Palomar: Cosmic Web Imager

Palomar: Cosmic Web Imager. Who are CWI? Khanh Bui (Structure design) Daphne Chang (Opto-mechanical lead, GRA) Matt Matuszewski (Grating, articulation unit, GRA) Chris Martin (PI) Anna Moore (System Lead) Patrick Morrissey (Detector) Shahin Rahman (Software, GRA) What is CWI?

mandel
Download Presentation

Palomar: Cosmic Web Imager

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Palomar: Cosmic Web Imager Who are CWI? • Khanh Bui (Structure design) • Daphne Chang (Opto-mechanical lead, GRA) • Matt Matuszewski (Grating, articulation unit, GRA) • Chris Martin (PI) • Anna Moore (System Lead) • Patrick Morrissey (Detector) • Shahin Rahman (Software, GRA) What is CWI? • Optical spectrograph for 200” Hale telescope designed specifically for high resolution spectroscopy of low-surface-brightness extended emission with exquisite sky background subtraction • Based on slicer-IFU, 50” FoV, R~5000 Science goal: • Science goal is to directly detect faint cosmic web and circum-galactic medium emission at high redshifts • First light late 2008 CWI shown mounted to the Cassegrain station of the 200” Hale telescope, without enclosure

  2. Palomar: Cosmic Web Imager The camera and dewar assembly must rotate about the center of the grating Collimator IFU VPH grating Camera and dewar Side view/zenith pointing

  3. Infrared Imaging Spectrograph(IRIS) Concept Design • James Larkin PI (UCLA) • Anna Moore co-PI (Caltech) • First light instrument for TMT (2016?) • ~1 year CODR study with review in Feb 2009 • ~450k study, 1/3rd to COO • 0.8-2.5mm, imager and IFU R<4000 • Imager: FoV 10” goal • IFU(lenslet): 4/9 mas/pixel; 2” FoV • IFU(slicer): 22/50 mas/pixel • Spectrograph offers high strehl lenslet and high efficiency slicer • Large part of CODR is to combine lenslet and slicer optics efficiently

  4. 2.25m 4.25m IRIS Envelope Dimensions • The generic instrument envelope is a 2m dia. cylinder extending 3.75m axially from the interface plane • A “snout” portion protrudes 0.5m into NFIRAOS • Maximum total instrument length = 4.25m • The instrument centre of mass is required to lie on axis, 2.25m from the interface plane SNOUT 0.5m INTERFACE PLANE ROTATOR BEARING e.g. ROLLIX 02-1415-00 C of M (5T)