1 / 7

FLOW measurement with V0 Detector

FLOW measurement with V0 Detector. Flow in Heavy ion collision. A geometry shape of overlap region may generate collective motion in particle production Particle distribution in transvers direction with Fourier transformation called FLOW. Event plane Method.

ophira
Download Presentation

FLOW measurement with V0 Detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FLOW measurement with V0 Detector

  2. Flow in Heavy ion collision • A geometry shape of overlap region may generate collective motion in particle production • Particle distribution in transvers direction with Fourier transformation called FLOW

  3. Event plane Method • One way to measure this FLOW value is Event plane method. • In EP method, measure event plane with Flow Q-Vector and calculate observed FLOW value(Vn^obs) and corrected by Resolution

  4. EP Method in ALICE • And past HIM meeting 2012 @ Pyungchang, Myunggeun Song shows, Event Plane measurement with V0 detector which place in forward direction can remove non-flow effect from jet • But measure event plane with V0 detector can cause another problem related to resolution. Because V0 detector has only 8 sector in azimuthal direction. • And, in EP method, if resolution is not perfect, Flow value is not <Vn>. It is somewhat between <Vn> and rms of Vn

  5. SP Mehtod • To solve this problem, we introduce Scalar Product Method which is advanced method of EP method • In this method, we use magnitude of flow vector when calculated FLOW

  6. AMPT Simulation result • Before detector smearing (High resolution) • Error is not calculated • Use 2sub event method to calculate resolution • Result with SP Method and EP Method are almost same

  7. AMPT simulation result • After detector smearing (low resolution) • Error is not calculated • Use 2sub event method to calculate resolution • Result with SP method is about 10% lower then result of EP method

More Related