Ies 5000 introduction
Download
1 / 58

IES-5000 Introduction - PowerPoint PPT Presentation


  • 144 Views
  • Uploaded on

IES-5000 Introduction. ZyXEL Communication Anders Opsahl ( [email protected] ). Agenda.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' IES-5000 Introduction' - mason


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Ies 5000 introduction

IES-5000 Introduction

ZyXEL Communication

Anders Opsahl ([email protected])


Agenda
Agenda

- Info om IES-5000 * Antall og typer linjekort * User Management* Firmware-upgrade - Config * Backup / restore / save - Port-setup * Åpne / stenge porter * Lage profil, og sette profil på port(er) * Hands on*- VLAN og IP * Sette IP og gateway, samt MGMT-VLAN * Fixed og untagged, samt PVID * PVC-setup * Hands on*- Enkel feilsøking * Hva om det ikke går trafikk på en port? * Linjekort ikke blir active



Ies 5000m front view
IES-5000M Front View

10 Slots Chassis

Fan Module

-48 VDC Input

MSC module

Line card

6.5 U


Msc1000g front view
MSC1000G Front View

ACO

Alarm

Console

port

SPF modules

1000 Base T

Ethernet

Out-of-band Management

VLAN Unaware


Typer linjekort
Typer linjekort:

  • ALC-1248G-53

  • SLC-1248G-22

  • SLC-1348G-22

  • VLC-1324G-53

  • VLC-1348G-53

  • ELC-1220G-55


Typer linjekort1
Typer linjekort:

ALC-1248G-53

  • Teknologi

Generasjon

Porter

Backplane

Chipset

Annex


Typer linjekort2
Typer linjekort:

SLC-1248G-22

  • Teknologi

Generasjon

Porter

Backplane

Chipset

Annex


Typer linjekort3
Typer linjekort:

  • ALC-1248G-53

  • SLC-1248G-22

  • SLC-1348G-22

  • VLC-1324G-53

  • VLC-1348G-53

  • VLC-1424G-56

  • ELC-1220G-55


Alc1248g 51 53 front view
ALC1248G-51/53 Front View

Power

LED

Telco 50 connecter

ALC1248G-51

System

LED

Console port

Alarm

LED


User management
User Management

  • WEB-GUI

  • Telnet

  • FTP

  • SSH

  • SNMP

  • Console

  • Out-of-band MGMT-port(default IP: 192.168.0.1)

Management IP og VLAN


User management cnt
User Management (cnt.)

  • Support multi-users & multi-privilege

  • - Up to 16 user account

  • 3 level user privileges

  • - Low: read only

  • - Middle: read/ write

  • - High: read/ write/ user management

  • Support remote authentication (RADIUS)

  • On-line user information


User management cnt1
User Management (cnt.)

  • Telnet & SSH session

    • share 4 sessions

  • FTP & SFTP session

    • share 1 session

  • Up to 3 Web sessions supported

    • one session per user account


Firmware fw
Firmware (fw)

  • Kommer i revisions

  • En revision inneholder siste fw til alle kort

  • ftp://ftp.dsl-partner.no/

  • V3.95(LU.0)C0

  • V3.95(LU.1)b1

  • V3.95(LU.0)_0905


Firmware upgrade
Firmware upgrade

3 måter å legge opp firmware på:

  • WEB-GUI

  • FTP

  • Console










Port setup via telnet
Port-setup via telnet

IES-5000> port adsl set

Usage: set <slot-port> <profile> <mode><slot-port> : example 3-*, 3-3~5,10~15<profile> : adsl profile name<mode> : gdmt, etsi, auto, adsl2, adsl2+

IES-5000> port adsl set 4-1~10,15~20 Max auto


Port setup via telnet1
Port-setup via telnet

IES-5000> port enable

usage: enable <slot-port>

<slot-port> : example *-*, 3-*, 3-1,3~5,10~15

IES-5000> port enable *-*

IES-5000> port enable 3-*

IES-5000> port enable 3-1,3~5,10~15


Config
Config

IES-5000> config save


Backup
Backup

ftp> get config-0


Hands on
Hands on

  • Last ned siste fw fra ftp

    ( ftp://ftp.dsl-partner.no/ )

  • Oppgrader alle kort til siste fw

  • Lag en ADSL-profil kalt “DSLAM-kurs”

  • Hastighet på profil: 15Mbit ned / 1Mbit opp

  • Sett profilen på port nummer 8 på et ADSL-kort

  • Enable port 8 og sjekk sync

  • Config save



FilteringDatabase

ForwardingProcess

Ingress Rule

Egress Rule

PacketReceive

PacketTransmit

802.1Q Processs


Ingress rule
Ingress Rule

Tagged frame

Tagged frame

VID

VID

Ingress Rule

Tagged frame

Untagged frame

PVID




Sette ip og vlan1
Sette IP og VLAN

IES5000> ip set

usage: set inband <ip>[/<netmask>] [<inband-vid> <gateway-ip>]

set outband <ip>[/<netmask>] [<gateway-ip>]

<inband-vid> : inband management vlan id

<gateway-ip> : default gateway ip

IES5000>

IES5000> ip set inband 212.125.177.8/26 1 212.125.177.1


Sette ip og vlan med forsikring
Sette IP og VLAN med “forsikring”

IES5000> sys reboot 300

telnet-1(212.125.177.2) has initiated reboot, system reboot in 300 seconds!

IES5000> sys reboot cancel

telnet-1(212.125.177.2) has cancelled system reboot!


Pvc permanent virtual circuit

PVC – Permanent Virtual Circuit


Permanent virtual circuit
Permanent Virtual Circuit

  • PVC is used to create a logical traffic interface

  • Support various PVC for multiple services

  • PVC Categories:

    • PVC - VLAN Bridging

    • PPVC - 802.1p Priority to ATM QoS mapping

    • PAEPVC - PPPoA forwarding

    • TLSPVC - Transparent VLAN Service

    • DTPVC – Double tag PVC


Bridging pvc
Bridging PVC

  • Up to 8 PVC per DSL port

  • Each PVC in IES-5000 is a super PVC (IES-2000/3000)

    - Can join multiple VLAN

  • Each PVC is able to accept and receive

    - Tag Frames

    - Untagged Frames

  • Each PVC has its own

    - Default VLAN

    - Default Priority

  • Four Priority queues

    - Applies in single PVC only

    - Strict priority


Bridging pvc with vlan trunking
Bridging PVC with VLAN trunking

  • One PVID/default priority within this PVC

  • One PVC can join multiple VLANs

This PVC joins VLAN 1,2,3

PVID = 1, priority=0

DSLAM

Untagged with PVID=1

VLAN 2

VLAN 3

Tagged Frame,

VLAN 2, & VLAN3

0/33

CPE


Pvc application

IES-5000

DSL Port 1

PVC Application

Tagged frame

VID=1

Internet

Ethernet Port

Internet Access

VLAN 1

802.1Q VLAN

Switch

Tagged frame

VID=2

Untagged frame

PVID =1

0/33

Untagged frame

PVID =2

0/34

Video Server

VLAN 2

CPE

PC

TV


Configurations multiple pvcs
Configurations- Multiple PVCs

Step 1: Default Virtual (VPI/VCI)

Step 2: Add new PVC-info

Step 3: Final result


Hands on1
Hands on

  • Opprett VLAN 100, sett Fix / Tag på uplink

  • Sett IP: 192.168.100.x / 255.255.255.0

  • Gateway: 192.168.100.1

  • Sett management VLAN 100

  • Lag en PVC med VPI/VCI: 8/35, PVID 100

  • Slett default PVC (0/33)



Ikke trafikk p en port
Ikke trafikk på en port

Er port active? (Port setup)

Er det sync på port? (Port statistics)

Er MAC-addressen til modem i riktig VLAN? (MAC-table, PVID)

Brukes riktig VPI/VCI –verdier? (Vises MAC-adresse er dette korrekt)


Linjekort
Linjekort

Nytt kort blir ikke active? (For gammel firmware på linjekort?)

Ny type linjekort satt inn i sentral? (Siste fw på MSC-kort?)

Kort som har virket, er ikke lenger active? (Lcman enable)


Adsl2 fall back
ADSL2+ fall back

  • ADSL2+ fall back

  • Bi-directional AAL5 ATM VCs

  • PPPoA and IPoA

  • PVC to VLAN mapping


Dsl operational mode
DSL operational mode

Select the port’s DSL operational mode as “adsl2+”, or “auto” to have the IP DSLAM automatically determine the mode.




Lab adsl2 fallback

10.0.0.x/24

Lab - ADSL2+ Fallback

10.0.0.1/255.255.255.0

0/33 VID = 14

ADSL2+ CPE


SHDSL

ATM g.bond


Shdsl g bond
SHDSL g.bond

  • Bundling metoder:

    • 4-wire

    • Mpair4

    • G.bond



Lab atm g bond
Lab – ATM g.bond

IES-5000

VID = 100

IES-708


Lab atm g bond1
Lab – ATM g.bond

PC VLAN 200,

IP: 192.168.200.1

DHCP-server VLAN 100

IES-5000

VID = 200

Enet2

VID = 100

Enet1

IES-708



ad