SR Heating calculation

Mar. 18, '09. SR Heating calculation. KEK H. Yamaoka T. Kohriki. Contents - Introduction - Calculations Configuration-A Configuration-B - Conclusion. Be:t0.35mm. Gap 0.5mm. Au: t5mm. Be:t0.5mm Au: t0.01mm. O.D. 32.7. I.D. 29.9. I.D. 32.0. O.D. 31.0. Introduction.

Download Presentation

SR Heating calculation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mar. 18, '09 SR Heating calculation KEK H. Yamaoka T. Kohriki Contents - Introduction - Calculations Configuration-A Configuration-B - Conclusion

  2. Be:t0.35mm Gap 0.5mm Au: t5mm Be:t0.5mm Au: t0.01mm O.D. 32.7 I.D. 29.9 I.D. 32.0 O.D. 31.0 Introduction Temperature on the B.P. due to an influence of SR has been calculated. Configuration-A (Single Be-pipe) Configuration-B (Double Be-pipe tube)

  3. Distribution of heat load 50W 18W 35W j=±p 40W 17W 18W 35W j=0 25W 60W 50W 35W

  4. Configuration of B.P. (@Single Be-pipe) 2. 1. 3. 4.

  5. Other assumptions Outer surface of the B.P. is cooled by liquid. Heat convection - Outer surface of the B.P. 3000W/m2・℃, 25℃ Boundaries are ideally connected. - Inside of the B.P.  0W/m2・℃ 48 58 300 Au Be Thermal conductivity (W/m・℃): 319 216 Specific heat (J/kg・℃): 128 1925

  6. Results (@Single Be-pipe) If no cooling were done…, Outer surface of the B.P.  3000W/m2・℃, 25℃ Max. 700degC Max. 80℃ Max. temp. vs. Cooling ability.

  7. Calculation-B (Double Be-tube) Be:t0.35mm Au: t5mm Be:t0.5mm Au: t0.01mm Gap 0.5mm I.D. 29.9 O.D. 32.7 I.D. 32.0 O.D. 31.0 2. In the Be-gap. 3000W/m2・℃、25℃ 1. Outer surface of the Au-Beam Pipe. 3000W/m2・℃、25℃ 3. Outer surface of Be-gap. 5W/m2・℃、25℃ 1. Outer surface of the Au-Beam Pipe. 3000W/m2・℃、25℃ 4. Inside of the B.P.  0W/m2・℃ Assumption: Cooling position  (Be-Gap + Outer surface of the Au-pipe)

  8. Results (Double Be-tube) Heat convection - Outer surface of the Au-B.P. 3000W/m2・℃、25℃ - Inside of Be-gap. 3000W/m2・℃、25℃ - Inside of the B.P.  0W/m2・℃ Max. temp. vs. Cooling ability. Max. 87℃

  9. Be:t0.35mm Gap 0.5mm Au: t5mm Be:t0.5mm Au: t0.01mm O.D. 32.7 I.D. 29.9 I.D. 32.0 O.D. 31.0 Conclusion Temperature rise on the B.P. has been calculated with two kinds of configurations. @Configuration-B (Double Be-pipe) Max. temp. vs. Cooling ability. (Double Be-pipe) In case of 3000W/m2C, 25degC; - The maximum temperature is appeared on the SR mask.  87degC - Temperature at other SR hit positions are around 30-35degC.  5-10degC of temperature rise.