1 / 22

What have I been up to?

What have I been up to?. RAT analysis Will show the results at RPC Detector Performance Group meeting 27 Jan. Workshop at Rice: “CSC System Overview” ALCT fuse blowing is a concern Figured out a way to Power-on the system cleanly Wrote first drafts for CSC Quarterly Report

kort
Download Presentation

What have I been up to?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What have I been up to? • RAT analysis • Will show the results at RPC Detector Performance Group meeting 27 Jan. • Workshop at Rice: “CSC System Overview” • ALCT fuse blowing is a concern • Figured out a way to Power-on the system cleanly • Wrote first drafts for CSC Quarterly Report • Electronics Commissioning  now in F. Borcherding’s hands… • Shift structure  now in R. Breedon’s hands… G. Rakness (UCLA)

  2. RE+1/2 pad-bit mapping G. Rakness (UCLA)

  3. Recall ALCT key wiregroup vs. CLCT key ½-strip: heuristic RPC pad-bit mapping for ME+1/3 1 0 3 2 4 5 6 7 ALCT key wiregroup () 8 9 10 11 CLCT key ½-strip () ME+1/3 data G. Rakness (UCLA)

  4. ALCT key wiregroup vs. CLCT key ½-strip for ME+1/2: RPC pad bit = 0 ALCT key wiregroup () CLCT key ½-strip () ME+1/2  odd chamber number SAME Local-(x,y) position as ME+1/3 ME+1/2  even chamber number REVERSED Local-(x,y) position as ME+1/3 G. Rakness (UCLA)

  5. ALCT key wiregroup vs. CLCT key ½-strip for ME+1/2: RPC pad bit = 1 ALCT key wiregroup () CLCT key ½-strip () ME+1/2  odd chamber number SAME Local-(x,y) position as ME+1/3 ME+1/2  even chamber number REVERSED Local-(x,y) position as ME+1/3 G. Rakness (UCLA)

  6. ALCT key wiregroup vs. CLCT key ½-strip for ME+1/2: RPC pad bit = 2 ALCT key wiregroup () CLCT key ½-strip () ME+1/2  odd chamber number SAME Local-(x,y) position as ME+1/3 ME+1/2  even chamber number REVERSED Local-(x,y) position as ME+1/3 G. Rakness (UCLA)

  7. ALCT key wiregroup vs. CLCT key ½-strip for ME+1/2: RPC pad bit = 3 ALCT key wiregroup () CLCT key ½-strip () ME+1/2  odd chamber number SAME Local-(x,y) position as ME+1/3 ME+1/2  even chamber number REVERSED Local-(x,y) position as ME+1/3 G. Rakness (UCLA)

  8. “Theoretical” RPC Pad Bit Mapping Compared with CSC data G. Rakness (UCLA)

  9. LA A B LB C LC Conventions of RPC rolls and strips corresponding to CSC ALCT wiregroups and CLCT ½-strips y • Local-y (r, [, ]): • RPC: 3 “Rolls” each covering a length LN • CSC: ALCT key wiregroup • Local-x: • RPC: 32 strips per Roll; 1 pad bit = “OR” of 8 strips • CSC: CLCT key ½-strip x Increasing ALCT key wiregroup Increasing CLCT key ½-strip G. Rakness (UCLA)

  10. LA A B LB C LC “Theoretical” Assumptions • Assume no offsets and equal active areas of CSC and RPC—this would be “Ideal” • ALCT wiregroup 0  Bottom of Roll C • ALCT wiregroup 32 (ME1/3) or 64 (ME1/2)  Top of Roll A • CLCT ½-strip 0  Left edge of Rolls A, B, and C • CLCT ½-strip 128 (ME1/3) or 160 (ME1/2)  Right edge of Rolls A, B, and C Increasing ALCT key wiregroup Increasing CLCT key ½-strip (LN numbers from C. Carrillo [U. de Los Andes]) G. Rakness (UCLA)

  11. RE+1/2: Data vs. geometrical expectations The red lines are the boundaries expected from RE+1/2 Roll geometry assuming equal and overlapping active areas…  The data are approximately consistent with these assumptions G. Rakness (UCLA)

  12. RE+1/2: Data vs. Geometrical Expectations The data are approximately consistent with expectations G. Rakness (UCLA)

  13. RE+1/3: Data vs. geometrical expectations The red lines are the boundaries expected from RE+1/3 Roll geometry assuming equal and overlapping active areas…  The data are not consistent with this assumption  Where are the active areas of the RPC endcap? G. Rakness (UCLA)

  14. RE+1/3: Data vs. Geometrical Expectations Where are the active areas of the RPC endcap? G. Rakness (UCLA)

  15. Summary of RPC data in RAT • Good correlation seen between CSC trigger primitive position and RPC Endcap data • See reversal of even RE+1/2 chambers, as expected • RE+1/3 pad-bit maps well onto CSC active area • Modification of RE+1/3 pad bit mapping in the RPC Link Board will be needed to optimize “ghostbusting” for CSC trigger primitives • Given that RPC roll geometry cannot be corrected with the Link Board, I believe this mapping will have to go into TMB… • Recall: RPC Endcap data are late relative to the CSC trigger primitive • RPC Link Board data needs to be faster in order to be useful for CSC trigger primitives  Link Board thinks they have only 3.5 – 4.5 bx latency… (M. Konecki, Warsaw) • How much of this is coming from cable lengths? • D. Loveless said that there are several meters of excess cable length... G. Rakness (UCLA)

  16. ALCT Blowing Fuses Discovery in Feb. 2008: Loading the incorrect firmware type to ALCT can cause an on-chamber fuse to blow • April 2008: the software to load ALCT firmware was upgraded to include hard-coded checks on: • xml parameters (slot, chamber label, ALCT type) • hardware (readback of PROM ID codes, crate controller ID) • N.B. Still need to include “verify” when programming ALCT PROM to ensure the program is correct before it is loaded to the FPGA … Even with this fix, fuses were continuing to blow at a (low) rate… But… recall that this is not the first occurrence of blowing fuses… G. Rakness (UCLA)

  17. Preliminary Discussion on Blowing Fuses  19 November 2007  Present: F. Borcherding, M. Ignatenko, F. Geurts, S. Golyach, G. Rakness Goal: To make a plan of action regarding blowing fuses on board ALCT Recall: ~no fuses blew in all FAST site tests… (Note: summary of discussion at workshop January 2009: no solid ideas of what could be causing fuses to blow…) G. Rakness (UCLA)

  18. How close to the blowing current are we? Fuses on both ALCT and LVDB are 5A • Currents drawn by ALCT (values measured at 904 with 28 Aug 2008 firmware version): • 3.3V  3.3A for FPGA communication(2/3 of fuse rating) • 1.8V  1.9A for FPGA core(40% of fuse rating) • 5.5V_1  2.6/0.1 A with AFEBs ON/OFF • 5.5V_2  2.6/0.1 A withAFEBs ON/OFF • At UCLA, it was pointed out to me that… • These numbers are uncomfortably close  inductance effects could easily push over the threshold • It would be interesting to measure these values at large trigger rates • In the FPGA, an input line being changed to an output line (e.g., resulting from a single corrupted bit) could cause this problem… G. Rakness (UCLA)

  19. What is the ideal power-up scenario? • Recall, we have already been developing a power-up procedure during 2008… • Is it complete? • A controlled power up of the “Final Destination” (i.e., Chamber or Peripheral Crate) would require the following steps. First, for the Peripheral Crate… • Voltage Control Board power ON • Voltage Control Board disable output power to the Final Destination • Power source to the Final Destination ON • Voltage Control Board enable output power to the Final Destination • Next, perform steps 1 – 4 for the Chamber… G. Rakness (UCLA)

  20. CSC LV Control Distribution Power Source Voltage Distribution Final Destination Maraton Chamber LVDB CRB Peripheral Crate Maraton LVMB DMB Atlas PCMB Voltage Control Boards Voltage Control Power Source • Current power-up sequence features: • Atlas power supply + PCMB control independence allows the Peripheral Crate to be powered up in the “Ideal” way… • However, we currently power on ALL Maraton channels when powering on the peripheral crate Step 3 is achieved before 1 and 2 for the Chambers… • Furthermore, since the default state of the LVMB is to enable output voltage when the DMB is powered on, steps 1 and 2 are coupled to 4 for the Chambers… •  “Ideal” power-up condition is NOT achieved for the Chambers G. Rakness (UCLA)

  21. Modification of Power-On Procedures Items in red are updates to the procedure from October 2008 in order to power-up the chambers in the “ideal” way… • DCS “Disable peripheral crate monitoring” • Stops VME reads while powering on components (step 2) • Avoid “colliding packets” between csc-dcs-pc[1,2] and csc-pc[1,2] (steps 3-6) • Set digital and analog lines to 0V • This “turns off” power to the chamber • Power on Maratons • Turn on Peripheral crates with PCMB (as in the “normal” power-up sequence... causes the following to happen serially to each peripheral crate • enable power to 1.5V… pause 150ms • For (TMB/DMB pair 1 to 9) • enable TMB/DMB… pause 150ms [TMB LEDs on (not flashing), DMB lower two LEDs on] • additional pause 150ms • enable Crate Controller (VCC)… pause 100ms [VCC “FPGA ready” LED on] • enable MPC/CCB [TMB's and DMB's FPGAs loaded] • “Check crate controllers” • reads VCC FPGA version and checks that the VCC can communicate with CCB • Peripheral Crate Initialization • CCB hard reset to load FPGA’s to Peripheral Crate electronics • Turn off Chambers from LVDB (through DMB) • Set digital and analog lines to 7.5V • This enables voltage to the chambers • Finish the Crate Power-up Init • Power ON chambers, CCB hard reset, configure TTCrq, put MPC in serializer mode • TTCci configure • Sends “broadcast 0” to all TTCrq for final configuration (to correctly decode BGo commands) • “Check Crates Configuration” • Read and check configuration of TMB, ALCT, DMB, CFEB, MPC, CCB • DCS “Enable peripheral crate monitoring” G. Rakness (UCLA)

  22. To do • Test power-up procedure on one trigger sector in ME+1 • Measure voltage vs. time with oscilloscope at power-on • Measure current vs. time (?) • Attempt to measure time-of-flight in beam-halo or CRAFT data… G. Rakness (UCLA)