1 / 25

ITU-T Study Group 5 Publications

ITU-T Study Group 5 Publications. Greg Jones ITU Telecommunication Standardization Bureau greg.jones@itu.int. ITU-T Study Group 5. “Protection against electromagnetic environment effects”. Handbooks Directives ITU-T K-series Recommendations. Guide to the use of ITU-T SG5 Publications ….

kalil
Download Presentation

ITU-T Study Group 5 Publications

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ITU-T Study Group 5Publications Greg Jones ITU Telecommunication Standardization Bureau greg.jones@itu.int

  2. ITU-T Study Group 5 “Protection against electromagnetic environment effects” • Handbooks • Directives • ITU-T K-series Recommendations

  3. Guide to the use of ITU-T SG5 Publications … • 1 Scope and objective • 2 Terminology and abbreviations • 2.1 Terminology • 2.2 Abbreviations • 3 Reference configuration • 4 Electromagnetic compatibility requirements for telecommunication equipment and installations • 4.1 General • 4.2 EMC requirements for telecommunication equipment and installations in telecommunication centres and at radio installations • 4.3 EMC requirements for telecommunication equipment and installations a outdoor locations • 4.3.1 Telecommunication equipment • 4.3.2 Telecommunication lines • 4.4 EMC requirements for telecommunication equipment used at customer premises • ANNEX - Title and abstract of ITU-T Recommendations of the K-series and other relevant Publications

  4. Scope and responsibilities of the guide

  5. radio outdoor location installation fibre or equipment metallic line customer premises T0507610-97 telecommunication centre Reference configuration

  6. Locations • Equipment (Table 1) • Telecommunication centres • Radio installations • Outdoor locations • Telecommunication lines (Table 2) • Outdoor locations • Equipment (Table 3) • Customer premises

  7. Phenomena relating to equipment • Power supply effects • Safety, resistability, immunity, mitigation • High frequency effects • Immunity, mitigation, Emmission • EFT – Electrical Fast Transient • Resistability, immunity • Lightning • Resistability, immunity • ESD – Electrostatic Discharge • Resistability, immunity

  8. Phenomena relating to telecommunication lines • Power supply effects and low frequency interference • safety, resistibility, immunity • High frequency induction • immunity, mitigation, emission • Lightning • resistibility, protection

  9. Phenomena relating to customer equipment • Power supply effects • resistability, immunity, mitigation • High frequency effects • Immunity, emission • EFT – Electrical Fast Transient • Resistability, immunity • Lightning • Resistability, immunity • ESD – Electrostatic Discharge • Immunity

  10. Types and subjects of publications • Basic • general, Calculation/estimation, testing/measuring • Generic • Protection or mitigation • Overhead pairs, buried cable with metal pairs, optical fibre cable • Safety

  11. ITU-T SG5 Handbooks • Earthing of Telecommunication Installations (1976) • Guide to the use of ITU-T SG5 Publications • Interference Measurement Techniques (2002) • The Protection of Telecommunication Lines and Equipment Against Lightning Discharges • Chapters 1 to 5 (1974) • Chapters 6, 7 and 8 (1978) • Chapters 9 and 10 (1994)

  12. Directives Directives Concerning the Protection of Telecommunication Lines against Harmful Effects from Electric Power and Electrified Railway Lines Vol I Design, construction and operational principles of telecommunication, power and electrified railway facilities Vol II Calculating induced voltages and currents in practical cases Vol III Capacitive, inductive and conductive coupling: physical theory and calculation methods Vol IV: Inducing currents and voltages in electrified railway systems Vol V Inducing currents and voltages in power transmission and distribution systems Vol VI Danger and disturbance Vol VII Protective measures and safety precautions Vol VIII Protective devices Vol IX Testing methods and measuring apparatus

  13. Examples of ITU-T K-Series Recommendations Human exposure to EMF • K.52 (02/00) Guidance on complying with limits for human exposure to electromagnetic fields Resistability • K.20 (02/00) Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents • K.21 (10/00) Resistibility of telecommunication equipment installed in customer's premises to overvoltages and overcurrents • K.44 (02/00) Resistibility tests of telecommunication equipment exposed to overvoltages and overcurrents – Basic Recommendation • K.45 (02/00) Resistibility of access network equipment to overvoltages and overcurrents

  14. ITU-T K-Series Recommendations approved in July 2003 K.20 Resistibility of Telecommunication Equipment installed in a Telecommunications Centre to Overvoltages and Overcurrents K.21 Resistibility of Telecommunication Equipment installed in Customer Premises to Overvoltages and Overcurrents K.34 Classification of electromagnetic environmental conditions for telecommunication equipment - Basic EMC Recommendation K.43 Immunity Requirements for Telecommunication Equipment K.44 Resistibility tests for Telecommunication Equipment exposed to overvoltages and overcurrents - Basic Recommendation K.45 Resistibility of Telecommunication Equipment installed in the Access and Trunk Networks to Overvoltages and Overcurrents K.46 Protection of Telecommunication Lines using Metallic Symmetric Conductors against Lightning Induced Surges K.48 EMC requirements for each telecommunication Equipment - product family recommendation

  15. Recently approved ITU-T K-Series Recommendations • K.56 Protection of radio base stations against lightning discharges • K.58 EMC, Resistibility and Safety Requirements and Procedures for Co-located Telecommunication Installations • K.59 EMC, Resistibility and Safety Requirements and Procedure for Connection to Unbundled Cables • K.60 Emission limits and test methods for Telecommunication Networks

  16. ITU-T K-Series Recommendations under approval • K.57 Protection Measures for Radio Base Stations sited on Power Line Towers • K.61 Guidance to measurement and numerical prediction of electromagnetic fields for compliance with human exposure limits for telecommunication installations AAP Review period ends 5 September 2003

  17. ITU-T K-Series Recommendations • The following slides are included for reference only and do not form part of the presentation

  18. K-series Recommendations K.5 Joint use of poles for electricity distribution and for telecommunications K.6 Precautions at crossings K.7 Protection against acoustic shock K.8 Separation in the soil between telecommunication cables and earthing system of power facilities K.9 Protection of telecommunication staff and plant against a large earth potential due to a neighbouring electric traction line K.10 Low frequency interference due to unbalance about earth of telecommunication equipment K.11 Principles of protection against overvoltages and overcurrents

  19. K-series Recommendations K.12 Characteristics of gas discharge tubes for the protection of telecommunications installations K.13 Induced voltages in cables with plastic-insulated conductors K.14 Provision of a metallic screen in plastic-sheathed cables K.15 Protection of remote-feeding systems and line repeaters against lightning and interference from neighbouring electricity lines K.17 Tests on power-fed repeaters using solid-state devices in order to check the arrangements for protection from external interference K.18 Calculation of voltage induced into telecommunication lines from radio station broadcasts and methods of reducing interference K.19 Joint use of trenches and tunnels for telecommunication and power cables

  20. K-series Recommendations K.20 Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents K.21 Resistibility of telecommunication equipment installed in costumer's premises to overvoltages and overcurrents K.22 Overvoltage resistibility of equipment connected to an ISDN T/S bus K.23 Types of induced noise and description of noise voltage parameters for ISDN basic user networks K.24 Method for measuring radio-frequency induced noise on telecommunications pairs K.25 Protection of optical fibre cables K.26 Protection of telecommunication lines against harmful effects from electric power and electrified railway lines

  21. K-series Recommendations K.27 Bonding configurations and earthing inside a telecommunication building K.28 Characteristics of semi-conductor arrester assemblies for the protection of telecommunications installations K.29 Coordinated protection schemes for telecommunication cables below ground K.30 Positive temperature coefficient (PTc) thermistors K.31 Bonding configurations and earthing of telecommunication installations inside a subscriber's building K.33 Limits for people safety related to coupling into telecommunications system from a.c. electric power and a.c. electrified railway installations in fault conditions

  22. K-series Recommendations K.34 Classification of electromagnetic environmental conditions for telecommunication equipment - Basic EMC Recommendation K.35 Bonding configurations and earthing at remote electronic sites K.36 Selection of protective devices K.37 Low and high frequency EMC mitigation techniques for telecommunication installations and systems - Basic EMC Recommendation K.38 Radiated emission test procedure for physically large systems K.39 Risk assessment of damages to telecommunication sites due to lightning discharges K.40 Protection against LEMP in telecommunications centres

  23. K-series Recommendations K.41 Resistibility of internal interfaces of telecommunication centres to surge overvoltages K.42 Analytical method to calculate visibility statistics for non-geostationary satellite orbit satellites as seen from a point on the Earth's surface K.43 Immunity requirements for telecommunication equipment K.44 Resistibility of telecommunication equipment to overvoltages and overcurrents K.45 Resistibility of access network equipment to overvoltages and overcurrents K.46 Protection of telecommunication lines using metallic symmetric conductors against lightning induced surges K.47 Protection of telecommunication lines using metallic conductors against direct lightning discharges

  24. K-series Recommendations K.48 EMC requirements for each telecommunication network equipment - Product family Recommendation K.49 Test condition and performance criteria for voice terminal subject to disturbance from digital mobile phone K.50 Safe limits of operating voltages and currents for telecommunication systems powered over the network K.51 Safety criteria for telecommunication equipment K.52 Guidance on complying with limits for human exposure to electromagnetic fields K.53 Values of induced voltages on telecommunication installations to establish telecom and a.c. power and railway operators responsibilities

  25. K-series Recommendations K.54 Conducted immunity test method and level at fundamental power frequencies K.55 Overvoltage and overcurrent requirements for insulation displacement connectors (IDC) terminations K.56 Protection of radio base stations against lightning discharges K.58 EMC, resistibility and safety requirements and procedures for co-located telecommunication installations K.59 EMC, resistibility and safety requirements and procedure for connection to unbundled cables K.60 Emission limits and test methods for telecommunication networks