Gas-Chromatography

Gas chromatography LZ-GC-A100: Column Oven Temperature Range Ambient temperature: 7 u00b0C to 400 u00b0C (in 1 u00b0C increments) For more information, visit www.Labozon.com.

Download Presentation

Gas-Chromatography

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gas Chromatography LZ-GC- A100 www.labozon.com | info@labozon.com Overview Gas Chromatography LZ-GC-A100 is adesktop and tabletop device that can separate and identify different compounds in a mixture. It uses a Flame Ionization Detector (FID) and can handle temperatures up to 450°C with a maximum heating rate of 40°C per minute. It can also accommodate different types of detectors, such as TCD, ECD, FPD, and NPD, and allows for both packed and capillary column installation at the

  2. Specifications : Sample injector and Evaporation chamber Sample Introduction system Ambient Temperature range temperature +7℃ ~ 400℃ (in 1℃ increment) Temperature accuracy ± 0.02℃ 400℃ to 50℃ in 8-10 min at 25℃ ambient Cooling period Column Oven Temperature setting 0.1℃~40℃/min (in 1℃ increment) 7 ramps in total (10 ramps available with control workstation) Program ramps 284 x 280 x 241 mm (Inside) 340 x 345 x 281 mm ( Outside) Dimensions

  3. Detection Limit ≤3×10-12g/s (C16) Base test result ≤3×10-12g/s (C16) Flame Ionization Detector (FID) Drift ≤6×10-13A/30min Noise ≤5×10-14A Linearity range ≥106 ≥5000mV, mL/mg (C16) Sensitivity Baseline noise ≤20µV Thermal Conductivity Detector (TCD) Drift ≤60µV/h Linearity range ≥104 ≤8×10-13g/s(P) ; ≤8×10-11g/s(S) Detection limit Flame Photometric Detector (FPD) Drift ≤2×10-11A/30min Baseline noise ≤5×10-12A ≤5×10-12g/s (N) (Azobenzene) ≤5×10-13g/s(P) (Malathion) Nitrogen-Phosphorus Detector (NPD) Detection limit Dimensions 340 x 345 x 281 mm Packing Dimensions 780 x 840 x 920 mm Weight 70 kg

  4. Features : 1. Combination of Gas chromatograph and Flame Ionization Detector (FID) 2. Designed for controlling and monitoring the instrument via computer 3. TCD, FID, FPD, and NPD as optional detector, with 3 detectors installation at a time 4. Features multistage programmed temperature control function 5. Large oven capacity to hold 3 chromatographic columns 6. Chromatography workstation software, for easy and convenient data processing Supports self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.) Function 7. Intuitive display timing program, detector status, measurement range, current setting, etc 8. Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control 9. Superior thermal performance with programmed temperature setting of 40℃ 10. Highly-efficient, stable and reliable with easy and convenient operation Applications : Gas Chromatography is used for the separation of compounds in complex mixtures based on the polarity of compound across food industries, pharmaceuticals, dairy, environmental analysis etc. microbiology, biotechnology,

  5. Accessories : FID detector Chromatography workstation software Labozon Scientific Inc. 100 Pearl St, Hartford, CT 06103, United States. | Phone:+1 860-944-7786 Email: info@labozon.com Website: www.labozon.com