisible force used to generate heat in a conductor. This heat can be used to activate a powerful bond between thermoplastic roofing materials and coated plates, without penetrating the membrane

oral
Download Presentation

JM RhinoPlate Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JM RhinoPlate Overview

  2. INDUCTION Electromagnetic induction is an invisible force used to generate heat in a conductor This heat can be used to activate a powerful bond between thermoplastic roofing materials and coated plates, without penetrating the membrane Induction heating is used safely in many industrial and consumer applications JM RhinoPlate Roofing Concept

  3. Components • RhinoPlate Welder • Magnetic cooling clamps • Set of 6 / tool • JM RhinoPlates • TPO • JM Roofing Fasteners

  4. Install Insulation… screw down with coated RhinoPlates Roll out the Membrane… Weld Seams… with standard tool Attach Field… at each insulation fastener with RhinoBond tool Clamp In Place… squeeze membrane – only 1 minute and its totally secure Five Steps to a Better Roof

  5. System Comparison Traditional System 10’ Roofing Membrane: field 5’ Roofing membrane: 15’ from parapet in perimeter zone. Insulation attachment: 6/per board using standard plate Membrane attachment: Seams mechanically Fastened 6” O.C. Seam attachment; Heat welded end laps Corner zone attachment: Half-sheets and additional fastening required in corners Meets FM 1-90 requirements RhinoplateSystem 10’ Roofing Membrane: field and perimeter zones Insulation attachment: 6/board using Rhinoplate Membrane attachment: Membrane inducted to Insulation plates Seam attachment: Heat welded end laps Corner zone attachment: Additional plates required in insulation only. Meets FM 1-90 requirements

  6. JM RhinoPlate Advantages • No seam fasteners / No penetrations • No half sheets / Fewer seams • 25-50% fewer fasteners • Best in class wind uplift resistance • Dry-in larger areas faster • Even load distribution • Reduced flutter (not dependent on sheet width) • Great looking roof!

  7. The JM RhinoPlate Advantage RhinoPlatedistributes wind loads evenly across the roof

  8. High Performance RhinoPlateresists over 500 pounds of force

  9. Performance is Proven UEATC and Dynamic Testing

  10. No adhesives… eliminates solvents and pollutants No fumes… stops complaints from people using the facility No hazardous materials… Removes logistics hassles storing flammables RhinoPlateis SAFER &GREENER

  11. Reduces fasteners Eliminates half sheets Gets rid of flutter Drys-in faster Works from 0 - 120F Environmentally friendly JM RhinoPlateRecap

  12. Thank you