C hecking the quality of diagnostic tools
This presentation is the property of its rightful owner.
Sponsored Links
1 / 16

C hecking the quality of diagnostic tools PowerPoint PPT Presentation


  • 42 Views
  • Uploaded on
  • Presentation posted in: General

C hecking the quality of diagnostic tools. Zrinjka Mišak Referral Centre for Paediatric Gastroenteorology and Nutrition Children’s Hospital Zagreb Zagreb, Croatia. ESPGHAN guidelines for the diagnosis of coeliac disease in children and adolescents. An evidence-based approach

Download Presentation

C hecking the quality of diagnostic tools

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


C hecking the quality of diagnostic tools

Checking the quality of diagnostic tools

Zrinjka Mišak

Referral Centre for Paediatric Gastroenteorology and Nutrition

Children’s Hospital Zagreb

Zagreb, Croatia


C hecking the quality of diagnostic tools

ESPGHAN guidelines for the diagnosis of coeliac disease in children and adolescents.

An evidence-based approach

Husby S, Koletzko S, Korponay-Szabó IR, Mearin ML, Phillips A, Shamir R, Troncone R, Giersiepen K, Branski D, Catassi C, Lelgeman M, Mäki M, Ribes-Koninckx C, Ventura A, Zimmer KP. (The ESPGHAN Working Group on Coeliac Disease Diagnosis)

J Pediatr Gastroenterol Nutr, 2012


The importance of serology

The importance of serology

ESPGHAN guidelines

Recommendation 8.3.1:

  • Histological assessment may be omitted in symptomatic cases, who have high IgA anti-TG2 levels (10 x above uppernormal limit), verified by EMA positivity, and are HLA DQ2 and/or DQ8heterodimer positive.


Anti tg2

Anti-TG2

  • Numerical values obtained with different kits - differ

  • The valuesdepend on:

    • the source (human or animal)

    • quality and exposure of the antigen

    • calibrators

    • buffers

    • measuring methods

    • cut-off values

    • calculation mode of the results


Anti tg21

Anti-TG2

  • Despite of differences, many commercial anti-TG2 tests have equally high sensitivity and specificity

  • Inter-laboratory variability also exists

  • There may be considerable batch to batch variability within commercial anti-TG2 assays which needs to be monitored by the use of independent quality control material


Anti tg22

Anti-TG2

ESPGHAN guidelines:

Evidence statement

  • The numeric values obtained with different test kits in anti-TG2 or anti-DGPantibody measurements cannot be directly compared as they may differ intheir measurement principles, calibrators and calculation mode of results.


C hecking the quality of diagnostic tools

ESPGHAN guidelines

Recommendation 7.4.4:

  • Anti-TG2 and anti-DGP laboratory test results should be reported asnumeric values together with specification of the immunoglobulin classmeasured, the manufacturer, the cut-off value defined for the specific test kit,and, (if available) the level of ’high’ antibody values.

  • It is not sufficient to stateonly positivity or negativity. Information on the source of the antigen (natural,recombinant, human, non-human) should be provided for in-house methods.


C hecking the quality of diagnostic tools

EMA

  • in experienced hands has the highest specificity and positive likelihood ratio for CD among currently available serology tools.

  • It is more likely that CD is present if the EMA is positive than if another CD antibody result is positive.

  • EMA tests require microscopicalevaluation and may be subject to interobservervariability

  • It islabourintensive, and the substrates (monkey oesophagus, umbilicus) are limited


C hecking the quality of diagnostic tools

ESPGHAN guidelines

Recommendation 7.4.5:

  • (↑↑) Reports on EMA results should contain

    • the specification of the investigatedimmunoglobulin class,

    • the interpretation of the result (positive or negative),

    • the cut-off dilution and

    • the specification of the substrate tissue.

    • It is also useful tohave the information on the highest dilution still positive.


The role of the laboratory

The role of the laboratory

ESPGHAN guidelines:

Statement:

  • The expertise of the laboratory and the selection of the test kit influence the accuracy of CD antibody tests.


C hecking the quality of diagnostic tools

ESPGHAN guidelines

Recommendation 7.4.3:

  • (↑↑) Laboratories providing CD antibody test results for diagnostic use shouldcontinuously participate in quality control programme at national or Europeanlevel.


Our experience children s hospital zagreb croatia

Our experience – Children’s Hospital Zagreb, Croatia

  • Intra-laboratory control

    • Control samples in every set of tests

  • Inter-laboratory control

    • Together with other University Hospital in Zagreb and some German medical centres


Biopsy

Biopsy

ESPGHAN guidelines

Recommendation 8.3.9:

  • (↑) It is recommended that the pathology report includes:

    • description of the orientation

    • evaluation of villi (normal or degree of atrophy)

    • evaluation of crypts

    • villous/crypt ratio

    • number of IELs

  • Grading according to Marsh-Oberhuber is recommended.


Our experience children s hospital zagreb croatia1

Our experience – Children’s Hospital Zagreb, Croatia

  • Before - one pathologist at the School of Medicine

    • Courses, seminars...

  • Now – more pathologists at university centers and general Hospitals


Suggestions

Suggestions

Serology

  • Sharing the information on how to validate the test and to do intra-laboratory control

  • Set up local inter-laboratory controls

  • Network to do inter-laboratory control

  • Comparative evaluation

  • when comparing between data sets with different units or widely different means - coefficient of variation should be used

    (Cv = Standard Deviation / Mean)

    Biopsy

  • Sharing the knowledge on how to interpret biopsies


C hecking the quality of diagnostic tools

Thank

you!


  • Login