Discussion for QC steps Leak & Pop Spacers. As discussed in the previous meeting, we upload 13 gaps in the database. 30 gaps with  RE4/2 types with Batch 12 HPLs. D estroyed ~ 20 gaps to investigate the inside oil condition. P roblem !

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha

Download Presentation

As discussed in the previous meeting, we upload 13 gaps in the database.

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


As discussed in the previous meeting we upload 13 gaps in the database

Discussion for QC steps

Leak & Pop Spacers

As discussed in the previous meeting, we upload 13 gaps in the database.

30 gaps with RE4/2 types with Batch 12 HPLs.

Destroyed ~ 20 gaps to investigate the inside oil condition.

Problem !

In the test step for leak & pop spacers test, the current rejection limits seem to be too tight. We have to take into account pressure & temperature variation of the test laboratory. The pressure measured by the sensor is the gauge pressure p – p0, NOT absolute pressure.

1. Variation of p0 outside

2. Variation of T of air inside the gap

∆T = 0.1o during the 10 minutes causes a pressure variation ~ 0.33 hPa.

0.2 hPa would be an uncontrollable amount.   

The proper rejection limits seem to be

RE4/2 TW: 0.3 hPa, RE4/2 TN: 0.3 hPa, RE4/2 B: 0.4 hPa

RE4/3 TW: 0.3 hPa, RE4/3 TN: 0.4 hPa, RE4/3 B: 0.5 hPa


As discussed in the previous meeting we upload 13 gaps in the database

RE4/2 bottom (large gaps)

KODEL-TEST-RE4-2-B004

KODEL-TEST-RE4-2-B005

KODEL-TEST-RE4-2-B006

KODEL-TEST-RE4-2-B007

KODEL-TEST-RE4-2-B008

KODEL-TEST-RE4-2-B009

KODEL-TEST-RE4-2-B010


As discussed in the previous meeting we upload 13 gaps in the database

KODEL-TEST-RE4-2-TW004

KODEL-TEST-RE4-2-TW006

RE4/2 Top wide

(small gaps)

KODEL-TEST-RE4-2-TN004

KODEL-TEST-RE4-2-TN005

RE4/2 Top narrow

(mid-sized gaps)

KODEL-TEST-RE4-2-TN006

KODEL-TEST-RE4-2-TN008