An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THEMIS PROBE • FM2 PRE-ENVIRONMENTAL REVIEW • EMC Test • Dave Curtis • System Engineer • University of California - Berkeley

  2. Test Requirements • Launch Site Requirements • Test in Launch configuration with instruments off • RE02, RS03 per THEMIS ICD with Boeing • Self Compatibility Requirement • Test in plugs-out configuration with instruments on • RE02, RE04, RS03 per THEMIS Environmental Spec • Limit RE02 to science sensitivity band, 20Hz-1MHz, plus the probe receiver band 1.7-2.3GHz • Limit RS03 to probe transmitter band. Also power up transmitter to verify self-compatibility. • Test Procedures in sign-off: • THM_MINT_041. UCB Test Procedure • THEMIS_EMC_TP. JPL Facilities Procedure

  3. Launch Site Levels Launch Mode RE02 Limit

  4. THEMIS RE02 Levels

  5. THEMIS RE04 Levels

  6. JPL EMC Facility

  7. JPL EMC Facility • Facility EMI background meets THEMIS requirements • Will have to look between 60Hz harmonics for RE04 • Low frequency RE02 (<14kHz) on a best effort basis • Facility test equipment adequate for THEMIS measurements • Frequency range, sensitivity, power, etc. • Facility size adequate for Probe and EGSE • see following section on layout of test • Probe will be fork-lifted into facility on roll-around stand (no crane) • Facility cleanliness level can meet THEMIS requirements • has been demonstrated on previous project

  8. Launch Mode Setup • Probe connected to EGSE via Umbilical • Instruments Off (Launch Mode) • Launch Site Test Levels (RE02, RS03)

  9. Operational Setup • Probe connected to EGSE via RF (Hat) • Instruments On (Operational Mode) • THEMIS Science Test Levels (RE02, RE04, RS03)