90 likes | 302 Views
04.12.08 . H.Joehri. Main RequirementsEigenfrequency > 50 HzHigh internal dampingEach component can be adjusted individuallyUser independent adjustmentRepeatability of adjustments < 0.01mm for critical components Easy to adjust the level of the girder after subside of groundfloor (Without c
E N D
2. 04.12.08 H.Joehri Main Requirements
Eigenfrequency > 50 Hz
High internal damping
Each component can be adjusted individually
User independent adjustment
Repeatability of adjustments < 0.01mm for critical components
Easy to adjust the level of the girder after subside of groundfloor (Without changing the horizontal position)
Cost efficient for PSI-XFEL
3. 04.12.08 H.Joehri Basic principles
Pre-assembly of components on girders
Mechanical accuracy of components in relation to the girder, without adjustments, better than 0.1mm
Reference surfaces on the girder
Accuracy of the girder position : 0.1mm
4. 04.12.08 H.Joehri Adjustment of girder
3 feets
All feets adjustable in height and one direction
5. 04.12.08 H.Joehri
6. 04.12.08 H.Joehri
7. 04.12.08 H.Joehri
8. 04.12.08 H.Joehri