Building. Prof Sarosh Lodi. TOPICS COVERED. Intro. FLEXURAL MEMBERS OF SMRF. General Clear span not less than 4 times effective depth Width/depth ratio not less than 0.3 Width not less than 10 in

lucie
Download Presentation

Building

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Building Prof Sarosh Lodi

  2. TOPICS COVERED • Intro

  3. FLEXURAL MEMBERS OF SMRF • General • Clear span not less than 4 times effective depth • Width/depth ratio not less than 0.3 • Width not less than 10 in • Width not more than width of supporting member plus distance on each side of supporting member equal to ¾ of the depth of flexural member Cont.

  4. FLEXURAL MEMBERS OF SMRF • Longitudinal Reinforcement • Reinforcement ratio not less than 200/fy • Reinforcement ratio not more than 0.025 • Two bars should be continuous in top and bottom • +ve moment strength at joint face should not be less than ½ of –ve moment strength • +ve or –ve moment strength at any section should not be less than ¼ of strength at joint face • Lap allowed only with hoop or spiral reinforcement • Lap splices are not allowed • within joints • a distance of 2d from joint face

  5. FLEXURAL MEMBERS OF SMRF Longitudinal Reinforcement

  6. FLEXURAL MEMBERS OF SMRF • Transverse Reinforcement • Maximum hoop spacing shall not exceed • d/4 • 8 times dia of smallest longitudinal bar • 24 times dia of hoop bar • 12 in • Examples of hoops are Cont.

  7. COLUMNS FOR SMRF • General • Shortest cross-sectional dimension is 12 in. • Ratio of shortest dimension to perpendicular dimension shall not be less than 0.4

  8. COLUMNS FOR SMRF • Reinforcement • Longitudinal reinforcement ratio not less than 0.01 and not more than 0.06 • Concrete cover for transverse reinforcement shall not exceed 4 in. • Spacing of rings (s) shall not exceed • s=¼ of minimum column dimension • s=6 times dia of longitudinal bar • s=4+[(14-hx)/3] 4”< s <6” • Length of column (L) for above ring spacing shall not be less than • depth of column • 1/6 of clear span • 18 in.

  9. COLUMNS FOR SMRF • Reinforcement • Spacing (S1) for the rest of column length is smaller of • 6 times longitudinal bar dia • 6 in. • Example of rings is

  10. COLUMNS FOR SMRF

  11. COLUMNS FOR SMRF

  12. COLUMNS FOR SMRF

  13. COLUMNS FOR SMRF • Joints • Beam longitudinal reinforcement must be extended to the far face of column and anchored • Column dimension parallel to the beam reinforcement not be less than 20 times bar dia • Transverse reinforcement shall be provided in joint

  14. INTERMEDIATE MOMENT RESISTING FRAME • Beams • +ve moment strength at joint face should not be less than 1/3 of –ve moment strength • +ve or –ve moment strength at any section should not be less than 1/5 of strength at joint face • First hoop provided at 2 in. from face of support • Maximum hoop spacing shall not exceed • d/4 • 8 times dia of smallest longitudinal bar • 24 times dia of hoop bar • 12 in

  15. INTERMEDIATE MOMENT RESISTING FRAME • Columns • Hoops provided at spacing (s) over length (L) from both ends • s should be smallest of • 8 times dia of smallest longitudinal bar • 24 times dia of hoop bar • ½ of smallest dimension of frame member • 12 in • L should be largest of • 1/6 of clear span of column • Minimum dimension of column • 18 in

  16. INTERMEDIATE MOMENT RESISTING FRAME • Columns • Hoops provided at spacing (s) over length (L) from both ends • s should be smallest of • 8 times dia of smallest longitudinal bar • 24 times dia of hoop bar • ½ of smallest dimension of frame member • 12 in • L should be largest of • 1/6 of clear span of column • Minimum dimension of column • 18 in