PCB Flexure Comparison Testing
This presentation is the property of its rightful owner.
Sponsored Links
1 / 8

PCB Flexure Comparison Testing PowerPoint PPT Presentation


  • 163 Views
  • Uploaded on
  • Presentation posted in: General

PCB Flexure Comparison Testing NMC Standard & NMC-P Soft Terminal Ceramic Chip Capacitor MLCCs.  Ceramic Capacitors www.niccomp.com/ceramic Specification : NMC-P series www.niccomp.com/catalog/nmcp.pdf FREE Samples : www.niccomp.com/samples Technical Support : [email protected]

Download Presentation

PCB Flexure Comparison Testing

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Pcb flexure comparison testing

PCB Flexure Comparison Testing

NMC Standard & NMC-PSoft Terminal Ceramic Chip Capacitor MLCCs

  •  Ceramic Capacitors www.niccomp.com/ceramic

  • Specification:NMC-P series www.niccomp.com/catalog/nmcp.pdf

  • FREE Samples: www.niccomp.com/samples

  • Technical Support: [email protected]


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 PCB Flexure Comparison Testing

NMC standard & NMC-PSoft Terminal Ceramic Chip Capacitor MLCCs

Test PCB

  • PCB Deflection: 1.0 mm, 1.5 mm, 2.0 mm, 3.0 mm, 4.0 mm, 5.0 mm, 6.0 mm, 7.0 mm, 8.0 mm, 9.0 mm, 10.0 mm

  • Test Samples: n= 10 pieces

  • Monitor 1KHz Capacitance Value / Failure Criteria = ∆C of ≥±12.5%

No failures to 10mm deflection

10 out of 10 failures by 7.0mm deflection

Page 2


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 PCB Flexure Comparison Testing

NMC standard & NMC-PSoft Terminal MLCCs

No failures to 10mm deflection

10 out of 10 failures by 4.0mm (1206) & 9.0mm (1210) deflection

Page 3


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 PCB Flexure Comparison Testing

NMC standard & NMC-PSoft Terminal MLCCs

No failures to 10mm deflection

10 out of 10 failures by 5.0mm deflection

Page 4


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 PCB Flexure Comparison Testing

NMC standard & NMC-PSoft Terminal MLCCs

Cross-Sectional Analysis Comparison

After de-mounting from test PCB, performed cross-sectional comparison to allow inspection of internal structure

NMC Series

NMC-P Series

PCB flexure MLCC cracking

Low IR, Short failure mode

  • Summary:

  • All standard terminal (NMC series) samples exhibited failure under PCB flexure testing

  • Failure mode defined as capacitance decrease ≥12.5% and low insulation resistance (IR)

  • Cracking in ceramic microstructure (as shown in above image, left) is cause of the failure

  • None of the NMC-P series (polymer soft terminal) exhibited failure

  • No cracking was observed in NMC-P series (polymer soft terminal)

Page 5


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 Polymer Layer – Open Circuit Function

Example of polymer layer terminal separation (open circuit) for NMC-P Series (Polymer Soft Terminal) under 10mm PCB deflection

PCB Deflection: 1.0 mm, 1.5 mm, 2.0 mm, 3.0 mm, 4.0 mm, 5.0 mm, 6.0 mm, 7.0 mm, 8.0 mm, 9.0 mm, 10.0 mm

Test Samples: n= 10 pieces

Monitor 1KHz Capacitance Value / Failure Criteria = ∆C of ≥±12.5%

DPA of Failed Sample

No failures to 9mm deflection

2 out of 10 failures at 10mm deflection

10 out of 10 failures by 8.0mm deflection

Page 6


Pcb flexure comparison testing

NMC vs. NMC-P in PCB Flexure Testing

 Polymer Layer – Open Circuit Function

Example of polymer layer terminal separation (open mode) for NMC-P Series (Polymer Soft Terminal) under 10mm PCB deflection

Cross-Sectional Analysis

Cross-Sectional Analysis

Magnified view

Polymer layer opened under 10mm PCB deflection

Component is undamaged

PCB flexure Open failure mode

Page 7


Pcb flexure comparison testing

Resources

  •  Specification: NMC-P series www.niccomp.com/catalog/nmcp.pdf

  • Quick Builder, component selection made easy: www.niccomp.com/QB-ceramic

  • FREE Samples: www.niccomp.com/samples

  • NIC Contacts:

    • Sales support: _____________________

    • Technical support: [email protected]

Page 8