KALIBRACIJA SONDE ZA PRITISAK VE Ž BA 2.1. Ana Ćulafić 124 / 04. SADR Ž AJ. UVOD EKSPERIMENTALNA INSTALACIJA POSTUPAK MERENJA OBRADA REZULTATA ZAKLJU Č AK. UVOD.

Download Presentation

KALIBRACIJA SONDE ZA PRITISAK VE Ž BA 2.1

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Kalibracija sonde za pritisak ve ba 2 1

KALIBRACIJA SONDE ZA PRITISAKVEŽBA 2.1

Ana Ćulafić 124/04


Sadr aj

SADRŽAJ

  • UVOD

  • EKSPERIMENTALNA INSTALACIJA

  • POSTUPAK MERENJA

  • OBRADA REZULTATA

  • ZAKLJUČAK


Kalibracija sonde za pritisak ve ba 2 1

UVOD

  • CILJ VEŽBE JE KALIBRISANJE DRUCK SONDEZA PRITISAK POMOĆU EKSPERIMENTALNE INSTALACIJE, ČIME SE DOBIJA KALIBRACIONA KRIVA.

  • KALIBRACIJA JE PROCES KOREKCIJE MERNOG INSTRUMENTA RADI POSTIZANJA ŠTO VEĆE TAČNOSTI, NJOME SE SMANJUJU SISTEMATSKE GREŠKE.

  • KALIBRACIONA KRIVA JE REZULTAT KALIBRACIJE


Kalibracija sonde za pritisak ve ba 2 1

EKSPERIMENTALNA INSTALACIJA


Kalibracija sonde za pritisak ve ba 2 1

POJAČIVAČ I VOLTMETAR

EKSPERIMENTALNA INSTALACIJA


Postupak merenja

POSTUPAK MERENJA

  • ISPUSTITI VAZDUH IZ SONDE

  • PRIKLJUČITI KONEKTOR, POJAČIVAČ I VOLTMETAR

  • PODESITI NULU SONDE

  • PODESITI POJAČANJE ZA MAKSIMALNI OPSEG PRITISKA

  • OČITATI U VIŠE PROMENA VISINU VODENOG STUBA I NAPON NA VOLTMETRU


Kalibracija sonde za pritisak ve ba 2 1

EKSPERIMENTALNA INSTALACIJA


Obrada rezult a ta vr i se u excel u

OBRADA REZULTATA VRŠI SE U EXCEL-U


Kalibracija sonde za pritisak ve ba 2 1

H=A*U+B

P=C*U+D


Kalibracija sonde za pritisak ve ba 2 1

H=A*U+B

P=C*U+D


Zaklju ak

ZAKLJUČAK

  • KALIBRISANJE INSTRUMENTA JE NEOPHODNO RADI DOBIJANJA ŠTO TAČNIJIH I POUZDANIJIH REZULTATA , IAKO ČESTO PREDSTAVLJA NAPORAN I DUGOTRAJAN PROCES.


Hvala na pa nji

HVALA NA PAŽNJI!!!!