An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What Templates Can Do For You

  2. Before Templates • Except for PCCU Configuration Menus, Totalflow worked exclusively with fixed data structures (pre-defined groupings of individual variables) • Poll Records / Status Records • Configuration Records • Characteristic Files • Event Files • Flow Files • Log Period Records • Daily Records

  3. With Templates • Totalflow also supports working with individual data elements (registers) • Poll variables / Status variables • Configuration variables • Custom application data • Some support for historical data

  4. With Template Based Access • You Get • More flexibility • Not locked into pre-defined groupings of data • Faster Customization Capability • Less Costly Customizations • You Lose • Efficiency of structure based access • Protection of Audit TrailAudit records (data structures) should be transferred in the same overall transaction to protect against later ambiguity. So… we still collect audit data as structures.

  5. Example of Poll (Get Status) Report from RTU before Templates EIO-6610 AAI HARTMANN & BRAUN USA 09/22/93 00:01:18 AI CHAN. 1 -0.0001 VOLTS X - DIG. IN 1 inact. - AI CHAN. 2 -0.0001 VOLTS X - DIG. IN 2 inact. - AI CHAN. 3 0.1133 VOLTS - X DIG. IN 3 inact. - AI CHAN. 4 0.1127 VOLTS - X DIG. IN 4 inact. - AI CHAN. 5 0.1249 VOLTS - X DIG. IN 5 inact. - AI CHAN. 6 0.0935 VOLTS - X DIG. IN 6 inact. - AI CHAN. 7 0.1249 VOLTS - X DIG. IN 7 inact. - PI CHAN. 1 0.0000 COUNTS - - DIG. IN 8 inact. - PI CHAN. 2 0.0000 COUNTS - - DIG. OUT 1 inact. - Flow Rate 0.0000 MCF /DAY X - DIG. OUT 2 inact. - AO CHAN. 2 0.0000 PERCENT X - DIG. OUT 3 inact. - Abs. Pres. 0.0000 PSIA X - DIG. OUT 4 inact. - Wellhead P 0.0000 PSIA X - DIG. OUT 5 inact. - Temp 60.0000 DegF - X DIG. OUT 6 inact. - PI1YstTotl 0.0000 COUNTS X - DIG. OUT 7 inact. - Battery 14.6234 Volts - X DIG. OUT 8 inact. - Fixed Structure of Hardware Channels From CCU Poll (Get Status)

  6. Example of New Flexible Poll Report Based on Template Registers Date Time: 02/03/94 02:29:54 OilMeter _____________________________________________________________ OilMtrAccT 7060.0 Barrels OilMtrYstT 0.0 Barrels OIL SALES 7060.0 Barrels Lact_Pump ON WaterMeter_____________________________________________________________ WtrMtrAccT 69700.0 Barrels WtrMtrYstT 0.0 Barrels WTR DISP 69700.0 Barrels OilTanks _____________________________________________________________ API Grav 10.0 Tk1_Level 5.000 Feet Tk2_Level 3.000 Feet Tk3_Level 4.000 Feet Tk1_Valve CLOSED TK2_Valve CLOSED TK3_Valve OPEN WaterTanks_____________________________________________________________ Tk2_Level 6.000 Feet Tk1_Level 6.000 Feet Tk1_Valve CLOSED TK2_Valve CLOSED TestSeprtr_____________________________________________________________ WtrMtrKfct 9.0 BBL/Pulses OilMtrKfct 8.0 BBL/Pulses GasMtrKfct 1.0 MCF/Pulse WtrMtrAccT 35.0 Barrels OilMtrAccT 347.0 Barrels GasMtrAccT 10.0 MCF Flexible Grouping of Templated Based Registers for CCU Poll (Get Status) Reports and Spreadsheets

  7. Example of New Flexible Configuration Screen Based on Template Registers

  8. Example of DDE server reference to bothTemplate Dataand Standard FCU Config Data

  9. Template Register Map DDE Reg Number for WaterLevel = 1.2.0