1 / 16

VESPA-22: Microwave Spectrometer for Stratospheric Water Vapor in Polar Regions

VESPA-22 is a microwave spectrometer capable of measuring stratospheric water vapor in Polar regions. It plays a crucial role in studying air mass dynamics, cloud formation, and ozone loss in the stratosphere.

lthrasher
Download Presentation

VESPA-22: Microwave Spectrometer for Stratospheric Water Vapor in Polar Regions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A microwave spectrometer capable of measuring stratospheric water vapour in Polar regions: VESPA-22 G. Mevi1,2, G. Muscari1, P. P. Bertagnolio1, I. Fiorucci1 1Istituto Nazionale di Geofisica e Vulcanologia 2Università Roma Tre

  2. The importanceofpolarstratospheric water vapour • Stratospheric water vapour regulates cloud formation in the upper troposphere and is involved in the surface temperature increasing measured in the last decades. • (Solomon et al., 2010) • It can be used as a tracer to study the air mass dynamics and the exchanges between troposphere and stratosphere (Holton et al., 1995). • It has an important role in the seasonal ozone loss observed in the polar stratosphere.

  3. An indirectmeasurement: the microwavespectroscopy We can obtain information about the vertical concentration profile of the water vapour by measuring its thermal emission. • Benefits: • The transition is between well populated states at typical stratospheric temperature • We can take measurements during both day and night • We can neglect the scattering due to aerosol and atmospheric molecules • We can use low cost components to assembly the instrument

  4. An indirectmeasure: the microwavespectroscopy We can obtain information about the vertical concentration profile of the water vapour by measuring its thermal emission. • Disadvantages: • We need at least 6 hours of integration of our signal to grant a significant • signal to noise ratio • We need an observation site characterized by a dry troposphere to • minimize the signal absorption.

  5. Keyphysicalprinciplesbehind the measurement Radiative transfer Pressurebroadening

  6. The spectrometer VESPA-22 Central frequency: 22.23 GHz Bandwidth: 500 MHz Frequency resolution: 31 kHz (16384 channels) No need for cryogenic cooling Theoretically we can retrieve H2O vertical profile from 30 to 90 km of altitude

  7. The spectrometer VESPA-22 The signal is channelled to the front end electronics by a parabolic mirror The mirror can rotate to receive radiation from different angles. The front end is composed by low noise amplifiers, a noise diode to calibrate the signal and two mixers to shift the signal to lower frequencies. The back end spectrometer converts the signal from the time to the frequency domain.

  8. How to get the stratospheric signal: the balanced beams technique The signal of our interest is very small compared to the tropospheric background signal. In order to observe the stratospheric emission we compare the emission from two different beams at different zenital angles and rescale our measurement by a scaling factor.

  9. Howtoget the stratosphericsignal: the balancedbeamstechnique • By using this technique we remove gain nonlinearities from the spectrum • Tropospheric opacity can change during the measurement. In order to average several hours of data we need a Scaling Factor to normalize the measured spectra • In order to perform this technique we assume a horizontally homogeneous sky

  10. Signalcalibration To calibrate the observedspectrawe use the knownemission of noisediodes. We calibrate the noisediodes by observing the emission from twoblack body sources at knowndifferenttemperatures (~77 K and ~300 K).

  11. From the measured spectrum to the concentration vertical profile • Water vapour vertical profiles can be obtained from our measurements by using the indirect problem theory • We employ an optimal estimation algorithm to retrieve the profile that has • the largest probability of generating the observed spectrum, given the local climatology

  12. The optimalestimationalgorithm • We modify our apriori profile using the spectral information • The Optimal Estimation can be seen as a weighted average of the apriori information • given by local climatology and the new information gathered with the measurement • The matrix A can be used as an estimate of the vertical resolution and • sensibility interval of retrieved profiles

  13. A test measurementcampaign at Campo Imperatore (AQ)

  14. A test measurementcampaign at Campo Imperatore (AQ)

  15. Conclusions and things to do… • Vespa-22 is capable of retrieving vertical stratospheric water vapour profiles from 30 • to 90 km altitude, but signal artifacts can reduce this range. • It can operate automatically, with low level technical assistance and with a temporal • resolution of 2-4 measures/day, depending on weather conditions • We are working on the instrumental setup to minimize signal artifacts • The retrieval algorithm must be improved to reduce the dependency of the 15-30 km • altitude interval to the water vapour concentration in the troposphere. This can be done • using auxiliary measurements as apriori profile • The collected measurements will be studied to better understand the radiative and • dynamical processes that characterize the polar atmosphere.

  16. Thank you for the attention!