1 / 16

Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

MODEL. OVERVIEW. OBSERVATION. RESULTS. PROS & CONS. STUDY. CONCLUSION. The empiric elimination of the water vapour influence. Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012.

liuz
Download Presentation

Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION The empiric elimination of the water vapour influence Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012 1Martin Vicar, 2Ladislav Peksa, 2Tomas Gronych, 1Zdenek Krajicek, 1Dominik Prazak, 2Martin Jerab, 1Frantisek Stanek 1 Czech Metrology Institute 2 Charles University in Prague

  2. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE TASK: TO STATE THE UNKNOWN HELIUM FLOW FROM THE LEAK PROCEDURE USED: INDIRECT COMPARISON WITH THE STANDARD LEAK USING THE QUADRUPOLE MASS SPECTROMETER AS A COMPARATOR Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  3. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE TASK: TO STATE THE UNKNOWN HELIUM FLOW FROM THE LEAK PROCEDURE USED: INDIRECT COMPARISON WITH THE STANDARD LEAK USING THE QUADRUPOLE MASS SPECTROMETER AS A COMPARATOR Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012 OR UNKNOWN FLOW 1 KNOWN FLOW 2 QMS PFEIFFER PRISMA QUADRUPOLE MASS SPECTROMETER PUMPING

  4. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION ASSUMPTION 1: P = Q / PUMPING SPEED ASSUMPTION 2: I = SENSITIVITY * P Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012 OR UNKNOWN FLOW 1 KNOWN FLOW 2 QMS PFEIFFER PRISMA QUADRUPOLE MASS SPECTROMETER PUMPING

  5. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION ASSUMPTION 1: P = Q / PUMPING SPEED ASSUMPTION 2: I = SENSITIVITY * P Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012 OR UNKNOWN FLOW 1 KNOWN FLOW 2 QMS PFEIFFER PRISMA QUADRUPOLE MASS SPECTROMETER PUMPING

  6. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE OBSERVED SIGNAL FOR HELIUM – UNEXPECTED UNSTEADY SIGNAL Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  7. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE OBSERVED SIGNALS FOR HELIUM AND WATER Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  8. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE CORRELATION BETWEEN SIGNALS FOR HELIUM AND WATER Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  9. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE CORRELATION BETWEEN SIGNALS FOR HELIUM AND WATER MODEL: Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  10. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE CORRELATION BETWEEN SIGNALS FOR HELIUM AND WATER MODEL: Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  11. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE CORRELATION BETWEEN SIGNALS FOR HELIUM AND WATER MODEL: Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  12. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE CORRELATION BETWEEN SIGNALS FOR HELIUM AND WATER MODEL: Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  13. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION + SIMPLE METHOD + INTERESTING RESULTS + CAN BE USED IF HELIUM SIGNAL DECLINES WHEN WATER SIGNAL RISES – DOES NOT GIVE USEABLE RESULTS FOR CASES WHEN HELUM SIGNAL RISES TOGETHER WTH THE WATER SIGNAL – WE HAVE NOT THE EXACT THEORETHICAL EXPLANATION ABOUT THE INTERACTION MECHANISM AND PLACE Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  14. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THE RELATIVE DECREASING / INCREASING OF THE HELIUM SIGNAL Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  15. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION THERE EXIST DIFFERENT PHENOMENA WHICH SHOULD BE TAKE INTO ACCOUNT. SOLUTIONS CORRECT SIGNAL AS DESCRIBED ABOVE (WHEN POSSIBLE). CLOSE THE SMALL VALVE OF THE CALIBRATED STANDARD LEAK (ENSURES MORE STABLE CONCENTRATIONS OF THE ATMOSPHERIC GASES). USE SPECIAL APPARATUS FOR HELIUM LEAKS COMPARISON. OPEN QUESTIONS DOES EXIST A THEORETICAL BACKGROUND THAT COULD JUSTIFY OUR EMPIRICAL CORRECTION PROCEDURE? Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

  16. MODEL OVERVIEW OBSERVATION RESULTS PROS & CONS STUDY CONCLUSION Thank you for your attention. Martin Vicar mvicar@cmi.cz Martin Vicar ‒ The empiric elimination of the water vapour influence EMRP IND12 workshop, 2012

More Related