Gateway Training Workshop Module Two. Advanced Gateway Operations Audio Control Units (ACU). Patrick Kempker Gateway Instructor OEC/ICTAP [email protected] (619) 553-5172. Glossary.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Gateway Training Workshop Module Two' - nina-york


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Gateway training workshop module two

Gateway Training Workshop Module Two

Advanced Gateway Operations

Audio Control Units (ACU)

Patrick Kempker

Gateway Instructor

OEC/ICTAP

[email protected](619) 553-5172


Glossary
Glossary

COR/COS Carrier Operated Relay/ Carrier Operated Squelch - A receiver signal that gives a positive indication a carrier or signal is being received and the receiver is unsquelched.CPM-2/4/6 Control Processor Module - This ACU module controls all aspects of system operation.

DTMF Dual Tone Multi Frequency - The standard touch-tone telephone dialing method sends DTMF characters over the Public Switch Telephone Network (PSTN) line.

DSP Digital Signal Processing (or Processor).

DSP-1/2/2IP The Digital Signal Processor Module, the main radio interface of the ACU-1000 system. DSP algorithms provide Voice Operated Transmit (VOX), Voice Modulation Recognition (VMR), Audio Delay, Noise Reduction, and Tone Keying functions.

Extension Each interface module in the ACU-1000 system is given an extension number. A user enters this extension number to make a communications link through the selected module.


Glossary cont
Glossary Cont.

HSP-2/4/2IP The ACU-1000 Handset/Speaker/Prompt Module provides a local operator interface and the system voice prompt circuitry.

INMARSAT International Marine/Maritime Satellite

PSTN-1/1IP Public Service Telephone Network module to interface to the Public Switch Telephone Network

PTT Push to Talk

RX Receive or Receiver

SIP Session Initiation Protocol

SCM-1/2 SIP Channel Module

Squelch A means of detecting audio and causing some action when it is present, such as keying a transmitter or unmuting an audio path.

TX Transmit or Transmitter.

VMR Voice Modulation Recognition. A type of squelch, which is activated only by spoken words and not by tones, noise, or other audio information.

VOX Voice Operated Xmit (Transmit). A circuit or algorithm, which causes a transmitter to key or some other action when voice is present. This squelch type is activated by any audio signal, and is not restricted to voice only.


Advanced gateway operations overview

Requirement & Capabilities

Setup & Configuration

Creating & Breaking Patches

Advanced Gateway Operations Overview


Requirements capabilities acu family raytheon jps

TRP-1000

ACU-1000

Requirements & CapabilitiesACU Family – Raytheon JPS

  • Four (4) to twenty-four (24) interconnected communications devices (only 16 active at one time)

  • Patch Up to seven (7) new networks

  • Five (5) Patch Types

    • Normal, Vertical, Priority, Monitor, Permanent

  • Individual Module/Port Adjustments

  • Password Protection

    • (PINs, Permanent Connections, and Module Settings)

ACU-M

ACU-2000IP

ACU-T


Requirements capabilities acu family
Requirements & CapabilitiesACU Family

  • Power

    • AC 110 – 220 V

    • DC power

  • Computer Controllable

    • Free ACU Controller Software

      • R/S-232 connection

      • Network RJ-45 interface

    • Optional WAIS software for multiple ACU Control

  • VOIP – Free PCNXU software


Requirements capabilities control console software
Requirements & Capabilities Control Console Software

  • User-friendly graphical interface that is mouse-driven

  • Allows operators to

    • Quickly make and break inter-connections

    • Modify setup

    • Save and load configurations


Requirements capabilities control console software1
Requirements & Capabilities Control Console Software

  • Computer Requirements for Version 5.42

    • OS Windows 95, 98 Me, NT, 2000, XP, or Vista

    • The ACU Controller’s native screen resolution is 1280x1024, where it looks best and runs fastest; however, it will automatically adapt to fit any screen resolution.

    • 64MB RAM minimum

    • 50 MB free hard drive space

    • Serial port dedicated to communicate w/ACU or Ethernet Card (if using Ethernet control for ACU)

    • Mouse is recommended but not required

      Note: Proper operation of the ACU Controller with a CPM-2 module requires that the CPM-2 module has firmware revision 1.16 or higher.


Setup configuration control console generic screen
Setup & Configuration Control Console Generic Screen

Title

Pull Down Menu

Installed Modules

(Generic Display)

Column Heading

Shows which ACU slots contain modules

Connection

Indicator

Module Grid

Shows which modules belong to which nets

Net Area

Message Area


Setup configuration control console generic screen1
Setup & Configuration Control Console Generic Screen

Pull down menu


Setup configuration pull down menus
Setup & Configuration Pull Down Menus

  • There are six pull down menus

    • Sites

    • ACU

    • Tools

    • Interface

    • PermConn

    • Help

  • Each grouped into specific types of operation


Setup configuration sites menu
Setup & Configuration Sites Menu

  • Select Network Site – Allows users to control the ACU through an Ethernet port.

    Note: You require both IP address and port number for the ACU you want to control

  • Select Serial Port – Used when controlling the ACU through the RS-232 connector P13. CPM-2 connects using a 9600 baud rate, CPM-4 uses 115200 baud rate.

  • Note: The middle of the menu is a connection history

  • Auto Connect On Startup – When on the ACU controller attempts to restore its last successful connection on startup

  • Exit - Exits the controller software


Setup configuration acu menu
Setup & Configuration ACU Menu

  • Save Configuration - lets users store the present configuration

  • Load Configuration – Sets the ACU to a previously saved configuration

  • Retrieve Current Configuration – interrogates the ACU regarding it’s current configuration

  • Restore Last Configuration – reverts the ACU Controller to the state it was in last time it was powered down.

  • COR Reporting Displays the current COR status of each module

  • PTT Reporting – Displays the current PTT status of each module

  • Voice Prompts – Controls the ACU voice prompting to external users gaining access via DTMF


Setup configuration tools menu
Setup & Configuration Tools Menu

  • Password Protection – Sets which (if any) attributes require password: ACU PIN settings DB, Permanent Connections, Module Settings

  • ACU Security Settings – provides access to DB that sets PIN #s, User IDs & security levels

  • Module Web Pages – Stores IP addresses for the various VoIP modules

  • View Recent Log – Views the last 30 entries

  • View Entire Log – Open the whole log

  • New Log – Starts a new log


Setup configuration tools menu continued
Setup & Configuration Tools Menu (Continued)

  • Connect All – Connects all modules except unconnected PSTN-1 modules

  • Revert – Returns the modules to there original position before the connect all

  • Disconnect All – dissolves all current interconnections (nets)

  • Revert – All modules (other than PSTN-1 modules) are returned to whatever nets they were in prior to the Disconnect all


Setup configuration interface menu
Setup & Configuration Interface Menu

  • Sound – Turns sound on or off

  • Allow ACU M-Style Interface – When checked, the ACU Controller will use its special ACU-M interface when connected to an ACU-M

  • Show Hover Icon Description – full module descriptions that appear near the mouse cursor when the cursor hovers over a module icon

  • Right Mouse Button – set either to disconnect the module, or to view the module settings

  • Connection Indicator - Select between disconnect or enter module’s setting screen

  • Animation – Sets the Icon movement speed when a patch is made or broken

  • Window Title – Sets the title on the Main ACU Controller screen

  • Change Colors – Change background and grid colors



Setup configuration permconn menu
Setup & Configuration PermConn Menu

  • One of the five types of patches covered later in the practical demonstration

  • Acts as a toggle (On/Off)

  • After a patch or patches are made forming new nets, any of the nets (1 through 7) selected via this pull-down menu will become a Permanent Connection


Setup configuration help menu
Setup & Configuration Help Menu

  • About – Gives you the information about your ACU Controller software Name and version number

  • Manual – Gives you access to the “ACU-Controller Control Software for the ACU-1000 and the ACU-T Software Installation and Operation Manual”


Setup configuration personalized screen
Setup & Configuration Personalized Screen

Personalized Icons


Creating breaking patches keyboard operations
Creating & Breaking Patches Keyboard Operations

  • Making and breaking connections with the keyboard consists of the same operations that would be used with the mouse, except each mouse click has a corresponding keystroke series: The “##” symbol represents a two-digit module and the # represents the one-digit net number in each command.

    • Click on module icon (left-click or Connect): c##

    • Right-click (Disconnect) on module icon: d##

    • Click on net number icon (Vertical Connection): n#

    • Right-click on net number icon (Break VC.): b#

    • Click on column heading (enter/exit Monitor Mode): m##

    • Toggle Connect/Disconnect Mode Modules to Mon: t

  • These commands are case-sensitive; all must be lower-case


Creating breaking patches connection types
Creating & Breaking Patches Connection Types

  • Five types of connections

    • Normal - form new nets

    • Vertical - join existing nets together

    • Priority - temporarily patch members of existing nets together, removing them from their original nets for the time being

    • Permanent – add protection to existing nets

    • Monitor – one-way connection – listen, but not speak


Creating breaking patches normal connections
Creating & Breaking Patches Normal Connections

  • Each connection takes two left clicks of the mouse to make or one right click to break

    • Create a net – left click on one idle module then left click on another one, to create additional nets - repeat step

    • To add more than two modules to net left click on the desired idle module then left click on the net number or one of the module already on the net

    • To break a module from a net right click the module to break an entire net right click the net number


Creating breaking patches vertical connections
Creating & Breaking Patches Vertical Connections

  • Connect two or more nets together – These are temporary connections intended to allow communications between nets for a short time

    • To join – left click on a net number and then left click on the net number you want to join it

    • To disconnect - right click on a net number you want to remove


Creating breaking patches priority connection
Creating & Breaking Patches Priority Connection

NOTE: This is to temporarily patch active members of existing nets together, temporarily removing them from their original nets

  • To join – left click on one active module in a net then left click on the desired module in a different net

  • To disconnect - right click on the red number in the module icon


Creating breaking patches permanent connection
Creating & Breaking Patches Permanent Connection

  • Adds protection to nets so you can not accidentally disconnect the modules in them - Permanent Connection.

    • To create – Make normal net as shown on the normal connection slide. Next on the dropdown tool bar select PermConn. Select the net number you want to make permanent. The letters “PC” appear in the connected modules.

    • To remove – PermConn is a toggle switch. On the dropdown tool bar select PermConn then select the net number you no longer want protected the letters “PC” disappear. The net can now be deleted in the normal fashion.


Creating breaking patches monitor mode
Creating & Breaking Patches Monitor Mode

  • Monitor works differently than all the other connections

    • To start monitoring - Enter monitor mode by left clicking on the column heading of module you want to do the monitoring, the screen changes

    • Left click on the modules you wish to monitor

    • Left click on the column heading again to return to the normal screen


Creating breaking patches monitor connection
Creating & Breaking Patches Monitor Connection

  • The M in the module’s icon shows who is doing the monitoring and the numbers below shows which modules are being monitored

  • To remove monitor - enter monitor mode by left clicking on the column heading

  • Left click on the modules you no longer wish to monitor

  • Left click on the column heading again to return to the normal screen

    Note: The M disappears from the module’s ICON


Questions
Questions

????


OEC/ICTAPOffice of Emergency Communications / Interoperable Communications Technical Assistance Program