UNIFORMITY STUDY OF INO ICAL’S RESISTIVE PLATE CHAMBER. BY HARIKRISHNAN.A INO DHEP. Introduction. Scintillator is a material which emits light(scintillations) when an ionization radiation falls on it. Plastic scintillator are used.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'UNIFORMITY STUDY OF INO ICAL’S RESISTIVE PLATE CHAMBER ' - macaulay-peck


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

Introduction
Introduction

  • Scintillator is a material which emits light(scintillations) when an ionization radiation falls on it.

  • Plastic scintillator are used.

  • PMT(Photo Multiplier Tube)- A device which converts light into electric current.

  • Light guides are used to carry light from scintillator to PMT

  • Discriminator – An electronic circuit which converts analog signal to a digital pulse.


Uniformity study of ino ical s resistive plate chamber

Calculation Of Efficiency

Delay is added(15ns)

2-fold

ref1

Discriminator 1

ref2

Discriminator 2

3 -fold

Test

Discriminator 3

Efficiency= (3-fold/2-fold)*100


Uniformity study of ino ical s resistive plate chamber

  • Delay: One of the pulse is delayed to decrease time jitter in the coincidence pulse.

  • The threshold for both the reference paddle is set to -25 mV and the test paddle is set as -20 mV


Uniformity study of ino ical s resistive plate chamber

Calculation of Operating Point

2-fold

Delay is added (15 ns)

Ref 1

Ref 2

3 -fold

Delay is added (20 ns)

L Test

3 -fold

Delay is added (30 ns)

U Test

Threshold for all the paddles were set as -25 mV




Zonal efficiency of rpc
Zonal Efficiency Of RPC

  • RPC is placed between two scintillators and will find the efficiency.

  • Our paddles have the area 10cm*10cm.

Paddle 1

14 cm

RPC

14 cm

Paddle 2


Uniformity study of ino ical s resistive plate chamber

5

4

3

2

1

6 5 4 3 2 1 0

As shown in the figure above, in order to calculate the efficiency, we consider the hits in x strips-0 1 2 3 4 and y strips-0 1 2 3 4


Schematic diagram
Schematic Diagram

Discriminator 1

2 fold

Paddle1

INO

DAQ

SYSTEM

RPC

Paddle 2

Discriminator 2

Efficiency= (3fold/2fold)*100



Acknowledgement
Acknowledgement

  • Dr. B.Satynarayana

  • Mr.Sumanta Pal

  • Mr.RavindraShinde

  • Sudheshna Das Gupta

  • S.S Chavan,Vishal