Limited Streamer Tubes for the IFR Barrel

Limited Streamer Tubes for the IFR Barrel. INFN : Ferrara, Frascati, Genova, Padova, Roma, Torino US : Ohio State, Oregon Princeton, SLAC, UCSD. Stewart Smith. Installation Review SLAC, Oct 21, 2003. The LST Team. M. Andreotti, D. Bettoni, R. Calabrese†, V. Carassiti,

kennedyjohn
Download Presentation

Limited Streamer Tubes for the IFR Barrel

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Limited Streamer Tubes for the IFR Barrel INFN: Ferrara, Frascati, Genova, Padova, Roma, Torino US: Ohio State, Oregon Princeton, SLAC, UCSD Stewart Smith Installation Review SLAC, Oct 21, 2003

  2. The LST Team M. Andreotti, D. Bettoni, R. Calabrese†, V. Carassiti, G. Cibinetto, A. Cotta Ramusino, E. Luppi, M. Negrini, L. Piemontese Ferrara University and INFN R. Baldini, A. Calcaterra, U. Denni, P. Patteri, A Zallo Laboratori Nazionali di Frascati dell’INFN R. Capra, M. Lo Vetere, S. Minatoli, S. Passaggio, C. Patrignani, E. Robutti Genova University and INFN Livermore National Laboratory C. Simani, D. Lange T. Allmendinger, K.K. Gan, K.Honscheid, H. Kagan, R. Kass, J.Morris, C. Rush, S.Smith, Q. Wong, M.Zoeller Ohio State University R. Frey, M. Lu, N. Sinev, D. Strom, J. Strube University of Oregon C. Fanin, M. Morandin, M. Posocco, M. Rotondo, R. Stroili, C. Voci Padova University and INFN J. Biesiada, G. Cavoto*, N. Danielson, R. Fernholz, Y. Lau, C. Lu, J. Olsen, W. Sands, A.J.S. Smith†, A. Telnov Princeton University S. Morganti , G Piredda, C. Voena Roma “La Sapienza”University and INFN D.B. MacFarlane, H.P. Paar University of California at San Diego R. Boyce , R. Convery, C. Hast, P. Kim, J. Krebs , R. Messner, M. Olson , R. Schindler, Z. Szalata , T. Weber , W. Wisniewski, C. Young Stanford Linear Accelerator Center Engineers † Contact persons * Also INFN Rome Installation Review

  3. IFR Barrel Performance: Pion fake rate vse(m) Simple muon selector -- uses only lint info. (neural net algorithms improve rejection by factor ~2) Design June 2002 LSTs Only LSTs + Brass pm > 2 Gev/C Muon Efficiency (Monte Carlo) Installation Review

  4. LST design • Single-layer large cell (15x17 mm) • Readout of x and y coordinates from outside strips Graphite- Coated PVC Installation Review

  5. Module Assembly Plan • Ohio Stateand Princeton preparing facilities for module assembly. • Both universities fabricating parts for assembly fixtures. • Shipping and testing boxes are being designed. • Planning for testing and quality control is in progress. • Installation procedures coordinated by SLAC and Princeton engineers. Installation Review

  6. Efficiency with cosmic ray trigger Full-scale prototype (Identical to “Test Tube” in BaBar) > 400 volt plateau Efficiency limited to < 100% By geometry Ternary [ZEUS] Gas, 8% Isobutane Installation Review

  7. Quality Control • Absolutely crucial to get this right! • Q/C procedures at Pol.Hi.Tech. (PHT) • Test equipment supplied by INFN has been accepted by PHT. • Tube acceptance criteria agreed upon – Stated in PO. • Procedures and equipment in place by end of October. • Q/C and long term test procedures at US sites has been designed. • INFN/DoE/NSF student exchange program! • Two Princeton students will be at PHT from Oct 15 to Dec 15. • They will then travel west with the LST’s. Installation Review

  8. Milestones • Dec 15 ’03 -- BaBar chooses LST for IFR Upgrade • June 12 -- EPAC Review Approves LST Proposal • June 15 -- Cost/Schedule/WBS prepared • June 22 -- INFN Gruppo Uno Evaluation • June 27 -- BaBar IFC Approves Project • June 30 -- Large/Small Cell Decision • July 17 -- Electronics Design Review • Aug 1 -- Place Orders for Tubes • Aug 26 -- Review of Q/C plans • August 27 -- Install Test Module into BaBar • Oct 1 -- Place all orders for “small parts” • Oct 31 Place orders for components: electronics, crates, HV system, signal cables, HV cables • Place orders for crates • Nov 3 -- Production begins! • Begin fabrication of shipping boxes • Dec 18 -- First shipment (~5%) of tubes to Princeton/OSU • -- First Phi strips arrive in Princeton/OSU Installation Review

  9. Milestones (cont’d) • Jan 10 ’04 Q/C systems operational at OSU, Princeton • Feb 1 HV system shipped to Princeton • March 1 Crates complete • March 1 Electronics tests begin • March 15 5% of modules shipped to SLAC • March 15 Q/C system operational at SLAC • Feb 15 1/3 of tubes, phi strips shipped to Princeton/OSU • April 1 Electronics complete • April 1 Production, Q/C complete at PHT • April 1 Gas system assembled, under test at SLAC • April 15 Electronics, crates, HV shipped to SLAC • May 1 5 Ship Modules for 2 sextants to SLAC • June 1 Q/C begins at SL:AC • July 20 Modules for last 4 sextants assembled at OSU, Princeton • July 31 LST system construction complete • Aug 1 Installation of 2 sextants begins • ~Oct 1 Installation of 2 sextants complete • July 2005 Install remaining 4 sextants (ready earlier) Installation Review

  10. Milestones Installation Review

  11. Milestones (cont’d) Backup Slides Installation Review

  12. General Infrastructure for Q/C • QC data and other relevant information collected by hand or, whenever possible, automatically with several DAQ stations. • Common systems at PHT, Princeton, OSU, and SLAC. • Labview will be used to write the DAQ software and design the interface. • The DAQ stations will be operated by physicists on shift and/or PHT personnel. • All DAQ stations will be on a wireless LAN. • The DAQ station output will be simple text files. • Local production database will be available on site. • Data files will be transferred every day to an outside server to be imported in the official offsite LST database. Installation Review

  13. Summary • R &D and Prototyping Complete – It works! • Aging and Rates • Noise • Mechanical Stability • Tolerances, Surface quality • Test Tube operating successfully in BaBar • Most orders placed, rest by end of month • Production Starts in 2 Weeks • Group is devoting huge effort and resources on Q/C • We have implemented tests to identify all known diseases. • These tests spotted many problems with prototypes. • On schedule for Aug 1 2004 Installation Installation Review

  14. Backup Slides Installation Review

  15. Scope of Q/C Activities at PHT • Barcode labelling • Inspection of profiles • Mechanical • Graphite coating • Resistivity Measurement • Inspection of jackets, endcaps, circuit cards • Gas tightness (leak test) • Wire check • Wire-cathode distance measurement • HV conditioning and plateau measurement • Long range tests Installation Review

More Related