Mock-up detector simulation 제 9 회 RENO collaboration meeting. I. S. Jeong*, C. W. Park RENO Collaborators. Contents: 1) MockUp Introduction 2) Structure Summary a. Bridges(Target, Gamma-Catcher) b. Chimney(Short Chimney) c. PMT Holder d. Baffle

Download Presentation

Mock-up detector simulation 제 9 회 RENO collaboration meeting

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Mock up detector simulation 9 reno collaboration meeting

Mock-up detector simulation제9회 RENO collaboration meeting

I. S. Jeong*, C. W. Park

RENO Collaborators


Mock up detector simulation 9 reno collaboration meeting

Contents:

1) MockUp Introduction

2) Structure Summary

a. Bridges(Target, Gamma-Catcher)

b. Chimney(Short Chimney)

c. PMT Holder

d. Baffle

e. Updated Version(Optional)

f. New Positioning

3) Analysis(Quick-Check)


Mockup

MockUp

Definition of MOCK-UP:

In common usage, a mockup is a scale model of a structure or device, usually used

for teaching, demonstration, testing a design, etc. - WIKIPEDIA

Figure 2.

RENO Mock-Up detector

Figure 1.

RENO Main(full-sized) detector


Bridge target

Bridge(Target)

290mm

confirmation

Target Position(Z=-445mm)

G4double tXaxis0 = 216.5

G4double tXaxis1 = 0

G4double tXaxis2 = -216.5

G4double tXaxis3 = -216.5

G4double tXaxis4 = 0

G4double tXaxis5 = 216.5

G4double tYaxis0 = 125

G4double tYaxis1 = 250

G4double tYaxis2 = 125

G4double tYaxis3 = -125

G4double tYaxis4 = -250

G4double tYaxis5 = -125

Unit:mm


Bridge gamma catcher

Bridge(Gamma-Catcher)

Gamma-CatcherPosition

(Z=-850mm)

G4double gXaxis0 = 357.2

G4double gXaxis1 = 0

G4double gXaxis2 = -357.2

G4double gXaxis3 = -357.2

G4double gXaxis4 = 0

G4double gXaxis5 = 357.2

Radius

Radius of buffer tank: 1100mm

G4double gYaxis0 = 206.23

G4double gYaxis1 = 412.5

G4double gYaxis2 = 206.23

G4double gYaxis3 = -206.23

G4double gYaxis4 = -412.5

G4double gYaxis5 = -206.23

Curvature

√Gap

Between bridge & Stainless steel: 5mm

Gamma-Catcher Bridge Length: 490mm → 495mm

Implementation

Thickness of stainless steel:5mm

Height and width


Chimney short chimney

Chimney(Short Chimney)

Middle Chimney

Short Chimney


Pmt holder

Prototype Holder Test

in the Drum

37.1847°

PMT Holder

d:depth

D:Diameter

H:Height

T:Thickness

Realistic Holder

PMT middle holder’s design

confirmation

Holder Parameter


Baffle top bottom

Baffle(Top,Bottom)

Confirmation

Top Baffle

After adjustment

Top & Bottom

Bottom Baffle


Mock up detector simulation 9 reno collaboration meeting

Baffle(Side)

Side Baffle

Side


Mock up detector simulation 9 reno collaboration meeting

Updated Version(Optional)

Baffle – Cont’More Realistic for the Top

CABLE WAY

CABLE WAY

231.5mm

277mm

Updated Baffle(Top)


New positioning for the baffle analysis

New Positioning for the Baffle Analysis

  • Because Baffles is over the buffer region,

    we couldn’t know how it run.

Baffle이 Buffer를 넘어버려 이들의

Effect를 볼 수 없음


Etc viton analysis ready

Etc(Viton Analysis) - ready

SiliconPAD가 없을 경우

Viton에 대한 geometry

SiliconPAD가 있을 경우


P e analysis quick check

P.E. Analysis(Quick-Check)

1) Nothing

2) Only Target Bridge

3) Only Gamma-Catcher Bridge

4) All Bridge

5) Only Holder

6) Only Baffle

7) Holder & Baffle


Bridge analysis

Bridge Analysis

Nothing

Only Gamma-Catcher

All Bridge

Only Target


Holder baffle analysis

Holder & Baffle Analysis

Baffle with Holder

Only Holder

Only Baffle


Offset analysis

Offset Analysis

+ 10mm offset

- 20mm offset


Source calibration ge

Source Calibration( Ge)

68


Summary

Summary

Chimney, Bridge(Target, Gamma-Catcher),

Holder, Baffle, Viton등 축소형 검출기를 위한 MC에

모두 구축되어 있음(cable 제외)

Todo list

MC(for MockUp) Stability Check

Energy, Vertex Calibration using the Source(Co137, Ge68...)


Backup

Backup


Quick comparison

Quick Comparison

Without Bridge

With Bridge


Tyvek

TYVEK

Overlapped noTYVEK(X & Zaxis)

Overlapped TYVEK(X & Zaxis)

Without TYVEK(X-axis)

With TYVEK(X-axis)

Without TYVEK(Z-axis)

With TYVEK(Z-axis)