3211 Sat 10 th November 2012. Summary. BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards. Swapping of H/V cables on INJ-BPM-01 few times within short time invervals . INJ-BPM-01 signals vs SOL-01 Record AR1 BPM signals to study frequency contents.

Download Presentation

3211 Sat 10 th November 2012

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


3211 sat 10 th november 2012

3211 Sat 10th November 2012


Summary

Summary

  • BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards.

  • Swapping of H/V cables on INJ-BPM-01 few times within short time invervals.

  • INJ-BPM-01 signals vs SOL-01

  • Record AR1 BPM signals to study frequency contents.

  • INJ-BPM-03 signals simultaneously with INJ-FCUP and PI laser power trace.

  • Key finding: The 6 MHz seen in October ‘12 data is not present now.


Bpm normalisation error studies on inj bpm 01 using different rack room cards

BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards.

With the ‘normal’ rack room card (08) this is an example of what the x,y, charge signals look like

Note:-

Droop on x and charge

spikes on y


Bpm normalisation error studies on inj bpm 01 using different rack room cards1

BPM normalisation error studies on INJ-BPM-01 : using different (rack room) cards

  • Take fourier of the bunch train signals with initial transient (6.25 μs) and final droop (25 μs) removed => 70 μs section of the train

whole spectrum including aliasing, no 6 MHz evident

minimum frequency resolvable for 70 μs train is 1/70 μs = 15 kHz


Bpm normalisation error studies on inj bpm 01 card 06

BPM normalisation error studies on INJ-BPM-01 : CARD 06


Bpm normalisation error studies on inj bpm 01 card 04

BPM normalisation error studies on INJ-BPM-01 : CARD 04


Bpm normalisation error studies on inj bpm 01 card 08

BPM normalisation error studies on INJ-BPM-01 : CARD 08

NB mistake here


Conclusions on inj bpm 01 vs bpm attentuation

Conclusions on INJ-BPM-01 vs. BPM attentuation

  • The 300 kHz amplitude in the sum_voltage signal seems to depend on the BPM attenuation. Higher attenuation, lower amplitude.

  • Behaviour of other low frequency components not very clear.


Swap cables x y charge

Swap Cables – X, Y, CHARGE

attenuation = 15

attenuation = 18

reference

  • Switch cables for H pickups to V pickups; and vice versa.

swap cables

swap cables back


Swap cables fourier transforms

Swap Cables – fourier transforms

attenuation = 15

attenuation = 18

reference

swap cables

swap cables back