Save presentation, open in PowerPoint, and View “Notes Page” to see slide notes. Origo PhaseID System. No cell phones No work delays due to lack of cellular coverage Use on any voltage Very portable (only 3 lbs) Lowest cost solution available.

Download Presentation

Save presentation, open in PowerPoint, and View “Notes Page” to see slide notes

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Save presentation, open in PowerPoint, and

View “Notes Page” to see slide notes


Origo PhaseID System

  • No cell phones

  • No work delays due to lack of cellular coverage

  • Use on any voltage

  • Very portable (only 3 lbs)

  • Lowest cost solution available


A GPS timing signal is used to simultaneously measure phase at a reference location and at a field location.

The phase attribute at the reference location is known.

By comparing the reference and field phase measurements, the field phase attribute can be determined.

Principal of Operation


Synchronous Motor Connected to Phase A


Synchronous Motors Connected to Phases A, B and C


Snapshot of Synchronous Motors at Same Instant of Time


Phase Measurement Comparisons

  • The reference phase base station can be connected to any convenient wall socket of any phase.

  • Each GPS second, the wall socket phase is measured and stored in a PC file.

  • When touched to any energized line, the field probe measures the unknown phase at the next GPS second and encodes it into a 9-digit sequence.

  • Base and field measurements can be compared at any convenient time and manner by simply entering the 9-digit sequence into the PC.


Available in Handheld or Lineman


Handheld on Transmission Lines

  • 345KV

  • No extendo stick required.

  • Determine all 3 phases with a single measurement.


Handheld on Overhead Lines

69KV

12.5KV


Handheld in Cabinets

12.5KV Bushing

12.5KV test Point


Handheld in Substations

69KV Buss

12.5KV Buss


Handheld on Single Phase Line


Handheld with Netbook PC & Aircard


Convert a 20 Minute Extendo Stick Phasing Task on High Overhead Lines into a 20 Second Task using the Handheld

69KV


Lineman Field Probe

Substation Buss

12.5KV Bushing


Lineman Field Probe

Elbow Test Point

Secondary Conductor


Lineman Secondary Adapter (Optional)


Non-Real-Time phase attribute determination.

Write down the phase sequences and enter them into the base station later.

Call your dispatcher, or any other utility personnel, and give them the 9-digit sequence. They will enter it into their PC and tell you the phase attribute.

Real-Time phase attribute determination if Internet access available.

Automatically records the phase sequence in a measurement file.

Provides GPS location.

Accepts user notes.

Real-Time Satellite communication link available soon.

Available in Manual or Datalogger

Manual Version

Datalogger Version


Base Station Software


Tagging Reference Phase

  • Tagging reference phase is one of the most important concepts of phase identification.

  • Tagging reference phase simply refers to what phase attribute you wish to call each 3-phase conductor.

  • There is no universal “Phase A”. Phases A, B, and C are simply the phase attributes the utility wishes to tag or assign to each of the 3-phase conductors.

  • Once assigned, all conductors of the same phase are tagged according to this chosen tagging reference phase.


Open and Save Configuration Files


Typical Configuration Files


Configuration Setup


Entering Phase Sequences


Secondary Phase Attribute


Primary and Secondary Connection Phase Attributes


Field PC Software


User Inputs


GPS Position


Batch Convert

  • All measurement sequences can be converted to phase attribute with a single click.

  • First, copy the base station daily reference file into the field PC data directory.

  • Next, click on the third icon to the right of the measurement sequence window (red-to-green icon).

  • This action converts all measurement sequences to phase attributes and changes all red dots to green dots.


Three Phase Vertical Lines


Three Phase Horizontal Lines


Remote Base Stations


Lineman Field Probe Soft Case


Lineman Field Probe Hard Case


Base Station


Base Station Antenna


PhaseID USA Customers

(That we know of)

Origo also has customers in Australia, Canada, India, Jamaica, New Zealand, and Taiwan.


Bottom Line

When you are tasked with collecting thousands of attributes to phase identify your entire utility, no other system available is as fast and convenient as the Origo PhaseID System