An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 20080825 Feb 2012 KI 2600 Series Power Meters www.kingfisherfiber.com

  2. Course Contents • General Features -3 • Keypad -4 • Operation -5 • Menu System -11 • Modes of operation -14 Select Display Measurement unit -22 Memory Operation -29 Other Features -31 Instrument care -38

  3. 1./ General Features • Autotest • Calibrated at multiple wavelengths • Industry standard connector adaptors • Large high contrast LCD display • Power - Battery or micro USB • Memory – Internal or USB • Time date stamp • Text ID • Test tone detection 3

  4. 2./ Keypad Backlight Remove Connector Connector Cover On/Off Lanyard holder Store External Power & Computer interface USB port for memory stick Memory, Text ID, Date [F1-F4] [F1-F4] Toggle Centre

  5. 3./ Operation • Select / determine test cord configuration • Fit adaptor • Fit batteries • Turn On • Menu System

  6. 3.1 / Select test cord connector Identify fibre type required for test cord and configuration required. • Supplied with :- SC connector as standard Unlike sources, power meters accept both PC and APC connectors.

  7. To fit / change an adaptor / connector • Locate quick release button on front of instrument at base of connector housing • Lightly push and hold latch button in • Pull out existing adaptor • Release latch button. • Fit new adaptor. Slot to outside

  8. 3.2 / Fit Batteries • Unclip Battery compartment cover at rear of instrument • Note: battery +Ve terminal spring orientation • Instrument time setting holds for approx 7 seconds during change over. • Alkaline battery run time approx 1,000 hours

  9. Battery type configuration • To enable rechargeable batteries to be internally charged this feature must be enabled by means of an 0.1” pitch shorting pin. or Alkaline Battery configurations Instrument supplied in this configuration. Rechargeable Battery configuration

  10. 3.3 / Turn On • 10 minutes auto off • Permanent operation • Low battery indicator To turn On / Off: Push the Green [On/Off] button • To Defeat auto time out. • Press [On/Off] & hold for 3 seconds. • Instrument will beep twice. • ‘Perm’ will display on the upper RHS of the LCD.

  11. 4./ Menu System • Top level Menu Memory Meter

  12. 4.1/ Memory Menu • Return to • Top Level Menu Memory Home Memory Mode Read Memory Select dBm, dBr, Watt

  13. 4.2/ Meter Menu Meter Home Set Ref Meter Mode Hold Return to Top Level Menu In dBr mode, Set 0 dBr Select dBm, dBr, Watt Hold the display

  14. 5./ Modes of Operation • Autotest: • automatically toggles between all wavelengths • Preferred mode for loss testing as testing time is greatly reduced. • Minimises error as meter always displays correct wavelength. • Manual: • Single wavelength operation • Preferred mode for level monitoring. • Test Tone: • Displays incoming modulation frequency • Slow Mode: • Displays power level in the presence of test tone or low level modulation • KITS software: • Under software control

  15. 5.1 / Autotest • When receiving light from a compliant source operating in Autotest mode, the meter will auto toggle between wavelengths. • Power meter receives data which contains wavelength, source serial number and nominal source output power. • If power meter not calibrated at an incoming wavelength it will ignore it but remain in sync with other wavelengths. • If incoming power level too low at a particular wavelength it will ignore it but remain in sync with other wavelengths. Simplest mode for loss testing 15

  16. Autotest Display • When receiving light from a source operating in Autotest mode: • Screen displays up to 3 wavelengths at a time. • Screen toggles if more than 3 wavelengths being received

  17. 5.2 / Manual Mode • To enter Meter mode • Press [F3], Meter

  18. Select Wavelength • To select wavelength • Toggle [-] & [+]. • Note: • Wavelength toggle is not circular • Most meters have the common wavelengths grouped together for speed of access when used in manual mode. E.g. 850, 1300, 1310, 1550, 1625 nm are together

  19. 5.3 / Test Tone • When receiving test tone or low level modulation • Power meter displays modulated frequency and beeps • To measure power in the presence of tone, SlowMode is used. • To defeat Beeping:- • At Turn-On hold [F2].

  20. 5.4/ SlowMode • SlowMode: • Used when it is necessary to measure power in the presence of test tone or low level modulation e.g. low data rate SCADA transmissions. • When active, the meters sample interval is increased. • The symbol ” ” is displayed when active. SCADA: supervisory control and data acquisition • In the presence of Test Tone: • To activate, Press [F4] • To turn Off, Press and hold [F3] (Meter Mode) & then press [F4]. • In normal Mode: • To activate, Press and hold [F3] (Meter Mode) & then press [F4]. • To turn Off, Press and hold [F3] (Meter Mode) & then press [F4].

  21. 5.5 / KITS control • Click results directly into workbook • Standards based & user definable analysis • Data Logging • Memory extract to KITS or CSV file • Familiar Excel™ User Interface • Inbuilt multi language support • Customisable reports Direct Interface to - KITS™ Testing & Reporting softwareInstrument under computer control

  22. 6./ Select Display Measurement unit • Absolute Mode: • Measure actual power level at a particular location in decibels – dBm • Relative Mode: • Measure power level ‘relative’ to a particular location in decibels – dBr • Linear Mode: • Measure power level at a particular location in watts - W • Absolute dBm / Relative dBr mode / Linear W mode

  23. Toggle Absolute/Relative/Linear • Repeated pressing of Meter Mode button [F3] , toggles through Absolute – dBm, Relative - dBr and Linear - W modes.

  24. 6.1 / Set Reference • If not in dBr mode, press [F3], Meter Mode as required to enter dBr mode. • Press and hold [F2] Set Ref for approx 2 seconds. • Meter will beep 4 times and zero

  25. -6.99 dBm 2x 10-2 mW -47.71 dBm 1.67x10-5 mW 0 dBr -40.72 dBr Loss = Send – Receive dB => Loss = (-6.99) – (-47.71) = 40.72 dB

  26. 7./ Memory Operation • Memory clear • Memory store • Memory recall • Dump to USB memory

  27. 7.1/ Memory Clear • To clear Memory: • Press and hold [Toggle Centre] then press [On/Off] • ‘CLr’ will be displayed for a few seconds. • Stored Text ID Tags are not cleared by this procedure. If not in Memory mode, Press [F2] , Memory 2 1

  28. 7.2/ Memory Store • To Store: • Press [],Store • Instrument will beep and Memory increment • Stored Memory location displayed whilst button depressed. • To save to to a specific Memory location: • Toggle [-] & [+] to desired memory. • Press and hold[F2],Memory for 3 seconds. • Instrument will beep once new location is set. • Future Memory saves continue from this location.

  29. 7.3/ Memory Recall • If not in Memory mode, Press [F2] , Memory • To view Memory, press [F4] • To toggle between dBm, dBr and W, press [F3] • For data stored in Autotest mode, ‘auto’ displays • To toggle memory press [-] or [+] • To exit memory mode, press [F1] , Home Toggling stored data metrics

  30. 7.4/ Dump to USB memory • Must be in Memory mode to detect USB memory stick. • To enter Memory Mode: • Press [F2], Memory. • or • Press [F1], Home, then press [F2], Memory. • Insert USB memory stick. • ‘USB’ will show on the LCD • If not in Memory mode, Press [F2] , Memory • Press [] to start Memory dump. • ‘WAIT’ will display whilst USB memory configured. • A buzzer will sound during memory dump. • Do not remove USB stick until ‘USB’ has stopped flashing.

  31. 8./ Other features • Set date/Time • Min-Max Recording • Cable text ID

  32. 8.1/ Set Date-Time • Turn On instrument while holding down [Toggle Centre] • To modify the selected time/date, press [-] or [+] • To select next/last time and date item: • Press [Toggle Centre] or [F3] ,Mode, next item will flash. • To Save & Exit, press [F2] , Memory. • To exit without saving, press [F1] , Home. Date Time setting order is:- Hour -> Minute ->Month -> Date -> Year • Loss of Power. • If batteries are removed for longer than about 20 seconds, Date-Time settings are lost

  33. 8.2/ Min – Max recording • Max/Min display mode: • Maximum & Minimum power meter values are continuously recorded. • Function disabled in Autotest. • To activate / Hide: • Press [-] and [+] simultaneously. • To Reset: • Change wavelength. • Set Reference. • Power Off/On.

  34. 8.3/ Cable/ Text ID tag • Text ID: • Used in conjunction with Memory save to identify a location or a cable. • Max 20 individual text ID tags • Format is 4 Alphanumeric letters, followed by 3 digits • The last 3 digits Auto increment. • e.g. CLEM 062, CLEM 063 etc etc.

  35. Create Text / Location ID • If not in meter mode, press [F3], Meter. • Press [Toggle centre] , then [F4] • A new ID tag AAAA 001 will display, the active character will flash. • Toggle [-] and [+] to select an alphanumeric character. • Press [Toggle centre] to select. • To Save & Exit, press [F2] , Memory. • To exit without saving, press [F1] , Home. 2 1

  36. Using Text / Location IDs • If not in meter mode, press [F3], Meter. • Press [Toggle centre] , Text/Location ID tag will flash. • Press [-] or [+] to select. • To Save & Exit, press [F2] , Memory. • To exit without saving, press [F1] , Home.

  37. Delete Text / Location ID • If not in meter mode, press [F3], Meter. • Press [Toggle centre] • Press [-] or [+] to select stored ID to be deleted. • Press [F3], then [F4] , • Location ID replaced by a row of flashing dots/dashes. • To confirm deletion, press F2, Memory. • To exit without changing press F1, Home.

  38. 9./ Instrument Care • Keep the instrument in a carry case during storage and transport • • Use only high quality batteries. • • For prolonged storage remove batteries. • • The instrument is resistant to normal dust and moisture, however it is not waterproof. • If moisture gets into the instrument, remove batteries & dry it out carefully before using it again. • • Where possible, keep instrument away from strong sunlight. • • Clean the instrument case using Iso-Propyl-Alcohol (IPA) or other non solvent cleaning agents. • • DO NOT use Acetone or other active solvents.