1 / 9

VH Series How to Compete Against…

VH Series How to Compete Against…. Design. Dimensions (HxWxD). Manufacturer Model Power Layout. Display. Comm.Port. 700 VA to 3 kVA. USB EPO standard. Rotatable Control Panel with LED. 440x87x472 440x87x547. Tower/Rack convertible. VH.

nishan
Download Presentation

VH Series How to Compete Against…

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VH Series How to Compete Against…

  2. Design Dimensions (HxWxD) Manufacturer Model Power Layout Display Comm.Port 700 VA to 3 kVA USB EPO standard Rotatable Control Panel with LED 440x87x472 440x87x547 Tower/Rack convertible VH 242x153x440/490 Tower 86.5x438x483 Rack USB EPO standard 700VA to 3kVA Tower or T/R convertible (2U or 3U) LED +Multilingual display Pulsar 410x155x240 445x170x275 470x215x365 580x280x570 700 VA to 6 kVA USB EPO n.a. LED +Display Tower 9120 2 kVA 3kVA (same dim.) 432x85x483 Tower 86.5x438x483 Rack RS 232 EPO as option Tower/Rack 2 different layouts Control Panel with LED Smart UPS RT 700 VA to 3 kVA 231x158x400 231x158x500 340x192x460 RS 232 EPO n.a. Control Panel with LED Tower Dialog Plus

  3. Input Performance Voltage range Frequency range Manufacturer Model THDi Power Factor 160-280V (full load) 40-70 Hz <6% 1 VH 190-284V load P.F. 0.9 160-284V load P.F.< 0.7 1 (measured at full load) 6.10% (measured) 40-70 Hz Pulsar 120-250V (measured)vs. >0.97 (0.7-3kVA) 7.20% (measured) 47-63 Hz 120-276V (declared) 9120 8.5% (measured) 0.99 (measured) 100-280V 45-65 Hz Smart UPS RT 160-300V (full load) Sinusoidal (<8%) >0.97 45-65 Hz Dialog Plus

  4. Output Performance Overload Capability Non linear load capability Voltage regulation THDU Manufacturer Model Power Factor 1* 110% 5mins 150% 2sec. +/- 2% Up to 6:1 crest factor <2% VH 0.9** n.d. n.d. n.d. n.d. Pulsar Up to 125% 1min. 125-150% 10sec. +/- 2% online +/-3% on battery n.d. n.d. 0.7 9120 3:1 crest factor n.d. <3% 0.7 n.d. Smart UPS RT 110%30mins. 130% 30sec. 150% 10 sec. Up to 3:1 crest factor 0.7 +/- 1.5% <2% Dialog Plus *at standard (70%) load **with input voltage restriction

  5. Environmental Working Temperature Manufacturer Model Efficiency Audible Noise Altitude Up to 91% full load Up to 89% 50%load <3000m <45dB(A)* -10 +40°C** VH n.d. 45dB(A) 0-40°C n.d. Pulsar >88% full load 85.6% half load (measured) <45dB(A) (0.7-1.5kVA) <50dB(A) (2- 3kVA) 0-40°C <3000m 9120 50dB(A) Up to 90% full load 0-40°C <3000m Smart UPS RT Up to 90% <40dB(A) 0-40°C n.d. Dialog Plus * With load and temperature dependent fan speed – not offered by competitors **Unique temperature compensation on charging limits battery damage; competitor UPS have no/limited compensation, operating outside 20-25°C will shorten battery life

  6. Options DC Connectors for longer autonomy External Bypass Backfeed Protection RPA Manufacturer Model Available on all models except 700VA optional No As standard* VH Available on all models EXB connectors 2units with Modular Kit* (2.2-3 kVA) optional n.d. Pulsar Available on all models optional n.d. No 9120 Available on all models n.d. n.d. No Smart UPS RT Available on all models except 700VA No n.d. No Dialog Plus * Backfeed protection is mandatory for this type of UPS (IEC 62040), no additional costs for VH Series **Additional dedicated PDU required, expensive option (~30%of the total price)

  7. Other Permanent frequency converter Typical warranty Bypass type High peak load handling Manufacturer Model Static switch* 3 years UPS 3 years battery Yes Yes VH 2 years UPS 2 years battery Relay No No Pulsar 2 years UPS 12 months battery Relay No No 9120 2 years UPS 12 months battery No No Relay Smart UPS RT 2 years UPS 12 months battery Relay No No Dialog Plus *Static switch has higher reliability and faster transition than relays

  8. Unique VH Series Benefits Same cabinet for tower/rack applications, associated parts shipped with unit Best input performance (THDi), Power Factor and Frequency Range High peak load handling protects batteries when supporting printers and other step loads Highest suitability for non-linear load (6:1 crest factor) High efficiency (to 91%) Controlled fan speed, load dependent air ventilation Bypass transfer time reduced by TRIAC technology (versus slower and less reliable relays offered by competitors) Direct battery charging from mains; VH Series can start up even with deeply discharged batteries 3 year warranty on UPS and battery All data indicated in datasheet is truly measured and accurately communicated