Control and Monitoring of Front-end and Readout Electronics in ALICE. Peter Chochula. Outline. Front-End and ReadOut electronics (FERO) access strategy will be described using SPD as an example Live demonstration of a prototype solution Discussion of related problems

Download Presentation

Control and Monitoring of Front-end and Readout Electronics in ALICE

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Control and monitoring of front end and readout electronics in alice

Control and Monitoring of Front-end and Readout Electronics in ALICE

Peter Chochula


Outline

Outline

  • Front-End and ReadOut electronics (FERO) access strategy will be described using SPD as an example

  • Live demonstration of a prototype solution

  • Discussion of related problems

    This is not a first presentation on FERO problematics. Proposed solution should now be adopted as ALICE standard – your feedback is therefore essential.

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Basic interaction between fero and dcs

Basic Interaction Between FERO and DCS

  • FERO controls ranges from downloading of parameters to high-level tasks such as calibration

  • Monitoring includes direct reading of parameters provided by the electronics or indirect surveillance using associated equipment (power supplies etc.)

  • Corrective actions are expected from the control system in case of anomalous values (errors, excessive readings etc.)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


The front end device fed

The Front-end Device (FED)

  • The FED makes implementation details transparent to higher software layers

  • FED encapsulates hardware and software into a unit

    • Accepting standard and detector specific commands

    • Publishing standard and detector specific data

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Fero control and monitoring strategies in alice

Class B

Class C

Class D

Class A

  • alternative technology such as Profibus, Ethernet, Easynet etc. is used to configure FERO

  • FERO configuration can be performed via DDL and optionally using alternative techno-logy (Profibus, Ethernet, etc.)

  • FERO configuration is implemented via DDL

  • Monitoring is based on different technologies

  • Configuration and Monitoring are sharing the same access path to FERO

Configuration

Configuration

Configuration

Monitoring

Monitoring

Monitoring

Configuration

Monitoring

Non-DDL

technology

Non-DDL

technology

DDL

DDL

FERO

FERO

FERO

FERO

FERO Control and Monitoring Strategies in ALICE

  • Four different FERO architecture classes should be transparent to upper software layers

  • FERO should be treated as any other device:

    • accept commands

    • publish status and gathered data

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


The front end device fed1

The Front-end Device (FED)

DAQ/RC

DCS

Class A+B Control

FED Client

DDL SW

Monitoring of all classes

FED

Communication based on DIM

DDL SW

FED Server

Control CPU

Control CPU

Profibus, JTAG, etc.

DDL

FERO Hardware Layer

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


The front end device fed2

The Front-end Device (FED)

Class B,C,D Control

DAQ/RC

DCS

Class A+B Control

FED Client

DDL SW

Monitoring of all classes

FED

DDL SW

FED Server

Control CPU

Control CPU

Profibus, JTAG, etc.

DDL

FERO Hardware Layer

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


The front end device fed3

The Front-end Device (FED)

ECS

Class B,C,D Control

DAQ/RC

DCS

Class A+B Control

FED Client

DDL SW

Monitoring of all classes

FED

DDL SW

FED Server

Control CPU

Control CPU

Profibus, JTAG, etc.

DDL

FERO Hardware Layer

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Spd readout architecture

SPD Readout Architecture

DCS

DAQ

VME Router Card

PCI-MXI-II-VME

JTAG, CLK, Detector Data

Trig

~100m

1 router services 6 halfstaves

SPD contains 20 routers

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Alice spd as an example for fed implementation

MCM

ALICE SPD as an example for FED Implementation

Basic SPD block seen by online systems is a half stave

Laser and Pin Diodes

  • GOL - Translates data into G-Link compatible 800Mbit/s stream and drives the optical laser component

Digital Pilot –receives trigger signals, controls chips, reads analog pilot

Analog Pilot – provides reference voltages, ADCs for monitoring

ALICE1/LHCB Chip – reads signals from bump-bonded pixel sensors

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Spd operation modes

SPD Operation Modes

  • Configuration Mode:

  • JTAG Bus is used to configure ALICE1 chips

  • Monitoring of MCM is suspended

JTAG

  • Operation Mode:

  • ALICE1 chips are taking data

  • JTAG Bus is reconfigured and services only the MCM

  • MCM is monitored via JTAG

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Monitoring of alice spd

Monitoring of ALICE SPD

Monitoring Commands

Data (Temp,I,V,flags)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Configuration of alice spd

Configuration of ALICE SPD

New Configuration Data

Current Configuration Data

New Configuration Data

CONFIGURING !

Old Data Output

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Implementation of spd fero control

Implementation of SPD FERO Control

  • Application called “SPD FED Server “ written in C++ (WXP)

  • Various tasks implemented as threads

    • Configuration

    • Monitoring

    • Readout tests, etc…

  • Operation of threads is synchronized by the main application

  • The threads are called AGENTS

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Spd agents

SPD Agents

SPD FED SERVER

Monitoring Agent

(MA)

Control Agent

(CA)

During the execution of control task the

operation of MA must be suspended

Monitoring Agent continuously

reads the MCM parameters

The MA is allowed to

resume its operation

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Architecture of spd control and monitoring software

Architecture of SPD Control and Monitoring Software

Client

Software

(PVSS) DIM Client

Commands

Data

Monitoring Agents (MA) are implemented as separate threads

DIM server

FED

Server

CA1

Database

CA2

MA1

MA1

VISA

PCI-MXI-VME

Control Agents (CA) react to commands received by the server

Monitoring Agents (MA) publish data as DIM services

Router

SPD Halfstave MCM

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Generic architecture of the fed software

Generic architecture of the FED software

DIM Interface allows for communication with higher levels of software

Client

Software

(PVSS) DIM Client

Commands

Data

DIM server

FED

Server

Application layer contains detector control and monitoring code (agents)

CA1

Database

CA2

MA1

MA1

Device driver(s)

Hardware

Hardware access layer contains device drivers

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Spd fed server

SPD FED Server

  • SPD FED Server is one and only access point to the hardware

  • FED server accepts commands and executes them

    • It arbitrates access to the hardware

    • Synchronizes internal execution of agents

  • Main (DCS) role of the server is monitoring of sensitive detector parameters

    • Acquired data is published as service

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Fed server commands and services

FED Server commands and services

  • The communication can be divided into standard and sub-detector specific parts.

  • Standard commands include setup and monitoring of the FED servers itself, initialization and actions common for all architectures

  • SPD specific part includes procedures used only by SPD

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Dim interface of the spd c m server

Recognized commands

General:

Initialize

Re-initialize

Calibrate

Modify Running parameters

Publish Active Settings

SPD Specific

Test Readout

Test JTAG

Test SEU

Start/Stop Agents

DIM Interface of the SPD C/M Server

Published services

  • General:

    • Server Status

    • Agent Status

    • Messages

  • Detector data:

    • Temp

    • I, V

    • Status and error flags

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Fed server operation

FED Server operation

  • The server needs to be first configured (there are standard built-in settings). This includes:

    • Setting of logging method

    • Setting of readout frequencies for the agents

    • Setting of deadbands for the agents

  • On request the agents start their operation. States of individual agents are visible to all server components and are used for internal synchronization

  • Monitoring agents typically read data in predefined intervals (auto-triggering). External triggers are possible

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Spd agent states

SPD Agent States

  • The agent accesses the hardware and performs its task (FERO configuration, DCS data readout, etc.)

  • The agent fully relies on main thread – during its execution all potentially interfering agents must be suspended. Status of other threads is signaled to individual agents.

  • Execution of complex agents can be interrupted by external command (e.g. calibration run can be stopped and FERO can be reloaded)

Executing

Execute (or auto-trigger)

Idle/Alive

  • The agent is ready and waits for command or auto-trigger

  • Idle agent sends heartbeat to the main thread

  • The agents are suspended at server’s startup time (to avoid interference e.g. during crash recovery when the state of bus is not known)

  • Agents can be suspended also on request (e.g. to disable auto-triggering for a short period)

  • On wakeup the agent automatically resumes its previous task

Suspend

Wakeup

Suspended

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Live demonstration

Live demonstration


Fed server setup

FED Server Setup

Server Operation Parameters

Debugging Level Control

Debugging Output Control

Internal Agent Status Monitoring Settings

  • The Server Setup Panel allows tuning of server operation and debugging

    • sets monitoring limits and refresh rates

    • controls complexity of published messages

    • controls publishing of debugging informatio

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Fed server control

FED Server Control

  • Server Status Info:

  • Operational

  • Initializing

  • Calibrating

  • Checking JTAG

  • …..

Server Commands

  • Agent Status Info:

  • Suspended

  • Executing

  • Idle

  • The Server Control Panel allows sending commands to the FED

  • On receipt of command C/M Server:

  • Suspends monitoring agents (if needed)

  • Performs requested task

  • Resumes agent operation

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Messenger service and message viewer

Mesage

Severity

Time & Date

Caller

Detector

Example of PVSSII Message Viewer

(based on DIM service)

Messenger Service and Message Viewer

  • Messenger Service provides information about server’s operation

  • Complexity of published messages can be remotely tuned

  • Message destinations:

    • DIM based viewers

    • Logfiles/screen

    • Windows Event Logger (ActiveX)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Detector data subscriber

Detector Data Subscriber

PVSSII is the main DCS operation tool

PVSS client subscribes to data published by the C/M server

Gathered data is treated according to DCS recipes

Data in this panel is updated according to server settings (frequency,deadbands, etc..)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Automatic evaluation of communication status

Automatic evaluation of communication status

Server operational but no data published

Connection to Server lost!

OK

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


End of demonstration

End of demonstration


Optional dim clients

Optional DIM clients

  • Although PVSSII is the main DCS operation tool, it is not required to have it running in order to monitor data provided by the C/M Server

  • Additional clients such as Custom C++ clients, DimTree or DID can connect to C/M server in parallel to PVSS client

  • Operation of custom clients presents a serious risk to the DCS and their use will be strictly forbidden during running. The usage of extra clients will be allowed only for monitoring purposes.

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Live demonstration of optional dim clients

Live demonstration of optional DIM clients


Integration of fed with dcs

Integration of FED with DCS

  • FED can be described in terms of state machines and integrated with DCS using SMI++ interface

  • The aim is to identify common operational aspects and set them as ALICE standard.

  • Each detector will use its additional specific states

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Modelling the fed as a fsm standard part

Modelling the FED as a FSM : standard part

RUNNING

Stop

Run

READY

Re-Initialize

Initializing

Go STDBY

STANDBY

Initialize

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Modelling the fed as a fsm sub detector specific the ready state is taken from precious example

Modelling the FED as a FSM : sub-detector specific (the READY state is taken from precious example)

Calibrating

Checking SEU

Check SEU

Calibrate

READY

Check JTAG

Check Readout

Checking JTAG

Checking R/O

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Applications of described approach outside the fero domain

Applications of described approach outside the FERO Domain

In principle the described concept can be used to access any equipment requiring remote supervision

DIM

DIM

C/M

C/M

VISA

VISA

RS-232

RS-232 or Ethernet

Stepper Motor

Controller

Non-standard

Power Supply

Mirrors adjustable by stepper motors

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Partial conclusions

Partial Conclusions

  • Described model allows for monitoring and control of non-standard devices in ALICE – not only FERO

  • The FERO is treated as a device. The developed software makes all hardware details transparent to higher software layers

  • We need your feedback in order to be able to standardize the commands

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


A working fed server is just the beginning of the story

A working FED server is just the beginning of the story…

  • Implementation of FERO software is a very complicated task requiring a lot of expertise – however it is still the easier part

  • Tuning of the software will require much more time and experience

  • DCS team is happy to discuss and help at least to transfer the knowledge between different groups. (Maybe someone already solved a problem which you are dealing with…)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Configuration errors

Configuration Errors

Wrong Configuration Data

Non-working chip

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


What is the source of erroneous data

What is the source of erroneous data?

  • Wrong configuration record in database

  • Wrong configuration version retrieved from database

  • Data transmission errors

    • interference with DAQ, TRG, crosstalk, …

    • single event effects …

  • Software errors

    • Interference between monitoring and control

    • Interference between control tasks

  • Interference between several clients – PVSS should be the ONLY client allowed to send commands to FED Server

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Communication between online systems and sub systems

Communication between online systems and sub-systems

  • There are many cases when online systems need to be synchronized – in fact this is probably the most complicated FERO related problem

  • Procedures depend on hardware architecture as well as on detector operational modes

  • Spotting of problems and implementation of correct procedures requires close collaboration between different specialists

  • The first step is to understand the operation of the sub-detector and then analyze consequences for each case

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Just a few examples

… just a few examples

  • Some operations require additional actions:

    • Power sequence might temporary lead to a very high power consumption – software interlock levels must be raised until the situation stabilizes (e.g. until FERO initialization). In addition a RESET must be sent to FERO and some dummy configuration loaded, so an action on LV triggers an action on FERO as well.

  • Additional action from other systems might be necessary:

    • (Re-)Initialization might require stopping of trigger (downloading of data sometimes introduces unwanted noise, running DAQ sequence might corrupt currently downloaded data)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Just a few examples1

… just a few examples

  • Typical initialization sequence is not a single-step procedure and can be even split between several systems:

    • DCS must assure the power and cooling are present

    • DCS related circuitry will be loaded and checked

    • Only now the DAQ can proceed with configuration

    • Additional adjustments and checks performed by DCS might be needed

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Few more examples

… few more examples

  • DCS can detect and correct problems which are not immediately visible to other online systems.

  • Problems in DCS sub-system can affect other online system

  • In some cases DAQ and TRG will be asked to perform additional actions

    On following slide we use a generic “CLASS A” front-end to demonstrate the problem

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Typical problem requiring synchronization between online systems

Typical problem requiring synchronization between online systems

VR Failure

(e.g. due to SEU)

ECS

FERO lost its Configuration

DCS

TRG

DAQ

Recovery Action by DCS

DCS informs the DAQ

and TRG via ECS

VR

FERO

DAQ reloads the FERO

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Propagation of hardware related problems

Propagation of hardware related problems

  • Problems can propagate between sub-systems and affect different parts of the detector:

    • E.g. recovery of a VR failure could lead to corruption of configuration in neighboring sector (spikes, etc.).

  • Such problems can remain hidden (e.g. change in threshold settings) and will be discovered only by offline

  • If we are aware of potential problems we could maybe use a simple procedure to correct them before they badly affect the data

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Things to be understood

Things to be understood

  • In principle every single chip can be acessed individually. Allowing for such access would lead to complications for some architectures

    • Example: rather than creating a service for each individual temperature sensor we could create groups for sub-detector modules and publish all data together

    • This requires balancing between number of services and update rates (we should not update a service with 1000 values if only one value changes, but we also do not want to have 1000 individual services instead)

  • Partitioning of sub-detectors should be done very carefully (taking into account both control and monitoring aspects)

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


A few more things to be understood

A few more things to be understood

  • What should be the structure of DIM commands?

    • Command structure should include the target and data to be transferred.

    • Should we define standards for payload or set weak rules? The segmentation and naming differs between sub-detectors, definition of common standard would not be intuitive and therefore will lead to errors.

  • It is essential to create a naming convention for each detector and understand its segmentation in terms of control, DAQ readout and monitoring.

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Still some question marks

Still some question marks

  • What is the amount of data to be exchanged between DCS and FERO and at what frequencies?

  • What is the structure of this data

    • Example: temperatures for given sector can be sent as an array containing values for each probe. Another approach would be to send data structure containing only values which have changed and decode this information in PVSSII

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


Yet another one

…yet another one

  • What should be the granularity of agents?

    • Should we set common deadbands for all values acquired by the individual agent? (e.g. update temperature readings if any of them changes by more that 0.5C) – PVSSII will of course provide another level of filtering of these values

    • Should be the deadbands set more precise? (e.g. allowing for masking of faulty sensor at the level of FED server)

  • All answers depend on individual architectures.

Peter Chochula – ALICE DCS DCS Workshop – March 2004, Geneva


How to proceed

How to proceed?

  • Working and stable FED server is the starting point. It can be developed in advance – using emulators in the hardware access layer

  • Once the hardware arrives, one could fully concentrate on operational aspects. New procedures will be discoverred with time and can be implemented in software

  • Communication with other sub-detectors is essential. DCS team is happy to assist you in this point.