MACBAT IV – EVC Electronic Volume Corrector - Kriti Trade Impex

MacBAT IV gas volume corrector executing PTZ conversion is a device designed to measure volume, energy, and flow of gas. It is a battery operated device with the possibility to connect the external power supply. look this MacBAT IV quotation PDF and enhance Your Knowledge skills if You want more information about this device to follow the link. <br>http://bit.ly/2JWYoGC

kimpex
Download Presentation

MACBAT IV – EVC Electronic Volume Corrector - Kriti Trade Impex

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gas MacBAT IV gas volume and energy electronic conversion device with intergrated GSM 2G or 3G modem MacBAT volume, energy and flow of gas. It is battery operated device with possibility to connect external power supply. The device converts the volume of gas counted by the gas meter (turbine, rotary, ultrasonic) into the basic conditions. Gas compressibility factor is calculated with the use of algorithms SGERG-88, MGERG-88, AGA8-92DC, AGA8-G1, AGA8-G2, AGA NX-19 mod or constant value of Relative compression factor. MacBAT IV is an intrinsically safe device ready to be installed at explosion hazard Zone 0. IV gas volume corrector executing PTZ conversion is a device designed to measure Main features of the MacBAT IV • Industrial housing cooperate with any kind of gas meter like turbine, rotary, ultrasonic directly by LF, HF, Encoder, ModBUS • 3 independent high-performance ports of the serial transmission (3xRS485 + OPTICAL INTERFACE 62056-21+ NFC IEC 14443 • Built GSM modem • Large backlit graphic display • 6 binary inputs, 2 binary NAMUR intrinsically safe inputs (working on baterry mode) • Solar battery operation mode • Second built-in pressure transducer available as an option • MacBAT IV can simultaneously co-operate with up to four external pressure or temperature transducers, gas chromatograph, external card • Can store registered values with monthly sampling interval from more than 80 years Sp. z o.o. Wspolna 19, Ignatki, 16-001 Kleosin, Poland gas@plummac.com www.plummac.com

  2. Gas Technical specification Dimensions Weight Housing material Relative humidity Ambience temperature range Housing protection class Keyboard Display Ex classification 210 x 170 x 90 mm 2,4 kg Aluminium casting max 95% at temp. 55°C -25°C up to 55°C (ATEX+MID), -40°C up to 65°C (ATEX) IP 65 (for outdoor installation) 18 pushbuttons LCD - graphic 320x240 pixels, with backlight II 1 G Ex ia IIA T4 Ga (without integrated modem) II 1 G Ex ia IIA T3 Ga (with integrated modem) - certificate 15 ATEX 0116X (EN 60079-11) Lithium battery size D 3,6V/17Ah, operating time: One battery: 6 years | Two batteries: 10 years | Three batteries: 14 years •IntrinsicallysafesupplywithtransmissioninterfaceINT-SIIRS232,RS485(11÷30VDC),INT-S3RS485 with an 2 x binary outputs • 3 independent transmission ports, speed up to 115 200 b/s: COM1, COM2, COM3 standard RS-485 • Optical Interface IEC 62056-21 • NFC interface IEC 14443 • GSM 2G 850, 900, 1800, 1900 | GSM 3G 900, 2100 MHz MODBUS RTU, ASCII, ENRON, GAZMODEM3, GAZMODEM2,GAZMODEM2 (MASTER MODE). (other protocols can be used on request) M2/E2 Internal supply External supply Transmission ports Transmission protocols Environment conditions class (Mechanical/Electromagnetic) Base conditions Fixed parameter set by manufacturer, available options: pb: 1,01325 bar, 1,01592 bar, 1,01325352987 bar (14,696 psi), 1,01559774734 bar (14,73 psi) Tb: 273,15K (0°C), 288,15K (15°C), 293,15K (20°C), 288,7055556K (60°F) T1: 298,15K (25°C), 273,15K (0°C), 288,15K (15°C), 288,7055556K (60°F) (T1 - reference temperature for combustion process) 0,5 % at reference conditions 1 % at nominal operating conditions typical error < 0,13% ECD Class A The maximum permissible error (MPE) according to standard „EN 12405-1” The maximum permissible error (MPE) according to standard „EN 12405-2” Used algorithms for calculations of compression factor Registration periods SGERG-88, MGERG-88, AGA8-92 Detailed Composition, AGA8-G1, AGA8-G2, AGA NX-19 mod constant compression factor K1 • Data registered periodically: recording interval from 1 up to 60 minutes – 19000 records • Hourly data: more than 2 years • Daily data: more than 3 years • Monthly data: more than 80 years • Events memory: approximately 2000 records Meets the requirements specified in Standard 2004/22/WE (MID) • • • • 8 digital inputs (2xLF, 1xTS, 5xIN) 2LFinputs,potentialfree,frequency0÷2Hz,reedcontact,WIEGAND Tamper protection switch (closed by default) 2HFpulsesinputs,NAMUR,frequency0÷5000HzEN60947-5-6alsocanworkingonbatterypart time; 1x ENCODER 2 Ex signalization inputs, NAMUR (shared with HF pulses input) 6 Ex signalization inputs – to cooperate with potential free junctions Pressure sensor p1 - measurement range in standard option - up to 700 kPa. The sensor is finished withmetricscrewthreadM12x1.5(Ermeto),pressureranges:90÷250/90÷1000/180÷700/400÷2000/ 1000÷10000kPa 20 °C (± 3 °C) ± 0,2 % of measured value ± 0,35 % of measured value Inputs • • • (-25÷55)°C • Thermometer Pt100 class A, 4-wire with the cable lenght compensation, diameter 5,7 mm, Maximum permissible errors for measurements of t 20 °C (± 3 °C) ± 0,08 % ± 0,13 % (-25÷55)°C • • • • - 3x configurable binary • 4 - 20 mA analog output (optional) and by using external module, 2x relay outputs Pressuresensorp2(optional)–absoluteorgauge0÷10MPa 1 analog input 0-5 V (for external pressure sensor) 2 analog inputs 4-20 mA (optional) by using external module 4 OC type digital outputs (separated): - 1x configurable - binary or frequency (0-5000Hz), Counters: Vb ,Vm , E Control outputs

  3. Gas Communication 1. Autonomous transfer of data to system – Read out of data through GPRS/GSM with the use of battery SCADA or Billing system Ex Zone 0/1 GSM/GPRS/SMS 2. Remote data read out – connection through communication interfaces INT-S II, INT-S 3, IK-301 and RTU controller independently 2x 4-20mA 4xrelay outputs Ex Zone 0/1 RS 485 RS 485 Option 1 Option 2 Extension module GPRS/GSM 2G,3G SCADA EM-1 3 RS 485 RS 485 RTU Controller Ethernet 3. Local readout and configuration OptoBTEx Optical Bluetooth Head or directly by NFC 4. Measurement scheme with MacBAT IV and Ultrasonic gas meter HF2 HF1 LF/AL Temperature measurement Ultrasonic gas meter Pressure measurement Sp. z o.o. Wspolna 19, Ignatki, 16-001 Kleosin, Poland gas@plummac.com www.plummac.com

  4. Gas 5. Measurement scheme with MacBAT IV and Turbine gas meter GSM (GPRS or SMS) Pressure monitoring after reduction 2xRS485 or ENCODER 2xHF or ENCODER+HF Temperature measurement Gas meter Pressure - reducing valve Pressure measurement Accessories of MacBAT IV INT-S 3 | Transmission interface Interface enables supply and separation of connected intrinsically safe measurement devices in stationary telemetric systems supplied from 230V mains or a battery. It is possible to transmit data to computers or other devices with battery or mains supply equipped with RS485 port. It enables data readout from devices located 1st and 2nd explosion-hazard areas. READOUT DEVICES: MacBAT IV, MacBAT III resolvers, MacBATe, MacREJII recorders, MacRP, MacR2 peak logger, MacPII/D, MacTII/D pressure and temperature transducers. EM-1 | Extension module EM-1 module is a device that extends the functionality of MacBAT IV by adding two additional current outputs operating in 4-20 mA current loop and four binary relay type outputs. The EM-1 module can also operate as a standalone device due to the fact it has own table of available parameters available for remote modification using GazModem2 or Modbus transmissions protocols. Data readout and modification can be performed with the use of SCADA system. OptoBTEx | Optogaz-bluetooth interface OptoBTEx interface is used for wireless transmission of data from devices equipped with OPTO-GAZ communication interface compatible with IEC 62056-21 standard for configuration and read out software installed mainly on mobile devices with MS Windows, Android (tablet, smartphone, laptop) operation system. OptoBTEx does not modify transferred data and wireless communication is performed in Bluetooth 2.1+EDR Class 2 standard. IK-301 | 3,5G industrial modem Transmission interface IK-301 is a device, which allows to use functionality of 2G/3,5G networks for realization of telemetric read outs. Device is adapted to be installed in telemetric boxes. Interface can operate in industrial environment conditions. It is equipped with internal and configurable by user systems of auto-control and auto- restart after detection of interruption during its operation. IK-301 interface allow to create connection in 2G/3,5G mode (TCP/IP, UDP, FTP protocols). eWebTEL | Software System eWebTEL is a platform aggregating measurement data intended for comprehensive supervision over monitored gas network. It enables to graphically visualize data sent from the resolvers, manometers and recorders, geo-location of devices. It also allows to overview history of recorded data and generation of reports concerning: monthly gas consumption along with hour peaks by particular receivers or group of receivers, history of gas consumption by particular receivers or group of receivers, failure occurrences and times, history of parameter values defining a condition of gas network. Sp. z o.o. Wspolna 19, Ignatki, 16-001 Kleosin, Poland gas@plummac.com www.plummac.com