Temperature Handheld. WIKA Calibration Line Pressure Hand-Helds Signal Calibrator Hand-Helds Temperature Hand-Helds. Temperature Indicator. CTH6500 CTH6510. Hand-held thermometers 手持式温度仪 测量范围 : Pt100: —200 °C ... +600 °C / TC: 可达 1500 °C Choice of 1 or 2 inputs 用于湿度和流量测量的特殊探针

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Temperature Handheld' - mea


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

Temperature Handheld

  • WIKA Calibration Line

  • Pressure Hand-Helds

  • Signal Calibrator Hand-Helds

  • Temperature Hand-Helds


Temperature indicator
Temperature Indicator

CTH6500

CTH6510

  • Hand-held thermometers手持式温度仪

  • 测量范围: Pt100: —200 °C ... +600 °C / TC: 可达1500 °C

  • Choice of 1 or 2 inputs

  • 用于湿度和流量测量的特殊探针

  • Special probes for humidity and flow measurements

  • 精度: Pt100: 0,03 K ----------50 °C 到200 °C, 更高温度下0,05 %

  • TC: 0.2 K to 1 K, rF: 1.5%rF

  • 显示分辨率: 0.01 °C ------200 °C以下, 更高温度为0.1 °C

  • 环境温度: 0 °C ... 40 °C 信号接口: USB

  • 电源: 9 V 电池提供作为直流电源DC9V battery

  • 数据记录: 可记录多大6000个数据optional capacity for 6000 values Data logger


  • Hand held thermometer cth6500 cth65i0

    Temperature Hand-Helds

    Hand- Held ThermometerCTH6500CTH65I0

    • Digital instrument ( 1 or 2 channel version) for Pt100 – probes and TC probes

    • Sensors (Pt100, TC), range -50 °C…1.760°C

    • “Plug and Play”

    Range

    • Pt100: -200°C to 850°C

    • TC - J, K, N, R, S, T and L: according to IEC 584 / DIN

      Uncertainty

    • Pt100: 0,05 K

    • TC: 0,3 K

      Application

    • calibration labs, measurement and control

    • workshops, industrial applications


    Cth6500 application

    Temperature Hand-Helds

    CTH6500 application


    Hand held thermometer
    Hand-held thermometer

    CTH6200

    • Measuring range -50⁰C to +250⁰C

    • Accuracy than 0.2K with option to 0.05K

    • Sensor type: Pt100


    Accessories data logger software gsoft

    Temperature Hand-Helds

    Accessories - Data logger Software GSoft

    - pressure and temperature in one graph

    - creates tables & XY-graphs

    - remote operation of logger via PC

    - data can be exported to Excel


    Hand held cth 6200

    Temperature Hand-Helds

    Hand- Held CTH 6200

    • Digital Instrument (1 channel version) for Pt100 – Probes

    • CTP62x0: -50…250°C

    • „Plug and Play“

    PLUG

    &

    PLAY

    certified

    accuracy

    Logger inside


    Infrared hand held thermometer

    Temperature Hand-Helds

    Infrared Hand-held Thermometer

    CTR1000

    • Thermocouple connection possible

    • Measuring range: -60⁰C to +1000⁰C

    • TC: -64 °C ... +1370 °C

    • Accuracy: 2K or 2% of reading

    • Accuracy: TC: 1 K or 1% of rdg.

    • Display resolution: 0.1 °C up to 200 °C, then 1°C

    Data Sheet CT 55.21


    Infrared hand held ctr1000

    Temperature Hand-Helds

    Infrared Hand-Held CTR1000

    • Non contact measurement in the range - 60…1000°C

    • Easy and safe measurement of surface temperatures

    • Different distance to spot ratio

    • Min/Max function

    • Hold function

    • Data logger

    • High-/Low- Alarm

    • TC connection


    Areas of application

    Temperature Hand-Helds

    Areas of application

    Infrared Hand-Held CTR1000

    • Non-contact surface temperature measurement

      • on moving objects

      • on rotating parts

      • on aggressive substances

      • hot surfaces

      • on small components

    • Checking of electrical contacts

    • temperature measurement at electrical conductors under high voltage

    • Testing of electrical components and devices


    ad