Determining Protected Exposures for Noise-Exposed Workers Theresa Y. Schulz, PhD. Lt. Col. USAF (ret.)

Determining Protected Exposures for Noise-Exposed Workers Theresa Y. Schulz, PhD. Lt. Col. USAF (ret.). Agenda. Background NRR Fit-testing studies Fitting HPDs Motivation. Background.

marja
Download Presentation

Determining Protected Exposures for Noise-Exposed Workers Theresa Y. Schulz, PhD. Lt. Col. USAF (ret.)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Determining Protected Exposures for Noise-Exposed Workers Theresa Y. Schulz, PhD.Lt. Col. USAF (ret.)

  2. Agenda • Background • NRR • Fit-testing studies • Fitting HPDs • Motivation

  3. Background Noise-induced hearing loss is the most common permanent and preventable occupational injury in the world. World Health Organization

  4. Background • Worker’s Compensation In many countries, excessive noise is the biggest compensable occupational hazard. Cost of NIHL to developed countries ranges from 0.2 to 2% of its GDP. NIHL is on the rise globally. (Source: WHO)

  5. Background • United States Statistics Most common occupational injury in the United States. 22 million US workers are exposed to hazardous noise at work on a daily basis. Approx. 8 million Americans suffer from NIHL. (Source: NIOSH, 2009)

  6. Background In the United States, 76% of noise-exposed workers need no more than 10dB of protection. 90% need no more than 15dB of protection.

  7. Noise Reduction Rating(NRR)

  8. Noise Reduction Rating

  9. Noise Reduction Rating • How much noise is reaching the ear of the worker ? Noise Level =100 dB Noise Reduction Rating =30 dB That is completely unknown … (55 – 104 dB)

  10. 0 dB 0 dB 33 dB EAR #1 EAR #2 EAR #3 How much protection?

  11. Frequency in Hz 1000 2000 3150 4000 6300 8000 250 500 125 90 Max Good Fit NRR = 33dB Max Poor Fit NRR = 0dB 80 70 60 50 Attenuation in dB 40 30 20 10 0 -10 Good Fit vs Bad Fit

  12. Noise Reduction Rating • Noise Reduction Rating • A laboratory estimate of the amount of attenuation achievable by 98% of users when properly fit • A population-based rating ― some users will get more attenuation, some will get less The NRR is only a population estimate, not a predictor of individual attenuation.

  13. Noise Reduction Rating • NVLAP-Accredited Labs San Diego, CA Indianapolis, IN State College, PA

  14. Noise Reduction Rating – Determining an NRR • 10 human subjects tested in a reverberant room • Tested with ears open/occluded at nine frequencies • Each subject tested 3x • NRR calculated to be population average A test subject in the Howard Leight Acoustical Lab, San Diego, CA, accredited by the National Voluntary Laboratory Accreditation Program (NVLAP)

  15. Noise Reduction Rating – in the real world Real-World Attenuation≠ NRR 192 users of a flanged reusable earplug ~ 27 NRR 50 NRR = 27 Multiple-Use Earplug 40 30 20 Attenuation in dB 10 0 -10 From Kevin Michael, PhD and Cindy Bloyer “Hearing Protector Attenuation Measurement on the End-User”

  16. Noise Reduction Rating • De-Rating Methods OSHA NRR ÷ 2 (feasibility of engineering controls) NIOSH Earmuffs NRR – 25% Formable Earplugs NRR – 50% All Other Earplugs NRR – 70% CSA Class A up to 100 B up to 95 C up to 90 Fit Test

  17. Noise Reduction Rating • Noise Reduction Rating • The EPA recently made an announcement about a proposed change to the Noise Reduction Rating [NRR] • This is the first change in hearing protector regulation in nearly 30 years

  18. Noise Reduction Rating • Three New Labels

  19. Noise Reduction Rating • The New System: A Range • Represents a range of expected protection • Uses a new ANSI-standard (S12.6-2008) lab testing to generate the attenuation ratings • New NRR will provide an indication of how much attenuation minimally-trained users[the lower number] versus highly-motivated trained users [the higher number] can be expectedto achieve • For some hearing protectors, the spread of this range may be quite significant

  20. Noise Reduction Rating • Current vs. Proposed NRR

  21. Noise Reduction Rating • Current vs. Proposed NRR

  22. Noise Reduction Rating 20th % Proficient Users 80th % Minimally-trained Current NRR Label Mock-up of New Label

  23. Noise Reduction Rating • How to Apply the New Label Two-number range displays the estimated protection achievable by minimally-trained users [80%] versus proficient users [20%]. A wider range indicates greater variability in the fit of that HPD. Smaller ranges indicate more consistency of fit. For example, earmuffs will usually have a tighter fitting range than earplugs, and may have a smaller NRR range. 80% 20%

  24. Noise Reduction Rating • Will OSHA 29 CFR 1910.95 change? • OSHA has not announced any proposed changes to the Occupational Noise Standard • OSHA will presumably respond to the revised NRR label by issuing a field directive or technical memorandum, informing its compliance officers how to deal with the new two-number NRR range

  25. Noise Reduction Rating • Will the new rating methods favor earplugs or earmuffs? • While a well-fit foam earplug generally has greater attenuation than most earmuffs, earmuffs are inherently easier to fit for most users • There is less variability in the fit of earmuffs • Overall range of attenuation for earmuffs will usually be tighter and often higher, than earplugs • Workers should be offered a choice of earplugs, bands and earmuffs that meet the requirements of the work environment

  26. Noise Reduction Rating • Earplug Fit Testing • Provides an accurate,real-world picture of hearing protector effectiveness. • Identify if hearing protection users are: • Receiving optimal protection • Require additional training • Need to try a different earplug style

  27. Earplug Fit-testing • As a problem solver: • Derating Schemes • One-on-One Training • HPD Selection • NRR Change

  28. Field Verification – Fit-Testing Real-Ear Attenuation at Threshold (R.E.A.T.) Loudness Balance (Real-Ear Attenuation Above Threshold) Microphone in Real-Ear (M.I.R.E.) In-Ear Dosimetry

  29. Ear plug fit-testing methods

  30. Reducing Costs + Claims OSHA Alliance: Best Practice Bulletin www.hearingconservation.org Additional Information www.howardleight.com

  31. Earplug fit-testing as a Problem Solver Reducing Costs + Claims • Training tool for noise-exposed workers • Train-the-trainer tool • Follow-up on significant threshold shifts in hearing • Documentation of HPD adequacy • Assessment of overall HCP effectiveness • Match HPD to worker’s specific noise level • Selection of appropriate HPDs for new hires • Benefits per Best Practices Bulletin (OSHA Alliance)

  32. Review of some fit-testing studies

  33. Noise Reduction Rating – in the real world Real user attenuation <0 to 38 dB Real-World Attenuation≠ NRR 192 users of a flanged reusable earplug ~ 27 NRR 50 NRR = 27 Multiple-Use Earplug 40 Retraining and refitting resulted in an average 14 dB improvement for this group 30 Attenuation in dB 20 10 0 -10 From Kevin Michael, PhD and Cindy Bloyer “Hearing Protector Attenuation Measurement on the End-User”

  34. Fit-testing Studies Published NRR

  35. Fit-testing Studies Personal Factors Gender Age Years in Noise Ear Canal Size Familiarity Model of Earplug Program Factors # Group Trainings # Personal Trainings

  36. REDUCING COSTS / CLAIMS Fit-testing Studies Published NRR Trying a second earplug often improves attenuation

  37. Self-Efficacy Pilot Study • “How well can users predict their attenuation after a short fit-testing training session?”

  38. Pilot Study Pilot study • Subjects: 17 construction workers with varied HPD experience levels • Equipment: VeriPRO earplug fit-test system • HPD: Volunteers • Process: 2-4 Quick Check fits where employee sees feedback of exact PAR • Subjects

  39. Pilot Study • Data show improved PARs! • Results • Initial RE=19 LE=22 • Final RE=29 LE=27 • Average improvement 7.5 dB

  40. Pre and Post-Test Pilot Study • How would you rate your ability to fit your earplugs? • 1 2 3 4 5 • Don’t know how I do OK Expert • Pre- and Post-Test

  41. Pilot Study Pre and Post-Test Don't know how Expert Not good Not good Expert I do OK I do OK Pretty good Pretty good I do OK Pretty good Expert Fitter Post-Test Ability Initial Ability

  42. Pre and Post-Test Pilot Study • “How much noise do you think your earplugs block?” • Self-Efficacy • 76% (13 of 17) judged attenuation as HIGHER post-test

  43. Pre and Post-Test Pilot Study • Are you better able to assess the effectiveness of your earplugs after VeriPRO fit-testing? • 1 2 3 4 5 • No Maybe No change Improved Yes • Post-Test 64% (11 of 17) rated their abilityHIGHER post-test

  44. Pre and Post-Test Pilot Study • “How well can users predict their attenuation after a short fit-testing training session?"

  45. Pre and Post-Test Pilot Study 20 18 16 14 12 Number of Ears (Each subject estimated atten. for each ear) 10 8 6 4 2 0 Within 5 dB category +/- 7.5 dB (one Category off) +/- 12.5 dB (2 categories off) • Ability to Predict Noise Reduction

  46. Risk Management

  47. Risk Management • Indicators for Hearing Loss: • Standard Threshold Shift • Temporary Threshold Shift • Recordable Hearing Loss • Dosimetry • Labeled NRR (derated?) • In-ear Dosimetry • Personal Attenuation Level (PAR)