Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal iol
This presentation is the property of its rightful owner.
Sponsored Links
1 / 6

Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL PowerPoint PPT Presentation


  • 173 Views
  • Uploaded on
  • Presentation posted in: General

Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL. Ruth Lapid-Gortzak MD PhD 1,2 Ivanka van der Meulen MD 1,2 Jan Willem van der Linden Boptom . 2 1. AMC, University of Amsterdam 2. Retina Total Eye Care, Driebergen

Download Presentation

Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal IOL

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Experience with a new 4 loop haptics apodized diffractive hydrophilic multifocal iol

Experience with a new 4 loop hapticsapodized diffractive hydrophilic multifocal IOL

Ruth Lapid-Gortzak MD PhD1,2

Ivankavan der Meulen MD1,2

Jan Willem van der Linden Boptom. 2

1. AMC, University of Amsterdam

2. Retina Total Eye Care, Driebergen

Financial Disclosure: Dr. Lapid is a speaker for Alcon, Hanita Lenses, MSD, Oculentis, and a clinical investigator for Alcon. Mr. Van der Linden and Dr. van der Meulen have no interest to disclose.


Purpose

Purpose

  • To report the outcomes in terms of visual acuity, refraction, incidence of halos at 3 months after implantation with a new 4 loop haptic apodized diffractive hydrophilic multifocal IOL (MFIOL), the BunnyLens (Hanitalenses, Israel)


Methods

Methods:

Prospectiveinterventional case cohort

Standard phacoemulsification 2.2 mm incision, eitherfor cataract or refractive lens exchange.

Outcomemeasures: uncorrectedandcorrecteddistanceacuity, uncorrectednearacuity, incidence of halos, historicalcomparisonwithcohorts of apodizeddiffractivehydrophiliclenses, (SeeLens MF, Hanitalenses, Israel) apodizeddiffractivehydrophobic lens (SN6AD1, ReSTOR, Alcon), and a radiallyasymmetricrefractive IOL (LS-312 , Mplus lens, Oculentis, Germany)


Results at 3 months postoperatively

Results at 3 monthspostoperatively:


Historical comparison

HistoricalComparison

van der Linden et al, JCRS January 2012

van der Linden et al, International Ophthalmology, January 2013


Conclusion

Conclusion:

The BunnyLens MF (HanitaLenses, Israel) performswell in a small prospective cohort.

The IOL performs on par withhistorical data of otherlenses, like the SeeLens MF (HanitaLenses), the SN6AD1 (Restor, Alcon, USA), and the LS-312 (Mplus, Oculentis, Germany

The hydrophilicapodizeddiffractive type of IOL seemstoinducelessdysphotopsias, but more study is neededtoconfirmthis.


  • Login