modine 93 separated combustion condensing unit
Download
Skip this Video
Download Presentation
Modine 93% Separated Combustion Condensing Unit

Loading in 2 Seconds...

play fullscreen
1 / 12

Modine 93% Separated Combustion Condensing Unit - PowerPoint PPT Presentation


  • 74 Views
  • Uploaded on

Modine 93% Separated Combustion Condensing Unit. Modine’s Breakthrough Solution to Commercial Heating. The Next Leap Forward. Question: What is Modine’s breakthrough solution to the issues of commercial heating? Answer: Modine’s NEW Effinity 93 with Conservicore™ Technology

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Modine 93% Separated Combustion Condensing Unit' - lucius


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
modine 93 separated combustion condensing unit
Modine 93% Separated Combustion Condensing Unit

Modine’s Breakthrough Solution to Commercial Heating

the next leap forward
The Next Leap Forward
  • Question: What is Modine’s breakthrough solution to the issues of commercial heating?
  • Answer: Modine’s NEW Effinity 93 with Conservicore™ Technology
    • PTC-Series 93% Thermal Efficient Condensing Gas-Fired Unit Heater

Timing

  • Literature & Pricing Currently Available
  • Full Production September 2009
effinity 93 design features
Effinity 93 Design Features

Unit Components

Power

Exhauster

Bent Tube Primary

Heat Exchanger

Flue Gas

Exhaust

Fresh Combustion

Air Intake

Condensate

Drain

Propeller Fan

& Motor

AL29-4C Stainless Steel

Round Tube Plate Fin

Secondary Heat Exchanger

Gas Manifold,

Orifices & Burners

slide4

Effinity 93 Design Features

The Heart and Soul…

  • Secondary Heat Exchanger Made With AL29-4C Stainless Steel Material
  • Most Robust Material Available to Withstand Acidic Condensate

Condensate Production

  • Approx. 1+ Gallons/hr for Small Units
  • Approx. 2+ Gallons/hr for Large Units
  • Slightly Acidic – Like Soda (Pop)
  • Need to Drain Both Unit & Vent System
effinity 93 design features1
Effinity 93 Design Features
  • Separated Combustion
    • Protects Heat Exchangers & Components from High Humidity & Chemical Corrosives
    • Reduces Greenhouse Heat Loss by 2%
  • Propeller Fans
  • PVC Power Exhauster Wheel & Vent Pipe
    • Flue Temperatures Only Around 125º F
  • Factory Installed External Junction Box Standard
    • Disconnect Switch
    • Convenience Outlet
    • Terminal Board
    • Indicator Lights
ptc series condensing unit heaters
PTC-Series Condensing Unit Heaters

PTC Outputs Closely Match Outputs of Standard Efficiency Unitsfor Ease of Comparison When Sizing & Selecting New Construction, Expansion or Replacement Jobs

  • PTC135 output equates to 80% 150MBH output
  • PTC155 output equates to 80% 175MBH output
  • PTC180 output equates to 80% 200MBH output
  • PTC215 output equates to 80% 250MBH output
  • PTC260 output equates to 80% 300MBH output
  • PTC310 output equates to 80% 350MBH output
effinity 93 application flexibility
Effinity 93 Application Flexibility

Options & Accessories

  • Stainless Steel Primary Heat Exchangers
    • Recommended for Greenhouse Applications Due to Humidity
  • Finger-Proof (OSHA) Fan Guards
  • Step-Down Transformers
  • Concentric Vent Kits
  • Condensate Pumps & Neutralizer Kits
  • 2-Point Suspension Kits
  • Deflector Hoods & Vertical Deflector Blades
  • Thermostats
  • Energy Saver Kit
    • Ceiling T-Stat Energizes Fan Without Burner as Ceiling Temps Rises
effinity 93 benefits
Effinity 93 Benefits

What This Means to the Building OwnerGrower

  • 17% Fuel Savings Over Standard Power Vented & Separated Combustion Units
  • 40% Fuel Savings Over Natural Draft Gravity Vented Units!!!
  • May Qualify for Local Rebate & Tax Incentive Programs
  • Separated Combustion Advantages
    • Reduced Air Changes & Heating Loads
    • Longer Lasting Heat Exchangers, Burners & Controls
  • PVC Vent Pipe & Power Exhauster Wheels
    • Lower Installed Costs & Replacement Costs vs. Metal
  • All Other Advantages of Gas-Fired Unit Heaters Apply
    • Warm Air Circulation, Vented Flue Products, Redundancy, Heat De-Stratification, Zone Control, Low Installed Costs, etc.
  • Direct-Fired Efficiencies Without Direct-Fired Disadvantages
    • Water Vapor, Ethylene, Required Air Changes
  • Boiler Efficiencies Without Boiler System Disadvantages
    • High Up-Front Costs, Mechanical Rooms, Piping System Complexity, No Redundancy, Lower Water Temperatures
state local efficiency incentives
State & Local Efficiency Incentives

www.dsireusa.org

  • Renewables & Efficiency Incentive Programs
  • Searches by State, Program Type, Technology Type, etc.
    • Helps Offset Costs to Upgrade to High Efficiency Equipment
    • Significantly Reduces Payback Period
    • May Find Incentives for Other Efficiency Upgrades Such as Thermal Blankets, Caulking & Insulation, High Efficiency Motors, Lighting, etc.
for more information
For More Information…

Modine.com\Building HVAC\Greenhouse Heating Solutions

ad