An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Updated Concerns on the Material Interactions Dai-Kai Sze University of California, San Diego Presented at the ARIES Project Meeting September 3-5, 2003 Atlanta, Georgia

  2. Material Interactions • The compatibility between the structural materials and coolant/breeding materials set key limitations on the allowable temperature. • The allowable corrosion rate is about 10 mg/m2-h. • The corrosion rate is strongly temperature dependent. • Relax of the corrosion rate will have only a small effect on the allowable temperature.

  3. Corrosion Concerns • Literature review identified they are limited information on the results of corrosion studies. • Some of the experimental results do not support the conventional window. • Much more experimental works will be required to define the corrosion rates. • Some results for the Li/V, LiPb/SiC and flibe/FS will be discussed here.

  4. Li/V compatibility • One of the key reasons to use the Li/V blanket is that Li is compatible with V-alloy to high temperature(600 to 700°C). • BCSS suggested that V is very compatible with Li. • Some existing data does not agree with this conclusion.

  5. Results from ANL work • Dissolution rates of V in Li were measured for different type of V-alloys. • This experiment was done in a forced convection loop with Li circulating rate of about 1 liter/m. • The corrosion behavior was evaluated by measuring weight change. • The N concentration was between 20 to 100 WPPM. • Chopra and Smith, “Corrosion behavior of Vanadium Alloys in Flowing Lithium,” Journal of Nuclear Materials, 155-157 (1988).

  6. Corrosion Rate of V-15Cr-5Ti • Reported corrosion rates: 482°C 427°C 4.97 mg/m2-hr 0.27 mg/m2-hr • The corrosion rate will be 0.1 cm/y at 600C, and 0.5 cm/y at 650C, by extrapolating from the low temperatures. ).

  7. Other Results • Corrosion of V3Ti1Si by Li was measured by Adelhelm. • A pumped Li loop was used, with velocity of 7 cm/s. • The Li temperature was 806 to 823K. • The N concentration was 8 to 64 wppm. • The measured V corrosion rate was between 2 to 20 mg/m2-hr. • There was a minimum corrosion rate at XN = 30 ppm. Gh. Adelhelm, “Corrosion of V3Ti-1Si in flowing Lithium,” Fusion Technology,8, July 1985, P. 541.

  8. Other Information • Some work from RF reported weight gain in V/Li corrosion experiments. • Those were from capsule tests with very high N concentration. • No data is available to suggest that the corrosion rate on V by Li is low at high temperature. • Chopra concluded “the dissolution rates of all vanadium alloys were greater than of ferritic steels (in his experiments).”

  9. Question • What is the base to suggest that Li/V blanket can operate at 600 to 700°C?

  10. LiPb/SiC Compatibility • It has been suggested that LiPb and SiC is compatible up to 800°C, and maybe higher. • Available experimental results do not support this suggestion. • Based on experimental results, it can not be concluded that if SiC is compatible, or not compatible, with LiPb at 800°C.

  11. LiPb/SiC Experiment • The work was done in a rotating disk set up, with a rotational speed of 800 revolutions/m (1.67 m/s). • The temperature of the experiment was 800°C, and up to 3100h. • Both the coupons and the LiPb sample were investigated at the end of the experiements.

  12. SiC Coupons • It was difficult to clean up LiPb from the SiC coupons. • Therefore, it was not possible to measure the weight variation of the SiC speciman after the test. • No information was obtained on either weight gain, or weight lost, during its contact with liquid LiPb.

  13. LiPb Samples • The Si concentration in LiPb is about 12 wppm, both before and after the test. • The author suggested that no dissolution occurred during the test perhaps due to the low Si solubility in LiPb. • However, this also suggested that the Si is saturated in LiPb at a concentration of 12 wppm. • 12 wppm is a very high solubility. If we assume that the Si concentration in LiPb is always at a saturation level, (Which may not be), the removal rate of Si from SiC will be very high. • There is potential that the entire blanket structure can be removed in one day. • 12 wppm solubility is a cause for concern.

  14. LiPb/SiC Compatibility • There is no data available to suggest if SiC is compatible to LiPb at 800°C, or not compatible. • ORNL recently did some SiC/LiPb compatibility test, at 1000°C and 800°C. • Air in leak ruined the 1000°C experiment. • ORNL is still investigating methods to remove LiPb from the SiC coupons.

  15. REDOX Reaction • For MSBR, the following Redox reaction was used to control TF and F2 potential. UF3 + F ----- UF4 • A possible Redox reaction for fusion application is   Be + 2F ---- BeF2 • This redox reaction is being studied at INEL as a part of JUPITER-II collaboration.

  16. Conclusion • There are only limited experimental results to assess the compatibility between many structural materials and coolant/breeding materials. • Careful review of those results raised questions on the temperature limits set for the systems. • More detailed assessments on the condition of the experiments, the results of the experiments, and the conclusions draw from those results is required.