Selection of Rankine Cycles for Various Resources

Selection of Rankine Cycles for Various Resources. P M V Subbarao Professor Mechanical Engineering Department. Match the Cycle and Resource …. Pressurised Water Reactor (PWR).

kelda
Download Presentation

Selection of Rankine Cycles for Various Resources

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Selection of Rankine Cycles for Various Resources P M V Subbarao Professor Mechanical Engineering Department Match the Cycle and Resource …

  2. Pressurised Water Reactor (PWR) • Over 60% of all installed commercial reactors are pressurised water reactors and like 85% of all reactors they use enriched Uranium as the fuel. • The use of enriched fuel means that a higher power density is achievable in the core and thus better efficiency. • PWR reactors use a two stage heat transfer system with ordinary (light) water acting as both a moderator and the coolant in the primary circuit. • The water in the primary circuit reaches a temperature of about 325°C and must be at very high pressures, so that it can not boil. • It gives up its heat in a second heat exchanger which produces the steam in the turbine circuit based on the Rankine cycle. • Typical output power is 1000MW with a system efficiency of 33%.

  3. Progress in Rankine Cycle

  4. Optimal Design of Vapour Power Plant

  5. Thermal Model of A Steam Condenser Hot Well

  6. Energy Balance of A Condenser • Energy balance: • The temperature rise of cooling water: • 6 to 7 degree C for single pass. • 7 to 9 degree C for double pass. • 10 to 12 degree C for four pass.

  7. Qin Wnet Tc

  8. Effect of inlet steam pressure (P) and condenser pressure on Rankine efficiency with constant inlet steam temperature of 470o C

  9. Power Loss Due to Excess Back Pressure

  10. Further Developments in Carnotization of Rankine Model BY P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Suppression of Non-Isothermal Heat Addition Zones…..

  11. Reassessment Thru Carnot Model 4500C 3110C ~2500C