1 / 32

Casa Systems

Casa Systems. SCTE. Joe Beecher Royce Salazar. 25 August, 2016. Agenda. Who are we ? What is CCAP? Space Power Kilo watt savings Indirect savings, cooling OAM Simple configuration Wire once/Single management Case Study Miles of coax saved Video Encryption Future IPTV

mattier
Download Presentation

Casa Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Casa Systems SCTE Joe Beecher Royce Salazar 25 August, 2016

  2. Agenda • Who are we ? • What is CCAP? • Space • Power • Kilo watt savings • Indirect savings, cooling • OAM • Simple configuration • Wire once/Single management • Case Study • Miles of coax saved • Video • Encryption • Future • IPTV • Distributed CCAP Architecture SCTE Rocky Mountain Chapter August 2016

  3. At a glance • Casa Systems A Glance @Casa Systems • 2003 Founded • Headquartered in Andover, Massachusetts, USA Headquarters • Subsidiaries in Canada, China, Netherlands, and France • Manufacturing in the US • R&D / Customer Support in USA and China Global Footprint Customer Base • Serving MNOs, MVNOs, MSOs and Fixed Service Providers Number of Employees • 500+ Employees worldwide Our Business • Technology solution provider to telecommunications and networking industries, specializing in ultra broadband Track Record • Over 300 live deployments around the globe, supporting millions of subscribers SCTE Rocky Mountain Chapter August 2016 • Summit Partners, a growth equity firm w/ $15B under management • Liberty Global Inc. • Founders and employees Our Investors

  4. Manufacturing • All products are developed and designed by Casa Systems. • Component manufacturer and vendor selection for critical components directed and managed by Casa Systems. • Vendors/distributors required tostock critical, long lead timecomponents to ensure supply. • Components are purchased by contract manufacturers and/or by Casa Systems. • Manufacturing quality and testing is approved and monitored and/or performed by Casa Systems. • Contract manufacturing located in the US & provided by: • Benchmark Electronics for chassis products (NH) SCTE Rocky Mountain Chapter August 2016

  5. CCAP Goals • Operational improvements • Environmental efficiencies (e.g. reduced space, power consumption, and heat dissipation) • Increased DS and US density • Flexible use of QAM channels for various services through a single configuration point • DOCSIS-based services (e.g. High Speed Internet, voice, IPTV) • MPEG transport stream-based services (e.g. for VOD, SDV) • Linear Broadcast service • Individually configurable assignment of QAM channels to various service groups • DOCSIS SGs, VOD SGs, and SDV SGs overlap in different ways without requiring that these SGs be identical • Efficient implementation of separate sets of QAM channels for narrowcast and broadcast applications • QAM channels for narrowcast services can be individually implemented for each RF port • QAM channels for broadcast services can be shared among the RF ports in each downstream card • Simplification of the RF combiner network • Providing QAM channels for all digital services from a single RF port • Transport-agnostic network architecture allowing implementation of EPON • CCAP will be expected to support EPON in the future with pluggable components SCTE Rocky Mountain Chapter August 2016

  6. CCAP – Platform Implementation • CCAP can be implemented as a single Integrated CCAP chassis or implemented in a modular fashion • Modular CCAP • Consists of more than one device • A single Packet Shelf – contains the packet processing functions, such as subscriber management, service flow management, layer-3 routing and higher level protocol manipulation • One or more Access Shelves - contains the upstream and downstream PHY functions normally associated with the CMTS and the edge QAM, and nearly all of the DOCSIS MAC • Integrated CCAP • Support all the CCAP requirements in one device • Easier to manage • No interoperability issues with multiple devices SCTE Rocky Mountain Chapter August 2016

  7. CCAP Benefits • Bandwidth Capacity and Density Gains • CCAP is designed to greatly increase the capacity of the device, delivering all narrowcast and broadcast services via the downstream RF ports deployed • Casa DS 8x96 module supports 256 narrowcast channels and 64 broadcast channels • Customers can benefit for the high density DS modules even if they don’t have edge QAM applications • Rack Space and Power Reduction • CCAP has strict requirements on power consumption and rack space • High density results in fewer equipment • CCAP provides support of DOCSIS and Edge QAM applications. As a result, fewer equipment will be required in the Headend • Service Multiplexing Flexibilities • QAM channels for narrowcast services are individually implemented for each RF port • QAM channels for broadcast services are shared among all the RF ports in each downstream card • The number of narrowcast and broadcast QAMs supported on each RF port is flexible • Same narrowcast video QAM can be mapped to multiple downstream ports, allowing for overlap of SDV and VOD service groups • Allow configuration of any QAM in a given CCAP RF port for DOCSIS or Edge QAM applications -> Provide the ability to transition from legacy Edge QAM applications to next generation video services (e.g. IPTV via DOCSIS) SCTE Rocky Mountain Chapter August 2016

  8. CCAP Benefits (cont’d) • Configuration and Management Simplifications • The CCAP will allow configuration of both CMTS and Edge QAM functions from the same configuration interface • CCAP will move away from SNMP-based configuration and focus on the processing of XML configuration files • Local storage and versioning of configuration files aids rapid recovery of services when a primary component has failed • RF Combining Simplifications • Provide all QAM channels for all digital services from a single RF port (only leaving certain legacy functions for RF combining) • Rather than having to rewire the physical plant to make service group changes, the QAM content of a downstream RF port can be changed via the CCAP configuration interface • IP Router Integration • CCAP specification requires to support a wide range of IP applications • Easy migration path from legacy MPEG-TS to IPTV over DOCSIS SCTE Rocky Mountain Chapter August 2016

  9. CASE Study Business/Technical Goals • Channel bound – 8ch DS maximum capacity • Goal was to offer 300MB service 16ch DS • Space limited – need much denser solution to meet current and future requirements • Power – reduce power consumption by 20-30% • Speed – need to replace 400+ legacy CMTS with CCAP within eight months SCTE Rocky Mountain Chapter August 2016

  10. CCAP Environmental efficiencies Actual Deployments vs CCAP 160 HSI service groups, and 120 VOD and matching SDV service groups. Considering typical CMTS and Edge QAM equipment available today, this service group configuration would require about 10 CMTS chassis and about 4 racks for VOD and SDV, each containing 6 Edge QAM chassis configured for 64 QAM channels, each at a density of 4 QAM channels per RF port. The digital broadcast lineup is composed of 60 individual QAM channels, plus the corresponding out-of-band equipment. SCTE Rocky Mountain Chapter August 2016

  11. Converged Cable Access PlatformCCAP CMTS HSD CASA C100G CCAP HSD VOD SDV VOD Video on Demand SDV Switch Digital Video SCTE Rocky Mountain Chapter August 2016

  12. Real DeploymentBefore CCAP VOD SDV CMTS SCTE Rocky Mountain Chapter August 2016

  13. Real DeploymentAfter CCAP SCTE Rocky Mountain Chapter August 2016

  14. Session Based Video Applications SCTE Rocky Mountain Chapter August 2016

  15. Session Based (VOD & SDV) Video Session Setup SRM Session Resource Manager EDIS (Video Session Setup) CREATE C100G Channel Change Request VOD Request VOD Server STB IP UDP Unicast SPTS MPEG-2 1518 byte VOD MPTS MPEG-2 188 Bytes SDV MPTS MPEG-2 188 Bytes IGMP Join/Leave Upstream Router STB IP UDP Multicast SPTS MPEG-2 1518 byte Externally combined Broadcast SDV Server Serving Group SCTE Rocky Mountain Chapter August 2016

  16. Session Based (VOD & SDV) Video Session Setup SRM Session Resource Manager EDIS (Video Session Setup) CREATE C100G VOD or Channel Change Request VOD Server STB IP UDP Unicast SPTS MPEG-2 1518 byte VOD MPTS MPEG-2 188 Bytes SDV MPTS MPEG-2 188 Bytes IGMP Join/Leave Upstream Router STB IP UDP Multicast SPTS MPEG-2 1518 byte Externally combined Broadcast SDV Server Serving Group SCTE Rocky Mountain Chapter August 2016

  17. Session Based Overview • Each new VOD or SDV session generates a CREATE from the SRM. • When session ends SRM sends a DELETE to remove session. • VOD is unicast and SDV is multicast • Protocol has 2-way handshake for all messages. • Supports Video on a per session basis. • All topology information and changes must be manually exported to the SRM. This was done to simplify protocol exchange with the SRM. SCTE Rocky Mountain Chapter August 2016

  18. Session Based Configuration video edis1  Host SRM Configuration ip-address 98.19.16.55  Optional if reported by SRM srm-type casa announce reset-indication interface video 1  Video Input Configuration ip address 199.209.1.1 255.255.255.255 input-port-id 1 video qam-domain 1  Video Output Configuration edis 1 video service group 1 interface video 1 qam-group 1 4/0/0 4/0/31  Range of QAM channels SCTE Rocky Mountain Chapter August 2016

  19. Video QAM Domain Configuration video qam-domain 1 edis 1 video service group 1 interface video 1 qam-group 1 4/0/0 4/0/31 qam-group 2 4/1/0 4/1/31 qam-group 3 4/2/0 4/2/31 qam-group 4 4/3/0 4/3/31 interface qam 4/0 interleave 128x1 power 480 channel 0 frequency 57000000 channel 0 transport stream id 11024 no channel 0 shutdown channel 1 frequency 63000000 channel 1 transport stream id 11025 no channel 1 shutdown SCTE Rocky Mountain Chapter August 2016

  20. Broadcast Video • Broadcast capability is supported using shared channels • MPTS input and output. • 96 QAM channels shared across 8 ports. • 960 Standard Definition Video channels. SCTE Rocky Mountain Chapter August 2016

  21. Broadcast Video • 96 Shared QAMs present on each of the 8 ports on the DS8x96. C100G VOD MPTS MPEG-2 188 Bytes DS8x96 SG 1 SG 2 SG 3 IP Multicast MPTS MPEG-2 1518 byte SG 4 DVB Server SG 5 SG 6 SG 7 SG 8 Serving Groups SCTE Rocky Mountain Chapter August 2016

  22. Integrated Full CCAP Solution • One device to Procure, Deploy, Manage and Operate • Resource Efficient; • Less Rack space • Less Power and Cooling • Faster Time to Deployment and get to Deployment Readiness • Reduction of Complexities in a HA environment • Fewer Components to fail • Higher density per RU • Lower Service charges due to Fewer Solution Components SCTE Rocky Mountain Chapter August 2016

  23. EncryptionCAS • Bulk encryption • Netcrypt • DCM • Edge Encryption • Privacy Mode Encryption (PME) (Motorola) • DVB Simulcrypt • PowerKey Encryption (PKE) (Cisco/SA) • CCAP encryption SCTE Rocky Mountain Chapter August 2016

  24. CMTS Engineering Playbook Example: New Deployment for 40 Service Groups 2US:1DS Casa Systems C100G HW • (5) 8x96 /Slots 0-4 • (1) 8x96-redundant card /Slot 5 • (5) 16x8 /Slots 9-13 • (1) 16x8-redundant card/Slot 8 • (2) SMM /Slots 6 and 7 • (2) PEM (Power Entry Module) • Power Consumption: ~3774 W • BTU/HR 12,871 Casa Systems C100G SW • 6.4 Edge QAM HW Supported Up to 8 US per port / 16 per SG Bonding across US16x8 LC Up to 44 DS DOCSIS & Narrowcast Video QAM per SG/port PEM PEM 40 SG per Single Chassis 2US:1DS Redundant/High Availability The LC and SMM switch modules MUST be installed in their specific chassis slots, and ALL four slots (5,6,7 and 8) must be occupied for redundancy operations. Both modules are appropriately labeled for identification; either LC SWITCH or SMM SWITCH. SCTE Rocky Mountain Chapter August 2016

  25. Background - NYC • In 2014, TWC began a multi-year plan to consolidate its CMTS and Edge QAM architecture to provide higher speeds to the customer • Converged Cable Access Platform HSD High Speed Data CCAP CMTS VOD Video on Demand SDV Switched Digital Video • * In 2013, the Manhattan system was converted from Big Band to NSG for space saving reasons. For this study, we will measure from the NSG on. • Note: Linear broadcast is not currently planned to migrate to CCAP SCTE Rocky Mountain Chapter August 2016

  26. Power and Productivity Scenarios & Financial Benefits Legacy CMTS will consume an additional 597KW for all 25 sites • CCAP will consume an average 30% less power while enabling almost double (93%) the productivity (higher bandwidth) across all 25 sites CCAP will save 313KW for all 25 sites SCTE Rocky Mountain Chapter August 2016

  27. New York City 2X VOD QAMS 2X HSD QAMS SCTE Rocky Mountain Chapter August 2016

  28. Power Comparison • Engaged NYSERDA, they provided engineering firm Willdan to assist in data capture and analysis • New York State Energy Research and Development Authority • Watts and QAM count were key to the metric Less Efficient Efficient • Note: • This analysis is based solely on TWC configurations and is not an exhaustive list of hardware SCTE Rocky Mountain Chapter August 2016 • CCAP capable

  29. Queens Example • Legacy • 26 SDV Arris D5 • 132 VOD (SA GQAM) • 21 HSD (Arris C4) CCAP 41 CASA Units • Potential Savings • Direct reduction of IT load • Indirect Savings from UPS and cooling power savings from reducing load • Average savings SCTE Rocky Mountain Chapter August 2016

  30. CCAP Effect • Total Power Savings across 25 sites SCTE Rocky Mountain Chapter August 2016

  31. Summary Benefits • Space savings (30% average reduction in space) • Facility capacity investment offset • Infrastructure improvements would’ve been required to support incremental growth • Simplified RF combining network • Estimated saved in NYC sites: • ~750,000 feet of Coax copper cable • ~75,000 connectors • ~12,000 passives • Simplified device management • Helped continued transition to DC power SCTE Rocky Mountain Chapter August 2016

  32. Delivering unique, ubiquitous, ultra broadband solutions that transform our world – from the edge to the core SCTE Rocky Mountain Chapter August 2016

More Related