comparison o f kinematic results between metu kiss ankara university vicon gait analysis systems
Download
Skip this Video
Download Presentation
Comparison o f Kinematic Results Between METU-KISS & Ankara University-VICON Gait Analysis Systems

Loading in 2 Seconds...

play fullscreen
1 / 17

Comparison of Kinematic Results Between METU-KISS Ankara University-VICON Gait Analysis Systems - PowerPoint PPT Presentation


  • 170 Views
  • Uploaded on

Comparison o f Kinematic Results Between METU-KISS & Ankara University-VICON Gait Analysis Systems. EZGİ CİVEK supervised by: Asst. Prof. Dr. Ergin Tönük Prof. Dr. Turgut Tümer. Outline. Introduction Gait Analysis Motion Capture Systems Comparison of the two systems

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Comparison of Kinematic Results Between METU-KISS Ankara University-VICON Gait Analysis Systems' - octavio


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
comparison o f kinematic results between metu kiss ankara university vicon gait analysis systems
Comparison of Kinematic Results Between METU-KISS & Ankara University-VICON Gait Analysis Systems

EZGİ CİVEK

supervised by: Asst. Prof. Dr. Ergin Tönük

Prof. Dr. Turgut Tümer

outline
Outline
  • Introduction
  • Gait Analysis
  • Motion Capture Systems
  • Comparison of the two systems
  • Comparison of the kinematic results
  • Future Studies
objective
Objective

To compare the kinematic results of two different gait analysis systems.

Data Acquisition Data Analysis

Performance Methodology

  • Exchanging the motion data between KISS & VICON.
  • Studying the same subject on each system.
objective4
Objective

To make KISS compatible with a common widely used file format.

To enlarge the database available.

gait analysis
Gait Analysis

Analysis of the mechanics of human body during walking, stair ascending/descending, obstacle avoidance.

gait analysis6
Gait Analysis

Gait analysis plays a key role in:

  • Diagnosis of disorders in lower extremity
  • Decision making before operations
  • Evaluation of prosthetic joint replacements
  • Comparison of gait parameters before and after operations
  • Studies in orthotics, amputees, athletic injuries
motion capture systems
Motion Capture Systems

SOFTWARE

  • Data Acquisition
  • Calculation of Gait Parameters

HARDWARE

  • CCD Cameras
  • Markers
  • Force Plate(s)
  • EMG Unit
kiss vicon
KISS VICON

Commercial system

5 cameras

2 force plates

VICON 370

Vicon Clinical Manager

Helen Hayes Marker set

Locally developed in ME

6 cameras

2 force plates

KISS – DAQ

KISS – GAIT

Helen Hayes Marker set

slide11

File Formats

input for kinematic data analysis

c3d a 3d biomechanics data standard
C3D - A 3D Biomechanics Data Standard
  • Developed by Andrew Dainis in 1987.
  • Used by almost all commercial motion capture systems.
converting yor file to c3d
Converting *.yor file to *.c3d
  • Export the coordinate data from *.yor file as *.txt format.
  • Arrange the data in text file according to c3d format.
  • Create *.c3d file by a program called ‘C3D Editor’.
slide15

VICON

KISS

future studies
Future Studies
  • Converting *.c3d to *.yor file format.
  • Studying the same subject in both systems.
  • Writing a program for the arrangenments of files required in the conversion process.
ad