1 / 35

Webcast Training

Webcast Training. Damiano Buscemi. Int Batt. Overview Liebert NX Product Platform. Liebert NX 380V/400V/415V - 50/60Hz. NXe. NXa. New. 10 – 15 – 20 kVA. 30 – 40 kVA. 60 – 80 kVA. 100 – 120 kVA. 140 – 160 – 200 kVA. Look and Dimensions. Compact Footprint

nansen
Download Presentation

Webcast Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Webcast Training Damiano Buscemi

  2. Int Batt Overview Liebert NX Product Platform Liebert NX 380V/400V/415V - 50/60Hz NXe NXa New 10 – 15 – 20 kVA 30 – 40 kVA 60 – 80 kVA 100 – 120 kVA 140 – 160 – 200 kVA

  3. Look and Dimensions Compact Footprint 140 to 200 kVA 700 mm (W) x 1000 mm (D) = 0.700 m2 Height 100 to 200 kVA 1800 mm Colour: Grey Silver Pantone 877 Light Weights for UPS Units 140 kVA (UPS Only) 900 kgs 160 kVA (UPS Only) 900 kgs 200 kVA (UPS Only) 1100 kgs 1800 mm 1000 mm

  4. Look and Dimensions

  5. Liebert NX: Footprint NX Net footprint600mm×700mm 600mmx825mm 1000mmx825mm Conventional UPS 600mm×(825+600)mm

  6. Liebert NX 140,160,200: UPS Unit Overview Fan for system Fans for power module DSP and detection boards Driver boards(M1) Driver board(M2) Control power supply Power modules Parallel board Fans for power module Output AC capacitors DC capacitors Input AC capacitors EMI boards

  7. Topology and General Characteristics • True On-Line Double Conversion Transformerless UPS • IGBT-based Space Vector Controlled Rectifier • IGBT-based Space Vector Controlled Inverter • Fully DSP Controlled UPS • VFI SS 111 Compliant UPS (IEC-62040-3) • Nominal Input & Output Voltage • 400 V (default factory setting) • (can also operate in 380 & 415 V) • Nominal Input & Output Frequency • 50 Hz (default factory setting) • (can also operate in 60 Hz) • (can also operate as a Frequency Converter) 10 – 15 – 20 – 30 – 40 kVA 60 – 80 – 100 – 120 – 140 – 160 – 200 kVA

  8. Liebert NX: Input Widest Input Voltage & Frequency Ranges Without Battery Help Input Voltage Range from 205V to 477V @<72% of nominal output power (typical load) @nominal power (100% load) voltage range from 305V to 477V Input frequency range from 40 to 70 Hz Unity Input Power Factor & Lowest THDi Input power factor is 0.99 Total Harmonics Current Distortion is <3%

  9. Battery Management DC-DC Switching Circuit for battery Charging & Discharging Decreased DC Voltage Ripples <1% Decreased DC Current Ripples <5% (C-10 AH Capacity) Automatic Float and Boost Charge Intelligent battery Management Flexibility in connecting various types of battery (Sealed Maintenance Free / VRLA, Nickel Cadmium & Wet type Lead Acid Batteries Temperature Compensated Charge with standard (10-40kVA) temp probes 25% Nominal Output Power for Battery Charge at Full Load Boost Charge at full load Self-diagnosis Battery capacity/backup time estimation Programmable Periodical Discharge End of discharge protection

  10. Output Clean Output DSP controlled IGBT Inverter ensures Sinusoidal Output with <1% THDV and 0.05% frequency stability Highest Capability to drive 100% Unbalanced Loads Non Linear Loads with 3:1 Crest Factor From 0,5 Lagging Up to 0,9 Leading PF Loads Great Overload Capability 110% for 60 minutes 125% for 10 minutes 150% for 1 minute

  11. Magnetics Power Modules System & Control LiebertNXa Any Other Cabinet Stratified Cooling Technique Stratified Cooling Technique Heat-generating components Power Modules Magnetics Heat-sensitive components System and controls NXa No Side or Rear Clearance needed for Thermal Management

  12. Standard Parallel Board And Redundant Power Supply Card Standard Parallel Board Battery (Black) Start Kit (Optional) Standard & Redundant Power Supply Card Service Power Socket Power Supply Card Battery Ground Fault Detection Kit (Optional)

  13. IntelliSlots & Air Filters MMI Card & the LCD Panel 3 Intellislots (provision for Simultaneous Communication) Removable Air Filters (at the inside of the door)

  14. Simultaneous Communication 3 Simultaneously Communicating Intellislots Relay Cardfor Location Supervisor / User SNMP OCWEB-LB Cardfor Network Manager ModBus / Jbus Cardfor Facility Manager RS-232 & RS-485 Ports Available

  15. Control Panel & LCD Display User friendly Control Panel Micro-processor Controlled LCD Display 320 x 240 dots graphic Information on Main Input Bypass UPS Output Local Load Information Parallel Load Information Battery Status Power Flow Mimic Load Level & Overload Condition Alarms & Status Information Inverter ON/OFF Switch No special training needed for Operators Makes it easy to understand Load and Source conditions Easy, first hand diagnostics

  16. UPS System Window 12:30:36 2003-01-22 PARADIGM Unit #1 Normal 60kVA-3X3 UPS Menu Window Main Bypass Output UPS Data A(AB) B(BC) C(CA) Window Vphase V 220 220 220 Iphase A 20.5 20.5 20.5 Freq. Hz 50.1 50.1 50.1 Vline V 380 380 380 Current Record 0.99 0.99 0.99 P. F. Window Input Breaker Closed 01-12 12:28:16 Manual Turn On 01-12 12:30:06 Keypad UPS in Normal Mode 01-22 12:30:16 Window ? F1 F2 F3 F4 F5 User Friendly Interface Easy to use Large screen LCD display Fluorescent Back-lit Contrast-adjusting 5 Keys (for navigation) 5 Windows 12 Languages Derived Parameters 512 Event Log System Data

  17. Wide Choice of Configurations ≤15m Liebert NX System Liebert NX System

  18. Extended Dual Bus NX150MLBSKIT NX050MLBSKIT Source 2 Source 1 ≤150m Liebert NX System Liebert NX/ Non Liebert NX System

  19. Liebert NX : Other Important Features EMC Class-A Filter For the standard unit Back-Feed Protection Sensing & Signaling are standard Upstream circuit breaker to be provided by the customer Fan Failure Indication For the standard unit DSP Control Technology ensures Easy Precise and Reliable Parallelling Built in Load Bus Synchronization And Parallel Boards Internal redundant components Power Supply Cards, Opt 100% redundant funs Optional Bypass load sharing inductors

  20. External Options

  21. External Options Circuit Breaker Box 140 and 160kVA NXA0BCB146 200kVA NXA0BCB200 825 mm NXA0BCB146 NXA0BCB200 180 mm 195 mm 530 mm

  22. External Options Battery Cabinets NXA0NBCL (Large Battery Cabinet) With Optional Circuit Breaker/Fuse Kit* Optional Temperature Sensor Kit *Available soon 1800 mm NXA0NBCLXX 825 mm 825 mm 1490 mm 100 – 120 – 140 – 160 – 200 kVA

  23. External Options Bypass Cabinets And Transformer Cabinets Provided with connection to UPS monitor Board Dimensions depending on the kVA and number of parallel units Designed and manufactures on request 1600 mm 1600 mm 1600 mm 825 mm 825 mm 825 mm 800 mm 850 mm 600 mm

  24. Competition Offer

  25. Socomec Delphys MP Delphys MP/MP elite Two Rectifier versions SCR and IGBT based From 60 to 200kVA Less than 2.5 THDi Up to 0.9 Leading PF loads Fun Redundancy Footprint 1000x800mm Output Voltage Distorsion <2% Input Voltage Window 340 – 460V Input Frequency Window 45 – 66Hz Noise Level 68dBA

  26. MGE Galaxy 6000 Galaxy 6000 Trafo Based DSP PWM Based From 160 to 800kVA Less than 4% THDi with Harmonic Filter Output Voltage Distorsion <3% Input Voltage Window 320 – 470V Input Frequency Window 45 – 66Hz Parallelable up to 6 (4 without MSS) Noise Level 68dBA @ 200kVA Footprint 1800x850mm

  27. Powerware 9390 9390 DSP PWM Based From 80 to 160kVA Less than 4% THDi with Harmonic Filter Efficiency 94% HotSync feature Footprint 519x804mm Output Voltage Distorsion <3% Input Voltage Window 330 – 480V (280 – 480V) Input Frequency Window 45 – 65Hz Loads from 0.7 lag to 0.8 leading PF Noise Level 70dBA @ 160kVA

  28. Chloride 90-NET Chloride 90-Net SCR Rectifier Input Freq Range 47.5 – 63% Input THDi 5% with Low THDi option Noise Level 64 dBA Width 1020x830 mm

  29. Available Literature

  30. Liebert NX 140-200kVA Literature Brochures & collateral Liebert NX 10-200kVA Brochure Liebert NX 30-200kVA Technical Specs Liebert NX 30-200kVA Guide Specs Liebert NX 30-200kVA User and Installation Manual Liebert NX 30-200kVA Product Presentation Liebert NX 30-200kVA System Guide NEW! Liebert NX 10-200kVA Poster NEW!

  31. Translating Features into Values you can sell

  32. Orders and Availability

  33. Liebert NX 140-200kVA Availability Liebert NX 140,160,200 kVA is orderable from now Stock Model Aug Sept 140 kVA 1pcs 2pcs 160 kVA 8pcs 14pcs 200 kVA 6pcs 13pcs

  34. Questions

  35. Thank You!

More Related