1 / 15

6890 Flame Photometric Detector Introduction and Theory

6890 Flame Photometric Detector Introduction and Theory. August8, 2003. 6890 FPD - Top Level Assembly. Vent Tube. Back DET Temp Heater. Photo-Multiplier Tube (PMT). AUX 2 Temp Heater. 6890 FPD Installation. Vent Tube. Photo-Multiplier Tube (PMT). Signal Connection.

kerri
Download Presentation

6890 Flame Photometric Detector Introduction and Theory

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 6890 Flame Photometric DetectorIntroduction and Theory August8, 2003

  2. 6890 FPD - Top Level Assembly Vent Tube Back DET TempHeater Photo-Multiplier Tube (PMT) AUX 2 TempHeater Agilent Restricted

  3. 6890 FPD Installation Vent Tube Photo-Multiplier Tube (PMT) Signal Connection Back DET TempHeater Connection AUX 2 TempHeater Connection High Voltage Connection Ignitor Connection Agilent Restricted

  4. 6890 FLAME PHOTOMETRIC DETECTOR Flame Photometric Product No. : G2333A/G2334A or HP 6890 option 240/241 Single and Dual Signal options. EPC Only. Same design as the 5890 FPD . (Most part numbers the same) Phosphorus and Sulfur filters available. Agilent Restricted

  5. 6890 FLAME PHOTOMETRIC DETECTOR Installation: Can be retrofitted on older instruments but may require top cover modification. PMT mounted left to right Single FPD - Fitted in back position (ease of access to front) Dual FPD - Fitted in back : Uses both detector PCB slots : Cannot use ALS in back position. Uses both DETB and AUX2 heated zones to heat transfer line and heated block, but only DET temp entered. Requires AUX actuator solenoid bracket and wiring harness. Requires 2.1x 6890 firmware and 4.02 Chemstation (single) 3.0x 6890 firmware and 5.01 Chemstation (dual) Agilent Restricted

  6. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  7. 6890 FLAME PHOTOMETRIC DETECTORDual Wavelength option PhosphorusFilter SulfurFilter PMT 1 PMT 2 Jet Air/H2Lines Agilent Restricted

  8. 6890 FLAME PHOTOMETRIC DETECTORDual Wavelength option Agilent Restricted

  9. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  10. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  11. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  12. 6890 FLAME PHOTOMETRIC DETECTORPhoto Multiplier Tube Theory Photo-electron Dynodes Secondary electrons Photo-emissiveCathode Anode/Collector e - 106 DC Voltage e - Photon of Light Signal outto electrometer 850 VDC Electron Multiplication by the DynodesTypical Gain 100,000 - 1,000,000 Agilent Restricted

  13. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  14. 6890 FLAME PHOTOMETRIC DETECTOR Agilent Restricted

  15. Varian PE Shimadzu Fisons O.I. HP Agilent 3400 9000XL GC 17A 8000 5380 5890 6890 S MDL pg/sec <100 10 20 5 1 20 20 Dynamic Range 10^3 10^2 10^3 10^3 10^3 10^3 10^3 S/C Selectivity 10^3/^6 10^4 10^5 10^5 10^6 10^5 10^5 P MDL pg/sec <1 1 0.9 0.2 0.1 0.9 0.9 Dynamic Range 10^5 10^3 10^4 10^4 10^4 10^4 10^4 S/C Selectivity 10^5? 10^5 10^6 10^6 10^5 10^6 10^6 Upper temp limit 400 450 450 350 420 300 250 6890 FLAME PHOTOMETRIC DETECTOR Unique features Dual PPC Dual PMT Pulsed Dual EPC Flame H2 / air FPD PMT Also EPC HP GC one or PFPD two FPDs Dual PMT Price $11,595 $7245 $7400 Agilent Restricted

More Related