1 / 26

PARAID: The Gear-Shifting Power-Aware RAID

PARAID: The Gear-Shifting Power-Aware RAID. Charles Weddle, Mathew Oldham, An-I Andy Wang – Florida State University Peter Reiher – University of California, Los Angeles Geoff Kuenning – Harvey Mudd College. Motivation. Energy costs are rising An increasing concern for servers

maren
Download Presentation

PARAID: The Gear-Shifting Power-Aware RAID

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PARAID:The Gear-ShiftingPower-Aware RAID Charles Weddle, Mathew Oldham, An-I Andy Wang – Florida State University Peter Reiher – University of California, Los Angeles Geoff Kuenning – Harvey Mudd College

  2. Motivation • Energy costs are rising • An increasing concern for servers • No longer limited to laptops • Energy consumption of disk drives • 24% of the power usage in web servers • 27% of electricity cost for data centers • Root to other issues, e.g. server room cooling • Is it possible to reduce energy consumption without degrading performance? The Power Aware RAID – www.cs.fsu.edu/~weddle/

  3. Challenges • Energy • Not enough opportunities to spin down RAIDs • Performance • Essential for peak loads • Reliability • Server-class drives are not designed for frequent power switching The Power Aware RAID – www.cs.fsu.edu/~weddle/

  4. Challenges • Existing Work • Most trade performance for energy savings directly. • e.g. vary speed of disks • Most are simulated results The Power Aware RAID – www.cs.fsu.edu/~weddle/

  5. Observations • Over provisioning of resources • RAID is configured for peak performance • RAID keeps all drives spinning for light loads • Unused storage capacity • Over-provision of storage capacity • Unused storage can be traded for energy savings • Fluctuating load • Cyclic fluctuation of loads • Infrequent on-off power transitions can be effective The Power Aware RAID – www.cs.fsu.edu/~weddle/

  6. Power-Aware RAID • Skewed striping for energy savings • Preserving peak performance • Maintaining reliability • Evaluation • Conclusion • Questions The Power Aware RAID – www.cs.fsu.edu/~weddle/

  7. disk 1 disk 2 disk 3 disk 4 disk 5 Soft-State Block Replication RAID Layout gear 1 gear 2 Skewed Striping for Energy Saving • Use over-provisioned spare storage • Can use fewer disks for light loads The Power Aware RAID – www.cs.fsu.edu/~weddle/

  8. disk 1 disk 2 disk 3 disk 4 disk 5 Soft-State Block Replication RAID Layout gear 1 gear 2 Skewed Striping for Energy Saving • Operate in gear 1 • Disks 4 and 5 are powered off The Power Aware RAID – www.cs.fsu.edu/~weddle/

  9. Skewed Striping for Energy Saving • Approximate the workload • Gear shift into most appropriate gear • Minimize the opportunity lost to save power Conventional RAID PARAID Energy ( Powered On Disks ) workload Workload ( Disk Parallelism ) The Power Aware RAID – www.cs.fsu.edu/~weddle/

  10. load utilization threshold gear shift time Skewed Striping for Energy Saving • Adapt to cyclic fluctuating workload • Gear shift when gear utilization threshold is met The Power Aware RAID – www.cs.fsu.edu/~weddle/

  11. Preserving Peak Performance • Operate in the highest gear • When the system demands peak performance • Maximize parallelism within each gear • Load is balanced on each gear • Uniform striping pattern within each gear • Delay block replication until gear shifts • Capture block writes The Power Aware RAID – www.cs.fsu.edu/~weddle/

  12. Maintaining Reliability • Distributed parity (RAID-5) • Tolerate single-disk failures • Used in soft state • Drives have a limited number of power cycles • Form bi-modal distribution of busy/idle drives • Rotate drives with more power cycles • Ration number of power cycles The Power Aware RAID – www.cs.fsu.edu/~weddle/

  13. role exchange Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 Disk 6 busy disks power cycled disks idle disks Gear 1 Gear 2 Gear 3 Maintaining Reliability • Busy disk stay powered on, idle disks stay powered off • Outside disks are role exchanged with middle disks The Power Aware RAID – www.cs.fsu.edu/~weddle/

  14. PARAID User Administration User Space Linux kernel File System PARAID Monitor PARAID Disk Manager PARAID Reliability Manager RAID PARAID Block Handler Software RAID Disk Device Driver PARAID Implementation • Implemented in Linux 2.6.5 • ≈ 3500 lines of code The Power Aware RAID – www.cs.fsu.edu/~weddle/

  15. PARAID Evaluation • Questions to answer • Can energy consumption be reduced? • Can performance be maintained? • Other questions to answer • Do the power measurements reflect workload as expected? The Power Aware RAID – www.cs.fsu.edu/~weddle/

  16. client RAID USB cable P4 2.8 Ghz, 1 GB RAM 160 GB 7200 RPM SATA RAID crossover cable RAID multimeter RAID server power measurement probes Xeon 2.8 Ghz, 2 GB RAM 36.7 GB 10k RPM SCSI RAID 12v & 5v power lines BOOT SCSI cable power supply PARAID Evaluation • Measurement framework The Power Aware RAID – www.cs.fsu.edu/~weddle/

  17. PARAID Evaluation • FSU web trace workload • Obtained from Florida State University CS web servers - two months of traces • September 19 - 21, 2004, 17,000 requests • Captured web server trace files and a snapshot of the file system • No Worries, file names and content was encrypted The Power Aware RAID – www.cs.fsu.edu/~weddle/

  18. Energy Savings 256x 32x 128x 64x The Power Aware RAID – www.cs.fsu.edu/~weddle/

  19. Disk Utilization 256x 128x 32x 64x The Power Aware RAID – www.cs.fsu.edu/~weddle/

  20. Performance – Peak Hour Latency The Power Aware RAID – www.cs.fsu.edu/~weddle/

  21. Performance – Peak Hour Total Completion Time The Power Aware RAID – www.cs.fsu.edu/~weddle/

  22. Postmark Benchmark • Postmark benchmark • Popular synthetic benchmark • Stresses peak read/write performance of storage device The Power Aware RAID – www.cs.fsu.edu/~weddle/

  23. Conclusion • Energy efficiency and performance can be achieved simultaneously • Work in progress • Understand PARAID under a wider range of workloads. • Explore gear-centric parity schemes • Optimize gear selection and gear shifting The Power Aware RAID – www.cs.fsu.edu/~weddle/

  24. Questions PARAID: The Gear-Shifting Power-Aware RAID • For more information • www.cs.fsu.edu/~weddle/ • Contact • Charles Weddle – weddle@cs.fsu.edu The Power Aware RAID – www.cs.fsu.edu/~weddle/

  25. Postmark Benchmark- Total Completion Time The Power Aware RAID – www.cs.fsu.edu/~weddle/

  26. Postmark BenchmarkPower – 20k Files, 100k Transactions Start in Low Gear Start in High Gear The Power Aware RAID – www.cs.fsu.edu/~weddle/