First results from silicon and diamond sensors

First results from silicon and diamond sensors. K. Afanasiev 1 , I. Emeliantchik 1 , E. Kouznetsova 2 , W. Lohmann 2 , W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen. CVD diamond :. Radiation resistant ( up to 10 MGy) Fast (charge collection time ~ 10 ps)

kuri
Download Presentation

First results from silicon and diamond sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. First results from silicon and diamond sensors K. Afanasiev1, I. Emeliantchik1, E. Kouznetsova2, W. Lohmann2, W. Lange2 1NC PHEP, Minsk 2DESY Zeuthen

  2. CVD diamond : • Radiation resistant ( up to 10 MGy) • Fast (charge collection time ~ 10 ps) • Low dielectric constant => Low capacitance but • Low signal : < ½ signal from silicon Charge collection distance dc:

  3. Si - Diamond comparison

  4. Sr/cosmics ADC PA delay discr & Gate discr Test Set Up Si/diamond 5 mm SC. 2 lead (for cosmics only) SC. 1

  5. Test Set Up

  6. PA : VV 50-3 (charge sensitive) ADC : CAEN V265 12 bit Electronics calibration Cf 1 pF gen 50 Cw Cv = g·Cf (diamond sensor connected ) ENC = 700 e

  7. 90Sr Si/diamond (300 mm) 5 mm SC. 2 & SC. 1 Sr Sr Y Y E, MeV Sr source + triggering system

  8. Emip = 1.25 MeV dE/dx = 3.56 MeV/cm R = 0.3 cm Emip = 1.5 MeV dE/dx = 5.57 MeV/cm R = 0.2 cm Sr source + triggering system => ~mip - signal

  9. Signals from 90Sr – silicon : Si (mip)

  10. Sr ADC delay in PA diamond discr gate Signals from 90Sr – diamond : • Selftriggering: Diamond (whole b-spectra) Diamond (noise)

  11. Problems and further steps : • Noise level is not optimal for signal/noise separation • Possible solutions : • Noise optimization of the existing preamplifier or • Switch to Amptek A250: • New trigger scintillator matching the size of the sensor Expected noise ≤ 350 e

  12. Further steps : New diamond samples : • Fraunhofer Institute (Freiburg) : • (12 x 12 mm) • 300 and 200 mm • Different surface treatments • Prokhorov Institute (Moscow) (Dubna group)