1 / 17

Recent progress on MIMOSA sensors

Recent progress on MIMOSA sensors. A.Besson, on behalf of. IReS/LEPSI : M. Deveaux, A. Gay, G. Gaycken, Y. Gornushkin, D. Grandjean, F. Guilloux, S. Heini, A. Himmi, Ch. Hu, K.Jaaskelainen, M. Pellicioli, H. Souffi-Kebbati, I. Valin, M. Winter,

nika
Download Presentation

Recent progress on MIMOSA sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent progress on MIMOSA sensors A.Besson, on behalf of IReS/LEPSI : M. Deveaux, A. Gay, G. Gaycken, Y. Gornushkin, D. Grandjean, F. Guilloux, S. Heini, A. Himmi, Ch. Hu, K.Jaaskelainen, M. Pellicioli, H. Souffi-Kebbati, I. Valin, M. Winter, G. Claus, C. Colledani, G. Deptuch, W. Dulinski, M. Szelezliak (M6/M8 DAPNIA: Y. Degerli, E. Delagnes, N. Fourches, P. Lutz, F.Orsini) • Fabrication technology • Parameter optimization (pitch, T, diodes, etc.) • Signal treatment and read-out speed • Thinning • Radiation tolerance

  2. MIMOSA 9 (1) • Main features: • Techno opto. • Self Bias / Standard • Pitch 20/30/40 m • Small/large diodes (3/6 m) • With/without epi. 0.96 mm 1.2 mm 3T, 40 m 32 x 32 SB, 30 m 32 x 32 5 x 5 m Explore the different parameters SB, 20 m 64 x 64 SB, 40 m 32 x 32 A.Besson

  3. MIMOSA 9 (2) • Beam test @ CERN-SPS (120 GeV/c -) Charge (1 pixel); MPV ~ 325 (25 pixels); MPV ~870 (9 pixels); MPV ~ 850 MPV ~ 24 Self-Bias, Pitch = 20 m, diode 6 x 6 m2 A.Besson

  4. MIMOSA 9 (3) • First comparisons: • SB with 20/30 m pitch : eff ≥ 99.8% • Resolution ~ 1.5 m @ 20 m pitch • Analysis in progress: • Temperature • Chip without epi. • Hit selection optimization Sp. Resolution; SB, diode 3.4 x 4.3 m2 Noise (e-) vs Diode surface m2 A.Besson

  5. Fast read-out architecture • Different developments based on Mimosa 6 • VX DET layer 1-2: • Fast, column // readout, with hit selection • VX DET layer 3-4-5: • Multiple scans of the whole detector within train (r.o. ~200 s). • Then read the samples between trains • Integrate capacitors in each pixel (M7 and M8) • Mimosa 7 • Features • photoFET. • 25 m pitch, No epi., 0.35 m, 64x16 readout in // with CDS • Status • Being tested • Beam test in Oct. • Mimosa 8 (with DAPNIA) • Features • 25 m pitch, 8 m epi., 0.25 m, 128x32 readout in // with CDS • Signal discrimination • Status • Being tested A.Besson

  6. Thinning • Mimosa 5 thinned down to epi. layer • Beam test. @ CERN • S/N M5-B thinned down M5-B standard A.Besson

  7. MIMOSTAR • STAR exp. upgrade: 1st proto sent for fabrication • Extension of the Vertex Detector (2 layers) • Running conditions • T amb. (higher leakage current). Readout time ~ 4ms • Features • Opto technology to reduce noise • TSMC 0.25 techno • Based on M5 • Pitch = 30x30 m2. 128x128 pixels • Surface: ~ 4 x 5 mm2 • Subdivision in 10 groups of columns • Pure analogic output. 10x10MHz output • Status • Expected back from fab. end Oct. A.Besson

  8. Radiation hardness • SUC 1: • Chip with 8  pixels design. 30 m pitch • Goal: study charge loss after irraditaion (X-ray) • Irradiation: • X-ray: 500kRad and 1MRad • Calibration with 55Fe • Measure leakage current @ different T • Being analysed • Charge loss  for some pixel designs • Leakage current • Next irradiation + beam test • M9 (X, n) • M5 (n)  Seems to stand 1 MRad A.Besson

  9. Conclusion and outlook • Geometry • Efficiency and resolution ok from 20 to 40 m • New techno opto. AMS 0.35 m • Epi. Layer may change • Chip read-out architecture • 2 research lines • layer 1-2 : r.o. speed • Layer 3-4-5 : storage capacitors • 2 proto being tested • Promising results • Radiation hardness • Studies in progress • Evidence  stand > 0.5 MRad. Up to 1MRad. • M9 (n,X), M5 (n) A.Besson

  10. Mimosa prototypes A.Besson

  11. A.Besson

  12. A.Besson

  13. A.Besson

  14. A.Besson

  15. Mimosa 9 (preliminary) A.Besson

  16. Beam tests: résumé. • 3 sessions (mai, juillet, aout). • Chips testés: • M5B: 202, 205, 306. • M5 15 m: “nGD” • M9: 1,2 (avec epi.) et 7(sans epi.) • 150k evts/run. 3/4 pts de Temp. • Remarques • Inversion du trigger pour M5 15 m • Veto apres le reset pour M9. 2  10 frames. • ~ 50% d’efficacité… • A faire: • Calibration M5 nGD. • M9 sans epi. • M5 et M9 irradiés • M7 A.Besson

  17. A.Besson

More Related