1 / 32

Correction and Preprocessing Methods

Correction and Preprocessing Methods. Veselin Dikov Moscow-Bavarian Joint Advanced Student School 19-29. March 2006 Moscow, Russia. Outline. Beam hardening Scattered radiation Ring artefacts References. Beam hardening. Monochromatic vs. Polychromatic X-ray source

msmart
Download Presentation

Correction and Preprocessing Methods

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Correction and Preprocessing Methods Veselin Dikov Moscow-Bavarian Joint Advanced Student School19-29. March 2006 Moscow, Russia

  2. Outline • Beam hardening • Scattered radiation • Ring artefacts • References

  3. Beam hardening • Monochromatic vs. Polychromatic X-ray source • Absorption of low energy photons • Additive detector • Mean energy higher - beam hardening

  4. Thickness measurement • Monochromatic • Polychromatic for homogenous medium

  5. Thickness measurement • “Non-linear” deviation of the polychromatic signal

  6. Beam hardening artefacts • Cupping • Simulated skull

  7. Beam hardening artefacts • Streaks • Hard (e.g. bone) tissues

  8. Correction Strategies • Preprocessing • On projection data • Postprocessing • On reconstructed data • Dual-energy imaging • Considered most elegant

  9. Preprocessing • Select “appropriate” absorber • Measured value A is corrected to A’ • Assumes “homogeneous” medium • Fails if bone present

  10. Postprocessing • Iterative approach: • first: preprocessing step • second: threshold to identify hard structures • third: forward-project the contribution of the hard structures into projection data • Good results

  11. Dual-energy image • Modeling of the attenuation coefficient • Substitute in • Gives

  12. Dual-energy image • Two energies - two integral equations • Reconstruct and • Now can be reconstructed for any E • Two scans?

  13. Outline • Beam hardening • Scattered radiation • Ring artefacts • References

  14. Scattered radiation • Scattered radiation • Components of scatter • Off-focus radiation (OFR) • Scattered radiation in the patient • Veiling glare

  15. Scatter measure • SPR – Scatter-to-Primary-Ratio • Broad beam model estimation for SPR

  16. Scatter artefacts – loss of contrast • Loss of contrast • Contrast without scatter • Contrast with scatter

  17. Scatter artefacts – loss of sharpness • Loss of sharpness • Transmitted radiation • - blurring kernel • - 2D convolution

  18. Scatter artefacts – loss of sharpness • Loss of sharpness • Veiling glare contribution

  19. Scatter reduction methods • Anti-scatter grids • 4G vs. 3G • Higher voltage • Air gaps • Magnifying effects • Increased blurring • Beam collimation • Complicated systems reminder:

  20. Measurement of scatter • Opaque disc techniques • Scatter in the “shadow” • Arrays of discs with decreasing size • Aperture techniques • Narrow beam “clean” of scatter • Arrays of apertures • Hybrid techniques • One vs. Two scan techniques

  21. Correction schemes - Convolution Filtering • Detected image • Use as an estimation for • Spatial vs. frequency domain filtering • Analytical vs. empirical approaches for filtering schemes

  22. Correction schemes – Scatter sampling • Sampling of the scatter measurement • Opaque discs arrays • Aperture grid • Interpolation of the smooth surface • -6 dB

  23. Correction schemes – Scatter sampling • Interpolation schemes • 2D least squares fitting • Filtration with sinc and jinc • 2D polynomial fitting • 2D bicubic splines • Sampling rate depends on surface frequencies

  24. Results

  25. Outline • Beam hardening • Scattered radiation • Ring artefacts • References

  26. Ring artefacts

  27. Ring Artefacts • Reason • 4G vs. 3G • Postprocessing correction only

  28. Correction scheme • ROI • I P • Artefact pattern • Artefact subtraction • P I

  29. ROI • Select ROI with morphological operations

  30. Find artefact pattern • Scan for irregularities • Use variance of signal • or Use median of signal • etc. • Extract ring pattern

  31. Results

  32. References • T.Buzug, Einfürung in die Computertomographie, Springer-Verlag (2004) • A.Kak and M.Slaney, Principles of Computerized Tomographic Imaging, IEEE Press (1988) • K.P.Maher and J.F. Malone, Computerized scatter correction in diagnostic radiology, Contemporary Physics 38, 131-148 (1997). • J.Sijbers and A.Postnov, Reduction of ring artefacts in high resolution micro-CT reconstructions, Physics in Medicine and Biology Vol. 49 (07/2004) • M.Zellerhoff et al, Low contrast 3D-reconstruction from C-arm data, Medical Imaging SPIE, 646-655 (04/2004) Thank you for your attention!