An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable

    2. Blow the whistle on plant downtimes Keep the overview of your 24V load feeders. Show the red card to downtimes caused by faults

    3. The situation today

    4. Reasons for selective triggering failure when fault occurs Long load lines Creeping short circuits Line circuit breakers dimensioned too large ? Consequences Plant standstill due to drop in 24 V power Trouble-shooting much more difficult Long standstill times Reason for undesired triggering during operation Excessive current peaks during startup ? Consequence Malfunction, machine/plant switches off The situation today

    5. The solution Fault paths are powered down reliably even under very poor operational conditions. Retension of the 24 V power for all other paths Plant down time is reduced or even avoided. Fast trouble-shooting and fault localization Loads with high startup current peaks power up with current limitation. Malfunction-free device startup

    6. The solution Selectivity and fast error diagnosis of 24 V feeder circuits Four feeder circuits (outputs) per module Each output can be set between 2 and 10 A using potentiometer. Multi-color LED for each output for rapid fault localization Potential-free common signal contact for fault diagnosis Several modules can be connected to a single power supply. Simple and rapid installation using standard mounting rail Additional line protection and gradual equipment commissioning with exchangeable FK2 blade-type fuse

    7. Circuit diagram

    8. Switching characteristic Irated can be adjusted from 2 to 10 A per output circuit. Characteristics per current requirements depend on the output circuit. From 0 A to the set value ( I/ Irated=100%) ? without switching off From set value up to 130% ? switch off after approx. 5 sec Above 130% of set value ? current limiting to 130% for 50 to 100 msec, next switch off Over the set value with simultaneous collapse of the supply voltage below 20V ? immediate switch off

    9. Device features

    10. Ordering data, technical specifications