1 / 33

Ian Bell National Instruments

One Controller - Any Bus Connecting Programmable Automation Controllers ,Measurements, Sensors, Networks and PLCs. Ian Bell National Instruments. Agenda. Industrial Communications Overview Why Connect a PAC to Industrial Networks and PLCs? 3 Methods to Connect to Any PLC or Device

mandy
Download Presentation

Ian Bell National Instruments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. One Controller - Any Bus Connecting Programmable Automation Controllers ,Measurements, Sensors, Networks and PLCs Ian Bell National Instruments

  2. Agenda • Industrial Communications Overview • Why Connect a PAC to Industrial Networks and PLCs? • 3 Methods to Connect to Any PLC or Device • Basic Analogue and Digital I/O • Industrial Network Communication • OPC

  3. Industrial Communications Overview • Common Industrial Networks • DeviceNet • PROFIBUS • Modbus TCP • Modbus Serial • CANopen • FOUNDATION fieldbus • Interbus • CC-Link • LonWorks • HART • PROFINET • Ethernet/IP Industrial communications connect industrial devices such as PLCs, sensors and actuators

  4. Software Capabilities PC PLC Ruggedness and Reliability PAC Architecture • Ruggedness and reliability of PLC • Software capabilities of PC • Modular and diverse I/O PAC

  5. Why Connect PACs to Industrial Networks and PLCs? • High-speed analogue measurements • High-resolution analogue measurements • Advanced analysis (digital filtering, frequency analysis) • Custom hardware performance with FPGA technology • High-speed closed-loop control • FPGA-based processing and analysis • Custom Sensors/Measurements

  6. Industrial Communications Basic I/O Analogue/Digital OPC 3 Methods to Connect to Any PLC PACs PLCs

  7. Basic I/OCheap, Easy, Fast and Effective • Available on every platform • Analog and digital I/O options • PLC users can easily integrate analogue and digital I/O into their code • Allows PACs to act as intelligent devices

  8. Basic I/O • Advantages • Fast, deterministic, little or no software overhead • Considerations • Doesn’t scale well • Point-to-point wiring (parallel) • Can’t communicate lots of data

  9. ExampleAutomated Filling of Aerosol Cans • Existing PLC system was being used to automate the filling of aerosol cans • PLC did not have the capability to do high-speed analogue for pressure measurements • NI CompactRIO PAC was used for high-speed pressure measurements on 8 channels (2 k per channel) • CompactRIO and PLC were integrated using digital I/O

  10. Industrial Communications Basic I/O Analogue/Digital OPC 3 Methods to Connect to Any PLC PACs PLCs

  11. Methods for Industrial Communications Plug-In Interfaces Gateways over Ethernet, Serial Ethernet/Serial Performance/Determinism Versatility

  12. Plug-In Interfaces Plug-In Communication Boards • CAN and CANopen • DeviceNet • FOUNDATION fieldbus • Serial (RS232, RS422, RS485) • Third-party PROFIBUS (Comsoft) • Support for PXI, PCI, PCMCIA, and CompactRIO

  13. Plug-In Interfaces Plug-In Communication Boards • Advantages • Direct, deterministic communication with the processor • Timing and synchronisation with other I/O (DAQ) • High-level API support for LabVIEW and other programming languages • Considerations • Many smaller buses and protocols are not supported • Many only available on PC and PXI (real-time supported)

  14. Example : PROFIBUS • PROFIBUS master/slave for PXI and PCI • More than 2 million nodes • Popular in Europe and Asia • Recommended: Comsoft DF PROFI II interfaces

  15. cRIO-PBMaster/Slave and cRIO-PBSlave • cRIO PB Master/Slave module • Supports operation as DP Master or DP Slave • Ships with configuration tool configurator II for DP Master configuration • Ships with GSD file to configure any DP Master system • cRIO PB Slave module • Supports operation as DP Slave • Ships with GSD file to configure any DP Master system

  16. Ethernet-based Industrial Protocols • Modbus TCP/IP • Ethernet/IP • EtherCAT • Profinet

  17. Why Ethernet: Protocols • Modbus TCP/IP • Modbus • EtherNet/IP • DeviceNet • CanOPEN • EtherCAT • PROFIBUS • PROFInet Traditional Industrial Protocols Ethernet Physical Layer

  18. Modbus TCP/IP Overview • First industrial protocol on Ethernet (introduced 1999) • Based on Modbus developed by Modicon in 1979 • Widely adopted and open Ethernet standard • Advantages • Uses standard Ethernet (hardware and TCP/IP transport layer) • Open and relatively simple • Disadvantages • Not a hard real-time protocol • Does not deliver determinism

  19. Ethernet-based Industrial Protocols • Modbus TCP/IP • Ethernet/IP • EtherCAT • Profinet

  20. EtherNet/IP Overview • Dominant bus for Rockwell Automation • Managed by Open Device Vendors Association (ODVA) • Extends DeviceNET concepts to Ethernet • Advantages • Uses Ethernet transport layer (TCP and UDP) • Disadvantages • Can overload networks with UDP messages if not correctly configured, recommend managed switches with IGMP snooping

  21. Ethernet/IP Terminology

  22. Communication from NI PAC to ControlLogix and ComapctLogix PLCs Ethernet/IP Uses explicit messaging Available for download from NI Labs

  23. Gateways over Ethernet, Serial Third-Party Gateways • Wide variety of communication buses and protocols supported • Ethernet or serial-based • Perfect for non-PXI, PCI, and PCMCIA systems • PROFIBUS • DeviceNet • EthernetIP Ethernet • ControlNet

  24. ExampleAdding Vision for Food Processing Optimisation • Needed NI Compact Vision System to calculate the mass/volume of the food item coming through on the conveyor belt • Ethernet/IP connectivity was a requirement EthernetIP Modbus TCP

  25. Industrial Communications Basic I/O Analogue/Digital OPC 3 Methods to Connect LabVIEW to Any PLC NI PACs PLCs

  26. What Is OPC? Windows PC • Universal language for reading and writing data • OPC Client: Read and write to OPC • OPC Server: Translates between OPC and device-specific protocols English

  27. OPC Client Windows PC Allen-Bradley OPC Server Ethernet/IP OPC Client Siemens OPC Server PROFINET Mitsubishi OPC Server CCLink OPC Driver Device-Specific OPC Server PLCs OPC Client

  28. NI OPC Servers for Third-Party PLCs • OPC support for more than 100 PLCs • Connects with LabVIEW DSC OPC client • Evaluation version included with DSC • Servers included for: • Allen-Bradley • AutomationDirect • Cutler-Hammer • GE • Hilscher • Modbus • Omron • Philips • Siemens • Toshiba • WAGO • Yaskawa • Yokogawa • …and more! • ni.com/opc

  29. OPC • Advantages • Most universal • Least device-dependent • Ideal for HMI and SCADA applications • Considerations • Slower, not deterministic, single-point only • Can require PC-based OPC servers • Not for safety or critical communications

  30. ABCO Adds LabVIEW to PLC System “The ease by which NI can speak to the Allen-Bradley hardware saved me valuable time on this delivery-critical job.” -Arif Bustani, electrical engineer ABCO • ABS brake testing system • PXI for high-speed encoder measurements • Added to existing Allen-Bradley PLC assembly line • OPC used for communication between PXI and Allen-Bradley PLCs

  31. Summary • PACs add flexibility to connect to anything • Use PACs to add any measurements to existing system • 3 Methods to Connect PAC to Any PLC: • Basic Analogue and Digital I/O • Native Industrial Communications • OPC

  32. Online Resources ni.com/comm ni.com/pac ni.com/labs www.modbus.org – Modbus TCP/IP www.odva.org – Ethernet/IP www.ethercat.org – EtherCAT www.profibus.com/pn - PROFINET