EXPANSION DE LA GENERACION Y TRANSMISIÓN EN EL SADI

EXPANSION DE LA GENERACION Y TRANSMISIÓN EN EL SADI. UBICACIÓN GEOGRÁFICA DE FUTURA GENERACION TÉRMICA Y NUCLEAR. BDIER. LOPEZ (280 MW). V. OBLIGADO (800 MW). ATUCHA II (720 MW). BELGRANO II (800 MW). GENELBA TV (80 MW). BARRAGÁN (800 MW). TOTAL: 3470 MW.

Download Presentation

EXPANSION DE LA GENERACION Y TRANSMISIÓN EN EL SADI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EXPANSION DE LA GENERACION Y TRANSMISIÓN EN EL SADI

  2. UBICACIÓN GEOGRÁFICA DE FUTURA GENERACION TÉRMICA Y NUCLEAR BDIER. LOPEZ (280 MW) V. OBLIGADO (800 MW) ATUCHA II (720 MW) BELGRANO II (800 MW) GENELBA TV (80 MW) BARRAGÁN (800 MW) TOTAL: 3470 MW

  3. SITUACION DE POTENCIAS DE CORTOCIRCUITO - AREA GBA ACTUAL Referencias 500 kV 220 kV ATUC V. LÍA SITUACION ACTUAL NO HAY SUPERACION DE POT. DE CORTOCIRCUITO CAMP BELG 1 MTH TAL PNUE RODR MOR POTENCIAS DE CORTOCIRCUITO < 25000 MVA POTENCIAS DE CORTOCIRCUITO < 25000 MVA MAL COST PMOR ZAP CAS HUDS TRAD BROW BARRAG BOSQ LPLA EZEI ABAS

  4. AÑO 2013 - INGRESO DE ATUCHA II ATUC AÑO 2013 INGRESO ATUCHA II NO HAY SUPERACION DE POT. DE CORTOCIRCUITO ATUCHA II V. LÍA CAMP BELG 1 MTH TAL PNUE RODR MOR POTENCIAS DE CORTOCIRCUITO < 25000 MVA POTENCIAS DE CORTOCIRCUITO < 25000 MVA MAL COST RMEJ PMOR MITR ZAP CAS HUDS TRAD BROW BARRAG BOSQ LPLA EZEI ABAS

  5. AÑO 2015 INGRESO DE BELGRANO II Y GENELBA TV ATUCHA I Y II ATUC AÑO 2015 INGRESO BELGRANO II Y GENELBA TV SUPERACION DE POT. DE CORTOCIRCUITO V. LÍA CAMP BELG 1 Y 2 BELGRANO II SMITH MTH PUENTEO DE 2 LÍNEAS INGRESANTES A ET EZEIZA EDI TAL PNUE RODR MOR POTENCIAS DE CORTOCIRCUITO < 25000 MVA POTENCIAS DE CORTOCIRCUITO > 25000 MVA MAL COST RMEJ PMOR MITR ZAP CAS HUDS TRAD BROW BARRAG BOSQ GENELBA TV 80 MW LPLA EZEI ABAS

  6. Ampliaciones de la red de Alta Tensión en el corto plazo Aprobadas por la Secretaría de Energía (Resolución 700/2011) como parte del PLAN FEDERAL DE TRANSPORTE EN ALTA TENSION

  7. 1° ETAPA AMPLIACIONES RED DE 500 KV LÍNEA RINCÓN-RESISTENCIA CAMMESA 270 Km LÍNEA RÍO CORONDA-ROSARIO OESTE CAPACITORES SERIE EN LÍNEA RINCÓN – MERCEDES LINEA RÍO DIAMANTE-CHARLONE– GBA CON CAP. SERIE CAPACITORES SERIE EN LÍNEA RESISTENCIA – ROMANG 70 Km 500 Km CAPACITORES SERIES EN INTERCONEXIÓN COMAHUE-CUYO 400 Km CAPACITORES SERIES EN LÍNEA PTO. MADRYN -CHOELE LÍNEA BAHÍA BLANCA-VIVORATÁ

  8. 1° ETAPA OTRAS AMPLIACIONES ADICIONALES CAMMESA • E.T. ROSARIO OESTE: • BANCO DE TRANSFORMADORES 500/220 KV – 800 MVA + FASE RESERVA • E.T. RAMALLO: • TRANSFORMADOR TRIFÁSICO 500/220 KV – 300 MVA • E.T. EZEIZA • BANCO DE TRANSFORMADORES 500/220 KV – 800 MVA • SECCIONADORES PARA PUENTEO DE LINEAS

  9. 2° ETAPA AMPLIACIONES RED DE 500 KV CAMMESA 270 Km • ACOMETIDAS AL AREA GBA A DEFINIR 70 Km 400 Km 500 Km LÍNEA VIVORATÁ – ABASTO CON CAP. SERIE 350 Km 400 Km 350 Km 350 Km LÍNEA MADRYN-CHOELE CHOEL CON CAP. SERIE LÍNEA CHOELE -BAHÍA BLANCA CON CAP. SERIE

  10. Cobos • Saenz Peña • San Isidro • Mercedes • 2009 • Arroyo Cabral • Los Reyunos • Sta Cruz Norte • GRANDES CENTRALES QUE REQUIEREN RED DE TRANSMISION • Monte Quemado • Formosa • La Rioja 3)DESDE AREA CUYO Y COMAHUE POR CENTRALES LOS BLANCOS, CORDON DEL PLATA, CHIHUIDO Y OTRAS 2) DESDE AREA NEA POR CENTRALES BINACIONALES GARABI-RONCADOR (SOBRE EL RIO URUGUAY) 1) DESDE AREA PATAGÓNICA POR CENTRALES CONDOR CLIFT, LA BARRANCOSA, RIO TURBIO Y EÓLICAS

  11. POSIBLES AMPLIACIONES DE MEDIANO PLAZO Región Patagonia

  12. PREVISIÓN INGRESO GENERACIÓN EÓLICA EN REGIONES DEL SADI 50 MW 134 MW 2110 MW 737 MW 1060 MW Status a Agosto 2012 Total~5300 MW 2230 1170 MW

  13. GENERACION TOTAL POSIBLE EOLICAS POTENCIA A INSTALAR (SEGÚN SOLICITUDES RECIBIDAS): 2200 MW Sta. Cruz Norte CONDOR CLIFF + LA BARRANCOSA: 1740 MW POTENCIA POSIBLE A INSTALAR TOTAL ~ 4200 MW Barran. Cóndor Cliff Sta. Cruz Sur RIO TURBIO: 240 MW La Esperanza Río Turbio

  14. GENERACION EÓLICA PEQUEÑA: UNA LÍNEA DE 500 KV ADICIONAL PARALELA A LA EXISTENTE • Red Actual • Ampliaciones: • 2700 Km LÍNEAS 500 KV • CAPACITORES SERIE • SVC 6500 MW Mar del Plata SVC SVC 2200 MW • SIN INGRESO IMPORTANTE DE GENERACION EÓLICA. • UNA LÍNEA DE 500 KV PARALELA A LA EXISTENTE (Desde Pto. Madryn hasta Abasto es parte del Plan Federal de Transporte en AT) EOLICA (pequeña) 400 MW Sta. Cruz Norte CONDOR CLIFF + LA BARRANCOSA: 1740 MW Río Santa Cruz Esperanza • Río Gallegos RIO TURBIO: 240 MW

  15. GENERACION EÓLICA PEQUEÑA: UNA LÍNEA DE 500 KV ADICIONAL POR EL OESTE • Red Actual • Ampliaciones: • 3000 Km LÍNEAS 500 KV • CAPACITORES SERIE • SVC 6500 MW Mar del Plata SVC SVC 2200 MW EOLICA (pequeña) 400 MW • SIN INGRESO IMPORTANTE DE GENERACION EÓLICA. • UNA LÍNEA DE 500 KV PARALELA A LA EXISTENTE (Desde Choele hasta Abasto es parte del Plan Federal de Transporte en AT) Sta. Cruz Norte CONDOR CLIFF + LA BARRANCOSA: 1740 MW Río Santa Cruz • Esperanza • Río Gallegos RIO TURBIO: 240 MW

  16. GENERACION EÓLICA MEDIA: UNA LÍNEA DE CORRIENTE CONTINUA • Red Actual • Ampliaciones 500 KV: • 1200 Km LÍNEA • CAPACITORES SERIE • SVC • Ampliaciones DC: • 2200 Km LÍNEA (bipolo) • CAPACIDAD: 3000 MW 9000 MW 3000 MW 1000 MW EOLICA (media) 1500 MW • CON INGRESO MEDIO DE GENERACION EÓLICA. • 1 LÍNEA DE DC Sta. Cruz Norte 1000 MW Río Santa Cruz • Esperanza • Río Gallegos

  17. GENERACION EÓLICA ALTA: UNA LÍNEA DE 500 KV ALTERNA + 1 LINEA CORRIENTE CONTINUA • Red Actual • Ampliaciones: • 2700 Km LÍNEAS 500 KV • CAPACITORES SERIE • SVC • Ampliaciones DC: • 2200 Km LÍNEA (bipolo) • CAPACIDAD: 3000 MW 9500 MW Mar del Plata SVC SVC 2200 MW 3000 MW EOLICA (alta) 3000 MW • CON INGRESO ALTO DE GENERACION EÓLICA. • UNA LÍNEA DE 500 KV PARALELA A LA EXISTENTE (Desde Choele hasta Abasto es parte del Plan Federal de Transporte en AT) • 1 LÍNEA DE DC Sta. Cruz Norte Río Santa Cruz Esperanza • Río Gallegos

  18. IDEMAS ANTERIOR CON LINEA DE 500 KV DE ALTERNA POR EL OESTE • Red Actual • Ampliaciones: • 3000 Km LÍNEAS 500 KV • CAPACITORES SERIE • SVC • Ampliaciones DC: • 2200 Km LÍNEA (bipolo) • CAPACIDAD: 3000 MW 9500 MW Mar del Plata SVC SVC EOLICA (alta) 3000 MW • CON INGRESO ALTO DE GENERACION EÓLICA. • UNA LÍNEA DE 500 KV PARALELA A LA EXISTENTE (Desde Choele hasta Abasto es parte del Plan Federal de Transporte en AT) • 1 LÍNEA DE DC 3000 MW Sta. Cruz Norte Río Santa Cruz • Esperanza • Río Gallegos

  19. HAY VARIAS OPCIONES DE LOCALIZACION ESTACIONES CONVERSORAS Mar del Plata SVC? LOCALIZACION EN GASTRE E.T. GASTRE E.T. GASTRE LOCALIZACION EN SANTA CRUZ NORTE

  20. POSIBLES AMPLIACIONES DE LARGO PLAZO Región NEA

  21. AREA NEA – CENTRALES HIDROELECTRICAS GARABI Y PANAMBI • CENTRALES HIDROELÉCTRICAS GARABI Y PANAMBI • POTENCIA INSTALADA TOTAL ~ 2400 MW • LA GENERACION TOTAL DE AMBAS CENTRALES DEBERÁ PODER INYECTARSE TANTO AL SISTEMA ARG. COMO BRASILEÑO CENTRAL HIDROELÉCTRICA YACYRETÁ: 3000 MW ACTUALES CONVERSORAS GARABI: 2000 MW Paraná TOTAL A TRANSMITIR: 7000 MW

  22. ALTERNATIVA 1: 500 KV POR EL RIO URUGUAY AMBAS CENTRALES AL LADO ARGENTINO: 2400MW 290 km Zona a ubicar un SVC 280 km 2000 MW 510km 400 km Paraná • 2700 KM LINEA 500 KV • CAPACITORES SERIES • SVC 150 km 250 km ZONA DE POSIBLE ACOMETIDA EN AREA GBA

  23. ALTERNATIVA 2: 500 KV CON UN RAMAL POR RIO PARANÁ AMBAS CENTRALES AL LADO ARGENTINO: 2400MW 290 km Zona a ubicar un SVC 280 km 2000 MW 450 km 510km Paraná 150 km • 3000 KM LINEA 500 KV • CAPACITORES SERIES • SVC 200 km 300 km 250 km ZONA DE POSIBLE ACOMETIDA EN AREA GBA

  24. ALTERNATIVA 3: TRANSMISION EN CORRIENTE CONTINUA (DC) AMBAS CENTRALES AL LADO ARGENTINO: 2400MW 290 km • 300 KM LINEA 500 KV • CAP. SERIES 2000 MW Paraná • 900 KM LINEA DE DC • TENSIÓN POSIBLE: +/-600 KV • CAPACIDAD TRANSMISIÓN ≈ 3000 MW ZONA DE POSIBLE ACOMETIDA EN AREA GBA

  25. EVACUACION GENERACION DE MENDOZA Y COMAHUE

  26. ALTERNATIVA 1: AMPLIACION DE RED DE 500 KV • (CUYO-GBA: 2 TRAMOS + 1 ET DE 500 kV) E.T. intermedia en 500/132kV. Permitirá alimentar zona perteneciente a 4 provincias Zona de posible acometida en área GBA LOS BLANCOS I y II ~ 500 MW • Otra Generación en Cuyo • Luján de Cuyo 250 MW • Otras Hidro ~300 MW TOTAL A TRANSMITIR: 7300 MW • Mar del Plata CHIHUIDO I: 637 MW CHIHUIDO II: 260 MW

  27. ALTERNATIVA 2: AMPLIACION DE RED DE 500 KV • (CUYO-GBA-LIT: 3 TRAMOS + 2 EETT DE 500 kV) ET Venado Tuerto 500kV Permitiría alimentar la zona sur de Santa Fe Zona de posible acometida en área GBA LOS BLANCOS I y II ~ 500 MW • Otra Generación en Cuyo • Luján de Cuyo 250 MW • Otras Hidro ~300 MW • Mar del Plata CHIHUIDO I: 637 MW CHIHUIDO II: 260 MW E.T. intermedia en 500/132kV GASTRE 1300 MW

  28. INGRESO DE CENTRALES CORDON DEL PLATA Y DEMANDAS EN AREA CUYO ZONA DE UBICACIÓN DE DEMANDAS MINERAS Y TREN POR TUNEL BAJA ALTURA • LINEAS DEL PLAN FEDERAL • LA RIOJA -RODEO • RODEO – SAN JUAN • Mercedes • RODEO • CALINGASTA C.H.CORDÓN DEL PLATA ~1500 MW LOS BLANCOS I 320 MW