1 / 55

مشروع إعتماد معمل الكمياء الإكلينيكيه – مستشفى الطوارئ

مشروع إعتماد معمل الكمياء الإكلينيكيه – مستشفى الطوارئ. Prof/ Azza abd al baky. Role of clinician in lab result accuracy. Introduction. Three phases of laboratory testing: pre-analytical, analytical and post-analytical

kelly-cox
Download Presentation

مشروع إعتماد معمل الكمياء الإكلينيكيه – مستشفى الطوارئ

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. مشروع إعتماد معمل الكمياء الإكلينيكيه – مستشفى الطوارئ

  2. Prof/Azzaabd al baky Role of clinician in lab result accuracy

  3. Introduction • Three phases of laboratory testing: pre-analytical, analytical and post-analytical • Pre-analytical—specimen collection, transport and processing • Analytical—testing • Post-analytical—testing results transmission, interpretation, follow-up, retesting.

  4. Pre-analytical errors • Pre- and post-analytical errors are estimated to constitute 90% of errors • Errors at any stage of the collection, testing and reporting process can potentially lead to a serious patient misdiagnosis • Errors during the collection process are not inevitable but can be prevented with a diligent application of quality control, continuing education and effective collection systems.

  5. The steps of the preanalyticalphase Preparation prior to sampling Sampling/handling Storage/transport Preparation prior to analysis

  6. Implications of errors • and compromise the diagnosis and treatment of the patient • Errors made in the period prior to the analysis of the sample ... • may influence the quality of the final measured results ... No result is better than bad result

  7. Complex and labor intensive • The more steps involved in a process, the more likely there will be errors committed • 32 - 75% of all test errors occur in the preanalytical phase Stankovic 2008 “Quality Improvements in the Preanalytical Phase: Focus on Urine Specimen Workflow”

  8. Effects of Pre-analytical Variables on the Quality of Laboratory Testing • Paying close attentionto the preanalyticalvariables associated with blood collection iscriticalin ensuring accurate testresults in all areas of the clinical laboratory.

  9. The Pre-Analytical process • Patient Identification • Sampling Technique • Test Collection Procedures • Specimen Transport • Specimen Processing

  10. The Pre-Analytical process Collect Sample: • Locate Patient • Prep Patient • Draw Sample • Label • Dispose of supplies

  11. Patient identification When identifying the patient, have them provide their full name, address, identificationnumberand/or date of birth. Hospital No inpatients should be wearing an identification band with the above information, which the phlebotomist should confirm before the venipuncture.

  12. Effects of Pre-analytical Variables on the Quality of Laboratory Testing • Patient Identification:It is important to identify a patient accurately so that blood is collected from the correct person. Drawing blood from the wrong person, or labeling the correct patient’s sample with a different patient’s label can certainly contribute to laboratory error. (Mislabeling ???)

  13. Factor affecting lab result • Some patient variables that affect test results Age Genetic variation Gender Nutrition status Diet Diagnostic and therapeutic Drugs procedures(PR&endoscopy) Exercise Obesity Posture Biorythm Haemolysis,lipemia Special habits & icterus

  14. Test Collection • Timing of Collection • Therapeutic Drug Monitoring • Peak and trough collection times • Basal State Collections • Fasting requirements—no food or liquid except water(10-12h) • 2h postprandial, from the start of food . • Specimens affected by time of day, for example, cortisol, iron and TSH.

  15. Phlebotomy • Phlebotomy is a highly complex skill requiring expert knowledge, and critical judgment • venipuncture is a frequent medical procedure. • Phlebotomy errors may cause harm to patients or result in needle stick injury to the phlebotomist

  16. Error Prevention • Phlebotomy Education • Phlebotomists should have completed a standard academic course in phlebotomy and undergo thorough on-the-job training under the supervision of a senior phlebotomist • Continuing Education • Phlebotomists should participate in regular educational competency assessments (written and observational) • Professional Licensure • Phlebotomy Staffing • Adequate staffing to maintain collection standards • Technology • Use of barcode scanners for patient identification

  17. 1-posture: The patient should be comfortably seated or supine for 20 minutes before sampling.Not standing The patient arm should be extended in a straight line from the shoulder to the wrist. 2-collection site. The median cubital vein is the preferred site. Veins on the hand or at ankle may be used. Avoid the arm with: Extensive scarring or hematoma .,infection , edema ,burn , Containing I.V. access for I.V. infusion. On the side of mastectomy.

  18. Phlebotomy Technique • Correct collection system • Evacuated tube system (Vacutainer) for large veins in antecubital fossa • Syringe for small, fragile veins or veins outside antecubital fossa • Venous access • Needle entry should be at 15 to 30 degrees depending on depth of vein • Needle entry should be in same direction as vein, centered over vein • Anchor vein to prevent movement during needle entry and to reduce pain to patient

  19. Phlebotomy Technique Errors • Tourniquet Application • Tourniquet tied too close to the venipuncture site can cause hematoma • Veins may not become prominent if tourniquet is tied too high (more than 3 to 4 inches above venipuncture site) • Tourniquet left on longer than one minute can result in hemoconcentration, affecting some test results • Tourniquet should be released as soon as needle is in the lumen of the vein and blood flow established

  20. Phlebotomy Technique • Cleansing of venipuncture site • Thorough cleaning with alcohol • Allow alcohol to dry completely to avoid stinging sensation upon needle entry and hemolysis of sample • Samples such as blood cultures should be collected using iodine to cleanse site to ensure sterility of sample • Recollection rate for blood cultures ranges due to contamination is as high as 50% in hospitals with increased costs, patient overtreatment

  21. Test Collection • Additive : EDTA,citrat, lithium heparin ,oxalate,flourid • Hemolysis • Blood collected insufficient to amount of additive in tube, • Traumatic venipuncture • Blood collected from area with hematoma • Vigorous shaking of tubes after collection • Milking the site when collecting capillary samples and blood collected using a small diameter needle.

  22. Test Collection • Capillary Collections—finger stick or heel stick • Appropriate site • Heel stick—sides of the bottom surface of the heel • Finger stick—third or fourth fingers, perpendicular to fingerprint lines on fleshy pads on finger surface • Warming—Warm before collection to increase capillary blood flow near skin surface • Cleaning—cleanse site with alcohol and allow to air dry • Discard first drop of blood.

  23. Recommended order of draw (NCCLS): • Blood Culture Bottles (Aerobic-Anaerobic) • Coagulation Tube • Serum Tube with or without clot activator, with or without gel separator • Heparin Tube with or without gel plasma separator • EDTA • Glycolytic Inhibitor

  24. Correct Specimen Volume: All blood collection tubes need to be filled to the correct volume. This will ensure the proper amount of blood for the amount of additive in the tube (blood to additive ratio). For example, if a 5 mL draw heparin tubeis only filled with 3 mL of blood, the heparin concentration is erroneously high and may potentially interfere with some chemistry analytes, tube for Coagulation Studies incomplete filling results in specimen dilution and erroneous Prothrombin and aPTT test results.

  25. Proper Tube Mixing:All tubes with additives need to be inverted to mix the additive evenly with the blood. Impropermixing of the tube after venipuncture could contribute to sample clotting.

  26. E) Specimen transport Temperature Light

  27. Transport Errors • Temperature • Specimens must be transported at the appropriate temperature for the required test • On ice—ABGs, Ammonia • Warmed -- (37 C), cryoglobulins • Avoid temperature extremes if transported via vehicle from other collection site • Transport Container • Some samples need to be protected from light, for example, bilirubin • Transport in leak-proof plastic bags in lockable rigid containers ,avoid agitation.

  28. Blood Specimen Transport • Transport of blood specimens in the proper manner after collection ensures the quality of the sample • Timing • Some specimens must be transported immediatelyafter collection, for example Arterial Blood Gases. • Specimens for serum or plasma chemistry testing should be centrifuged and separated within two hours

  29. Special Handling of Blood Specimens:Certain chemistry analytes will require the tube of blood to be chilled after collection in order to maintain the stability of the analyte. A slurry of ice and water is recommended for chilling the tubes of blood. Examples : adrenocorticotropic hormone (ACTH), angiotensin converting enzyme (ACE), acetone, ammonia, catecholamines, free fatty acids, lactic acid, pyruvate and renin ,PTH

  30. Blood gases analysis “Collection of a blood specimen, as well as its handling and transport, are key factors in the accuracy of clinical laboratory analysis and ultimately in delivering quality patient care” ”Arterial blood is one of the most sensitive of the specimens sent to the clinical laboratory for analysis” ”Blood gas and pH analysis has more immediacy on patient care than any other laboratory determination” ”In blood gas and pH analysis an incorrect result can often be worse for the patient than no result at all”

  31. What is so special about blood gases? • NOT like other blood samples • STAT parameters • Short Turn Around Time • Must be analyzed within a short time • pO2, pCO2, pH, LAC, GLU • Valuable results right now • Not in one hour • Sample composition changes • Patient status changes

  32. Some points to keep in mind - sampling from A-lines Preparation prior to sampling • Label the sampler with patient ID • Use dry electrolyte balanced heparin • Endeavor to keep the patient’s respiratory condition stable for a certain period prior to sampling • Make sure that the a-line has been adequately cleared of flush solution • Aspirate the sample slowly to prevent degassing and hemolysis • Expel any air bubbles immediately after sampling • Mix the sample thoroughly with heparin after sampling Sampling/handling

  33. Analyze sample immediately • If storage is unavoidable, store the sample at room temperature for max. 30 min. Samples with expected high pO2 values should be analyzed within 5 min. Storage/transport • Before transferring the sample into the analyzer mix thoroughly • Visually inspect the sample for clots and air bubbles • Enter patient ID in analyzer logs Preparation prior to sample transfer

  34. Stabilization of the respiratory condition • To get a true picture of the patient’s respiratory condition the patient should ideally be in a steady state of ventilation • Patients should be at rest for 5 min • Ventilatory settings should be unchanged for 20 min • Pain and anxiety from arterial puncture may influence the steady state of respiration and should thus be minimized

  35. Storage recommendations General storage recommendation Do not cool the sample Analyze within 30 minutes For samples with high pO2 Analyze within 5 minutes For special studies, e.g. shunt Analyze within 5 minutes For samples with high leukocyte or platelet count Analyze within 5 minutes Expected delayed analysis When analysis is expected to be delayed for more than 30 minutes, the use of glass syringes and storage in ice slurry is recommended • Storage and transport time should be kept at a minimum • Volatile nature of gases • Continued metabolism in blood • For parameter panels including GLU/LAC, be aware that 30 minutes storage might lead to biased results • It is recommended by the NCCLS to avoid cooling of samples when kept in plastic

  36. Continued cellular metabolism in sample pO2 since oxygen will still be consumed pCO2 since carbon dioxide will still be produced pH primarily due to the change in pCO2 and glycolysis cCa2+ since the change in pH will influence the binding of Ca2+ to protein cGlu since glucose will be metabolized cLac due to glycolysis

  37. Slowing down the metabolism pO2 • Blood gas samples in glass samplers can be cooled • Storing the sample at a lower temperature (0-4 °C) will slow down the metabolism by at least a factor of 10 [NCCLS] • Cool samples in an ice slurry or other suitable coolant • Never store the samples directly on ice as this causes hemolysis of the blood cells Time 0-4 C 25 C NCCLS Document C27-A; Blood Gas Pre-Analytical Considerations: Specimen Collection, Calibrations and Controls; Approved Guideline

  38. Potential preanalytical errors Preparation prior to sampling • Missing or wrong patient/sample identification • Use of the wrong type or amount of anticoagulant • - dilution due to the use of liquid heparin • - insufficient amount of heparin • - binding of electrolytes to heparin • Inadequate stabilization of the respiratory condition of the patient • Inadequate removal of flush solution in a-lines prior to blood collection

  39. Sampling /handling • Mixture of venous and arterial blood during puncturing • Air bubbles in the sample • Insufficient mixing with heparin • Incorrect storage • Hemolysis of blood cells Storage and transport • Visually inspect the sample for clots • Inadequate mixing of sample before analysis • Failure to identify the sample upon analysis Prep prior to transfer

  40. Mixture of venous and arterial blood • When puncturing an artery it is important not accidentally to get the arterial blood mixed with venous blood • This may, for instance, occur, if you hit a vein before locating the artery • Even an admixture of a small amount of venous blood may significantly bias the results • This is especially true of pO2 and sO2, but other parameters may also be affected Vein Artery 40 mmHg / 5.3 kPa 100 mmHg / 13.3 kPa

  41. Mixture of venous and arterial blood • In arteries the blood pressure is high enough to fill a self-filling syringe • If a self-filling syringe does not fill it may be because a vein has been hit • In that case a new sample should be taken Vein: Pressure rarely> 10 mmHg Artery: Systolic bloodpressure normally> 100 mmHg

  42. Inadequate removal of flush solution • Flush solutions used in a-lines must be removed completely from the system to avoid a dilution of the blood sample • It is recommended to withdraw a volume equal to three to six times the “dead space” of the catheter system (NCCLS)

  43. Inadequate removal of flush solutions • Sample B and A are both a-line samples taken from the same patient immediately after each other • Before taking sample B only 1 mL of saline solution was removed - the tubing, however, looked red • Before taking sample A saline solution was removed as recommended Sample A ctHb 6.2 mmol/L cGlu 9.6 mmol/L cK+ 3.8 mmol/L cNa+ 130 mmol/L cCa2+ 1.00 mmol/L cCl- 101 mmol/L pH 7.271 pCO2 50.5 mmHg / 6.7 kPa pO2 116.7 mmHg / 15.56 kPa Sample B ctHb 4.6 mmol/L cGlu 6.9 mmol/L cK+ 2.5 mmol/L cNa+ 137 mmol/L cCa2+ 0.61 mmol/L cCl- 113 mmol/L pH 7.275 pCO2 35.9 mmHg / 4.8 kPa pO2 129.3 mmHg / 17.2 kPa

  44. Air bubbles • Any air bubbles in the sample must be expelled as soon as possible after the sample has been drawn • before mixing the sample with heparin • before any cooling of the sample • Even small air bubbles may seriously affect the pO2 value of the sample, normally resulting in increased values • An air bubble whose relative volume is 0.5 to 1.0 % of the blood in the syringe is a potential source of a significant error

  45. Effect of air bubbles - an example • Sample A and B were taken from the same patient immediately after each other • Sample A without air bubbles was analyzed immediately after collection • 100 µL air was added to sample B (1 mL). It was stored cold (0-4 °C) for 30 minutes and mixed for 3 minutes before sample analysis Sample A pO2 288.6 mmHg / 38.5 kPa (FIO2 1.000) Sample B pO2 253.3 mmHg / 33.8 kPa (FIO2 1.000)

  46. Insufficient mixing with heparin • Insufficient mixing can cause coagulation of the sample • It is recommended to mix the blood sample thoroughly with heparin • Invert the syringe 10 times and roll it between your palms

  47. Inadequate mixing - an example • Sample A and B were taken from the same patient immediately after each other and stored cold for 10 minutes • Sample A was mixed in a rotator (14 revolutions/min) for 3 minutes • Sample B was mixed in a rotator (14 revolutions/min) for 1 minute Sample A ctHb 6.2 mmol/L Sample B ctHb 4.5 mmol/L

  48. The blood cells are relatively fragile, and therefore hemolysis may easily occur during blood sampling Hemolysis may, for instance, occur due to high filling pressure through a narrow entrance (e.g. during too vigorous sample aspiration, sample transfer to the analyzer, etc.) vigorous rubbing or squeezing of the skin during capillary sampling too vigorous mixing of the sample cooling down the sample below 0 °C Hemolysis of blood cells